summaryrefslogtreecommitdiffstats
path: root/tools/perf/pmu-events/arch/powerpc
diff options
context:
space:
mode:
authorDaniel Baumann <daniel.baumann@progress-linux.org>2024-05-08 04:17:45 +0000
committerDaniel Baumann <daniel.baumann@progress-linux.org>2024-05-08 04:17:45 +0000
commit41fb2ba1cd2e84f28cd9f5b91d670fef7d982409 (patch)
tree3518db389445fe1c1e74d64e3598ed34c6e2c59a /tools/perf/pmu-events/arch/powerpc
parentReleasing progress-linux version 4.19.282-1progress5u1. (diff)
downloadlinux-41fb2ba1cd2e84f28cd9f5b91d670fef7d982409.tar.xz
linux-41fb2ba1cd2e84f28cd9f5b91d670fef7d982409.zip
Merging upstream version 4.19.289.
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'tools/perf/pmu-events/arch/powerpc')
-rw-r--r--tools/perf/pmu-events/arch/powerpc/power9/other.json4
-rw-r--r--tools/perf/pmu-events/arch/powerpc/power9/pipeline.json2
2 files changed, 3 insertions, 3 deletions
diff --git a/tools/perf/pmu-events/arch/powerpc/power9/other.json b/tools/perf/pmu-events/arch/powerpc/power9/other.json
index 48cf4f920..064341c0d 100644
--- a/tools/perf/pmu-events/arch/powerpc/power9/other.json
+++ b/tools/perf/pmu-events/arch/powerpc/power9/other.json
@@ -1417,7 +1417,7 @@
{,
"EventCode": "0x45054",
"EventName": "PM_FMA_CMPL",
- "BriefDescription": "two flops operation completed (fmadd, fnmadd, fmsub, fnmsub) Scalar instructions only. "
+ "BriefDescription": "two flops operation completed (fmadd, fnmadd, fmsub, fnmsub) Scalar instructions only."
},
{,
"EventCode": "0x201E8",
@@ -2017,7 +2017,7 @@
{,
"EventCode": "0xC0BC",
"EventName": "PM_LSU_FLUSH_OTHER",
- "BriefDescription": "Other LSU flushes including: Sync (sync ack from L2 caused search of LRQ for oldest snooped load, This will either signal a Precise Flush of the oldest snooped loa or a Flush Next PPC); Data Valid Flush Next (several cases of this, one example is store and reload are lined up such that a store-hit-reload scenario exists and the CDF has already launched and has gotten bad/stale data); Bad Data Valid Flush Next (might be a few cases of this, one example is a larxa (D$ hit) return data and dval but can't allocate to LMQ (LMQ full or other reason). Already gave dval but can't watch it for snoop_hit_larx. Need to take the “bad dval” back and flush all younger ops)"
+ "BriefDescription": "Other LSU flushes including: Sync (sync ack from L2 caused search of LRQ for oldest snooped load, This will either signal a Precise Flush of the oldest snooped loa or a Flush Next PPC); Data Valid Flush Next (several cases of this, one example is store and reload are lined up such that a store-hit-reload scenario exists and the CDF has already launched and has gotten bad/stale data); Bad Data Valid Flush Next (might be a few cases of this, one example is a larxa (D$ hit) return data and dval but can't allocate to LMQ (LMQ full or other reason). Already gave dval but can't watch it for snoop_hit_larx. Need to take the 'bad dval' back and flush all younger ops)"
},
{,
"EventCode": "0x5094",
diff --git a/tools/perf/pmu-events/arch/powerpc/power9/pipeline.json b/tools/perf/pmu-events/arch/powerpc/power9/pipeline.json
index b4772f54a..e2f2ed0a3 100644
--- a/tools/perf/pmu-events/arch/powerpc/power9/pipeline.json
+++ b/tools/perf/pmu-events/arch/powerpc/power9/pipeline.json
@@ -442,7 +442,7 @@
{,
"EventCode": "0x4D052",
"EventName": "PM_2FLOP_CMPL",
- "BriefDescription": "DP vector version of fmul, fsub, fcmp, fsel, fabs, fnabs, fres ,fsqrte, fneg "
+ "BriefDescription": "DP vector version of fmul, fsub, fcmp, fsel, fabs, fnabs, fres ,fsqrte, fneg"
},
{,
"EventCode": "0x1F142",