summaryrefslogtreecommitdiffstats
path: root/Documentation/nvme-write.txt
blob: 8dbad98c3b3bac743fddabfb9fa60f03ced9d2e1 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
nvme-write(1)
=============

NAME
----
nvme-write - Send an NVMe write command, provide results

SYNOPSIS
--------
[verse]
'nvme-write' <device> [--start-block=<slba> | -s <slba>]
			[--block-count=<nlb> | -c <nlb>]
			[--data-size=<size> | -z <size>]
			[--metadata-size=<size> | -y <size>]
			[--ref-tag=<reftag> | -r <reftag>]
			[--data=<data-file> | -d <data-file>]
			[--metadata=<metadata-file> | -M <metadata-file>]
			[--prinfo=<prinfo> | -p <prinfo>]
			[--app-tag-mask=<appmask> | -m <appmask>]
			[--app-tag=<apptag> | -a <apptag>]
			[--limited-retry | -l] [--force-unit-access | -f]
			[--dir-type=<type> | -T <type>]
			[--dir-spec=<spec> | -S <spec>] [--dsm=<dsm> | -D <dsm>]
			[--show-command | -V] [--dry-run | -w] [--latency | -t]
			[--storage-tag<storage-tag> | -g <storage-tag>]
			[--storage-tag-check | -C] [--force]
			[--output-format=<fmt> | -o <fmt>] [--verbose | -v]
			[--timeout=<timeout>]

DESCRIPTION
-----------
The Write command writes the logical blocks specified by the command to
the medium from the data data buffer provided. Will use stdin by default
if you don't provide a file.

OPTIONS
-------
-s <slba>::
--start-block=<slba>::
	Start block.

-c::
--block-count::
	The number of blocks to transfer. This is a zeroes based value to
	align with the kernel's use of this field. (ie. 0 means transfer
	1 block).

-z <size>::
--data-size=<size>::
	Size of data, in bytes.

-y <size>::
--metadata-size=<size>::
	Size of metadata in bytes.

-d <data-file>::
--data=<data-file>::
	Data file. If none provided, contents are sent from STDIN.

-M <metadata-file>::
--metadata=<metadata-file>::
	Metadata file, if necessary.

-p <prinfo>::
--prinfo=<prinfo>::
	Protection Information field definition.
+
[]
|=================
|Bit|Description
|3|PRACT: Protection Information Action. When set to 1, PI is stripped/inserted
on read/write when the block format's metadata size is 8. When set to 0,
metadata is passes.
|2:0|PRCHK: Protection Information Check:
|2|Set to 1 enables checking the guard tag
|1|Set to 1 enables checking the application tag
|0|Set to 1 enables checking the reference tag
|=================

-r <reftag>::
--ref-tag=<reftag>::
	Optional reftag when used with protection information.

-m <appmask>::
--app-tag-mask=<appmask>::
	Optional application tag mask when used with protection information.

-a <apptag>::
--app-tag=<apptag>::
	Optional application tag when used with protection information.

-l::
--limited-retry::
	Sets the limited retry flag.

-f::
--force-unit-access::
	Set the force-unit access flag.

-T <type>::
--dir-type=<type>::
	Optional directive type. The nvme-cli only enforces the value
	be in the defined range for the directive type, though the NVMe
	specification (1.3a) defines only one directive, 01h, for write
	stream identifiers.

-S <spec>::
--dir-spec=<spec>::
	Optional field for directive specifics. When used with
	write streams, this value is defined to be the write stream
	identifier. The nvme-cli will not validate the stream requested
	is within the controller's capabilities.

-D <dsm>::
--dsm=<dsm>::
	The optional data set management attributes for this command. The argument
	for this is the least significant 8 bits of the DSM field in a write
	command; the most significant 16 bits of the field come from the directive
	specific field, if used. This may be used to set attributes for
	the LBAs being written, like access frequency, type, latency,
	among other things, as well as yet to be defined types. Please
	consult the NVMe specification for detailed breakdown of how to
	use this field.

-V::
--show-cmd::
	Print out the command to be sent.

-w::
--dry-run::
	Do not actually send the command. If want to use --dry-run option,
	--show-cmd option _must_ be set. Otherwise --dry-run option will be
	_ignored_.

-t::
--latency::
	Print out the latency the IOCTL took (in us).

-g <storage-tag>::
--storage-tag=<storage-tag>::
	Variable Sized Expected Logical Block Storage Tag(ELBST).

-C::
--storage-tag-check::
	This flag enables Storage Tag field checking as part of end-to-end
	data protection processing.

--force::
	Ignore namespace is currently busy and performed the operation
	even though.

-o <fmt>::
--output-format=<fmt>::
	Set the reporting format to 'normal', 'json' or 'binary'. Only one
	output format can be used at a time.

-v::
--verbose::
	Increase the information detail in the output.

--timeout=<timeout>::
	Override default timeout value. In milliseconds.

EXAMPLES
--------
No examples yet.

NVME
----
Part of the nvme-user suite