1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
|
nvme-admin-passthru(1)
======================
NAME
----
nvme-admin-passthru - Submit an arbitrary admin command, return results
SYNOPSIS
--------
[verse]
'nvme-admin-passthru' <device> [--opcode=<opcode> | -o <opcode>]
[--flags=<flags> | -f <flags>] [-rsvd=<rsvd> | -R <rsvd>]
[--namespace-id=<nsid>] [--cdw2=<cdw2>] [--cdw3=<cdw3>]
[--cdw10=<cdw10>] [--cdw11=<cdw11>] [--cdw12=<cdw12>]
[--cdw13=<cdw13>] [--cdw14=<cdw14>] [--cdw15=<cdw15>]
[--data-len=<data-len> | -l <data-len>]
[--metadata-len=<len> | -m <len>]
[--input-file=<file> | -i <file>]
[--read | -r ] [--write | -w]
[--timeout=<to> | -t <to>]
[--show-command | -s]
[--dry-run | -d]
[--raw-binary | -b]
[--prefill=<prefill> | -p <prefill>]
DESCRIPTION
-----------
Submits an arbitrary NVMe admin command and returns the applicable
results. This may be the simply the commands result and status, or may
also include a buffer if the command returns one. This command does no
interpretation of the opcodes or options.
The <device> parameter is mandatory and may be either the NVMe character
device (ex: /dev/nvme0), or a namespace block device (ex: /dev/nvme0n1).
On success, the returned structure (if applicable) may be returned in
one of several ways depending on the option flags; the structure may
printed by the program as a hex dump, or may be returned as a raw buffer
printed to stdout for another program to parse.
OPTIONS
-------
-o <opcode>::
--opcode=<opcode>::
The NVMe opcode to send to the device in the command
-f <flags>::
--flags=<flags>::
The NVMe command flags to send to the device in the command
-R <rsvd>::
--rsvd=<rsvd>::
The value for the reserved field in the command.
-n <nsid>::
--namespace-id=<nsid>::
The value for the ns-id in the command.
--cdw[2-3,10-15]=<cdw>::
Specifies the command dword value for that specified entry in
the command
-r::
--read::
-w::
--write::
Used for the data-direction for the command and required for
commands sending/receiving data. Don't use both read and write
at the same time.
-i <file>::
--input-file=<file>::
If the command is a data-out (write) command, use this file
to fill the buffer sent to the device. If no file is given,
assumed to use STDIN.
-l <data-len>::
--data-len=<data-len>::
The data length for the buffer used for this command.
-m <data-len>::
--metadata-len=<data-len>::
The metadata length for the buffer used for this command.
-s::
--show-cmd::
Print out the command to be sent.
-d::
--dry-run::
Do not actually send the command. If want to use --dry-run option,
--show-cmd option _must_ be set. Otherwise --dry-run option will be
_ignored_.
-b::
--raw-binary::
Print the raw returned buffer to stdout if the command returns
a structure.
-p::
--prefill::
Prefill the buffer with a predetermined byte value. Defaults to 0.
This may be useful if the data you are writing is shorter
than the required buffer, and you need to pad it with a known
value. It may also be useful if you need to confirm if a device
is overwriting a buffer for a data-in command.
EXAMPLES
--------
* The following will run the admin command with opcode=6 and cdw10=1, which
corresponds to an identify controller command. This example requires the
data-len param be 4096, which is the size of the returned structure. The -r
option is used because it is a data-in command
+
------------
# nvme admin-passthru /dev/nvme0 --opcode=06 --data-len=4096 --cdw10=1 -r
------------
+
* Or if you want to save that structure to a file:
+
------------
# nvme admin-passthru /dev/nvme0 --opcode=06 --data-len=4096 --cdw10=1 -r -b > id_ns.raw
------------
NVME
----
Part of the nvme-user suite
|