summaryrefslogtreecommitdiffstats
path: root/Documentation/nvme-dir-send.1
blob: 2655e9ffd8b8c178f7377a684f3091d15c15d8d3 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
'\" t
.\"     Title: nvme-dir-send
.\"    Author: [FIXME: author] [see http://www.docbook.org/tdg5/en/html/author]
.\" Generator: DocBook XSL Stylesheets vsnapshot <http://docbook.sf.net/>
.\"      Date: 05/03/2024
.\"    Manual: NVMe Manual
.\"    Source: NVMe
.\"  Language: English
.\"
.TH "NVME\-DIR\-SEND" "1" "05/03/2024" "NVMe" "NVMe Manual"
.\" -----------------------------------------------------------------
.\" * Define some portability stuff
.\" -----------------------------------------------------------------
.\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
.\" http://bugs.debian.org/507673
.\" http://lists.gnu.org/archive/html/groff/2009-02/msg00013.html
.\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
.ie \n(.g .ds Aq \(aq
.el       .ds Aq '
.\" -----------------------------------------------------------------
.\" * set default formatting
.\" -----------------------------------------------------------------
.\" disable hyphenation
.nh
.\" disable justification (adjust text to left margin only)
.ad l
.\" -----------------------------------------------------------------
.\" * MAIN CONTENT STARTS HERE *
.\" -----------------------------------------------------------------
.SH "NAME"
nvme-dir-send \- Issue a directive send command, returns applicable results
.SH "SYNOPSIS"
.sp
.nf
\fInvme dir\-send\fR <device> [\-\-namespace\-id=<nsid> | \-n <nsid>]
                        [\-\-data\-len=<data\-len> | \-l <data\-len>]
                        [\-\-dir\-type=<dtype> | \-D <dtype>]
                        [\-\-dir\-spec=<dspec> | \-S <dspec>]
                        [\-\-dir\-oper=<doper> | \-O <doper>]
                        [\-\-endir=<endir> | \-e <endir>]
                        [\-\-target\-dir=<tdir> | \-T <tdir>]
                        [\-\-human\-readable | \-H] [\-\-raw\-binary | \-b]
                        [\-\-output\-format=<fmt> | \-o <fmt>] [\-\-verbose | \-v]
.fi
.SH "DESCRIPTION"
.sp
Submits an NVMe Directive Send admin command and returns the applicable results\&. This may be the combination of directive type, and operation, as well as target directive and its enable/disable status of the operation, if specific operation needs it\&.
.sp
The <device> parameter is mandatory and may be either the NVMe character device (ex: /dev/nvme0), or a namespace block device (ex: /dev/nvme0n1)\&.
.sp
On success, the returned directive\(cqs parameter structure (if applicable) is returned in one of several ways depending on the option flags; the structure may parsed by the program and printed in a readable format if it is a known structure, displayed in hex, or the raw buffer may be printed to stdout for another program to parse\&.
.SH "OPTIONS"
.PP
\-n <nsid>, \-\-namespace\-id=<nsid>
.RS 4
Retrieve the feature for the given nsid\&. This is optional and most features do not use this value\&.
.RE
.PP
\-D <dtype>, \-\-dir\-type=<dtype>
.RS 4
Directive type
.RE
.PP
\-S <dspec>, \-\-dir\-spec=<dspec>
.RS 4
Directive specific
.RE
.PP
\-O <doper>, \-\-dir\-oper=<doper>
.RS 4
Directive operation
.RE
.PP
\-T <tdir>, \-\-target\-dir=<nsr>
.RS 4
Target directive of the operation
.RE
.PP
\-e <endir>, \-\-endir=<endir>
.RS 4
Target directive enable(1) or disable (0) operation
.TS
allbox tab(:);
lt lt
lt lt
lt lt
lt lt
lt lt
lt lt.
T{
Select
T}:T{
Description
T}
T{
0
T}:T{
Current
T}
T{
1
T}:T{
Default
T}
T{
2
T}:T{
Saved
T}
T{
3
T}:T{
Supported capabilities
T}
T{
4\(en7
T}:T{
Reserved
T}
.TE
.sp 1
.RE
.PP
\-l <data\-len>, \-\-data\-len=<data\-len>
.RS 4
The data length for the buffer returned for this feature\&. Most known features do not use this value\&. The exception is LBA Range Type
.RE
.PP
\-b, \-\-raw\-binary
.RS 4
Print the raw receive buffer to stdout if the command returns a structure\&.
.RE
.PP
\-H, \-\-human\-readable
.RS 4
Print the decoded receive buffer to stdout if the command returns a structure\&.
.RE
.PP
\-o <fmt>, \-\-output\-format=<fmt>
.RS 4
Set the reporting format to
\fInormal\fR,
\fIjson\fR
or
\fIbinary\fR\&. Only one output format can be used at a time\&.
.RE
.PP
\-v, \-\-verbose
.RS 4
Increase the information detail in the output\&.
.RE
.SH "EXAMPLES"
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
Enable streams directive :
.sp
.if n \{\
.RS 4
.\}
.nf
# nvme dir\-send /dev/nvme0n1 \-\-dir\-type 0 \-\-dir\-oper 1 \-\-target\-dir 1 \-\-endir 1
.fi
.if n \{\
.RE
.\}
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
Disable streams directive :
.sp
.if n \{\
.RS 4
.\}
.nf
# nvme dir\-send /dev/nvme0n1 \-\-dir\-type 0 \-\-dir\-oper 1 \-\-target\-dir 1 \-\-endir 0
.fi
.if n \{\
.RE
.\}
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
Release all allocated streams resource :
.sp
.if n \{\
.RS 4
.\}
.nf
# nvme dir\-send /dev/nvme0n1 \-\-dir\-type 1 \-\-dir\-oper 2
.fi
.if n \{\
.RE
.\}
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
Release stream ID 3 :
.sp
.if n \{\
.RS 4
.\}
.nf
# nvme dir\-send /dev/nvme0 \-\-dir\-type 1 \-\-dir\-oper 1 \-\-dir\-spec 3
.fi
.if n \{\
.RE
.\}
.sp
It is probably a bad idea to not redirect stdout when using this mode\&.
.RE
.SH "NVME"
.sp
Part of the nvme\-user suite