summaryrefslogtreecommitdiffstats
path: root/Documentation/devicetree/bindings/regulator/qcom,spmi-regulator.txt
blob: 406f2e570c50de2650c30fbba09d809efe0cb888 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
Qualcomm SPMI Regulators

- compatible:
	Usage: required
	Value type: <string>
	Definition: must be one of:
			"qcom,pm8841-regulators"
			"qcom,pm8916-regulators"
			"qcom,pm8941-regulators"
			"qcom,pm8994-regulators"
			"qcom,pmi8994-regulators"

- interrupts:
	Usage: optional
	Value type: <prop-encoded-array>
	Definition: List of OCP interrupts.

- interrupt-names:
	Usage: required if 'interrupts' property present
	Value type: <string-array>
	Definition: List of strings defining the names of the
		    interrupts in the 'interrupts' property 1-to-1.
		    Supported values are "ocp-<regulator_name>", where
		    <regulator_name> corresponds to a voltage switch
		    type regulator.

- vdd_s1-supply:
- vdd_s2-supply:
- vdd_s3-supply:
- vdd_s4-supply:
- vdd_s5-supply:
- vdd_s6-supply:
- vdd_s7-supply:
- vdd_s8-supply:
	Usage: optional (pm8841 only)
	Value type: <phandle>
	Definition: Reference to regulator supplying the input pin, as
		    described in the data sheet.

- vdd_s1-supply:
- vdd_s2-supply:
- vdd_s3-supply:
- vdd_s4-supply:
- vdd_l1_l3-supply:
- vdd_l2-supply:
- vdd_l4_l5_l6-supply:
- vdd_l7-supply:
- vdd_l8_l11_l14_l15_l16-supply:
- vdd_l9_l10_l12_l13_l17_l18-supply:
	Usage: optional (pm8916 only)
	Value type: <phandle>
	Definition: Reference to regulator supplying the input pin, as
		    described in the data sheet.

- vdd_s1-supply:
- vdd_s2-supply:
- vdd_s3-supply:
- vdd_l1_l3-supply:
- vdd_l2_lvs_1_2_3-supply:
- vdd_l4_l11-supply:
- vdd_l5_l7-supply:
- vdd_l6_l12_l14_l15-supply:
- vdd_l8_l16_l18_19-supply:
- vdd_l9_l10_l17_l22-supply:
- vdd_l13_l20_l23_l24-supply:
- vdd_l21-supply:
- vin_5vs-supply:
	Usage: optional (pm8941 only)
	Value type: <phandle>
	Definition: Reference to regulator supplying the input pin, as
		    described in the data sheet.

- vdd_s1-supply:
- vdd_s2-supply:
- vdd_s3-supply:
- vdd_s4-supply:
- vdd_s5-supply:
- vdd_s6-supply:
- vdd_s7-supply:
- vdd_s8-supply:
- vdd_s9-supply:
- vdd_s10-supply:
- vdd_s11-supply:
- vdd_s12-supply:
- vdd_l1-supply:
- vdd_l2_l26_l28-supply:
- vdd_l3_l11-supply:
- vdd_l4_l27_l31-supply:
- vdd_l5_l7-supply:
- vdd_l6_l12_l32-supply:
- vdd_l8_l16_l30-supply:
- vdd_l9_l10_l18_l22-supply:
- vdd_l13_l19_l23_l24-supply:
- vdd_l14_l15-supply:
- vdd_l17_l29-supply:
- vdd_l20_l21-supply:
- vdd_l25-supply:
- vdd_lvs_1_2-supply:
	Usage: optional (pm8994 only)
	Value type: <phandle>
	Definition: Reference to regulator supplying the input pin, as
		    described in the data sheet.

- vdd_s1-supply:
- vdd_s2-supply:
- vdd_s3-supply:
- vdd_l1-supply:
	Usage: optional (pmi8994 only)
	Value type: <phandle>
	Definition: Reference to regulator supplying the input pin, as
		    described in the data sheet.

- qcom,saw-reg:
	Usage: optional
	Value type: <phandle>
	Description: Reference to syscon node defining the SAW registers.


The regulator node houses sub-nodes for each regulator within the device. Each
sub-node is identified using the node's name, with valid values listed for each
of the PMICs below.

pm8841:
	s1, s2, s3, s4, s5, s6, s7, s8

pm8916:
	s1, s2, s3, s4, l1, l2, l3, l4, l5, l6, l7, l8, l9, l10, l11, l12, l13,
	l14, l15, l16, l17, l18

pm8941:
	s1, s2, s3, s4, l1, l2, l3, l4, l5, l6, l7, l8, l9, l10, l11, l12, l13,
	l14, l15, l16, l17, l18, l19, l20, l21, l22, l23, l24, lvs1, lvs2, lvs3,
	5vs1, 5vs2

pm8994:
	s1, s2, s3, s4, s5, s6, s7, s8, s9, s10, s11, s12, l1, l2, l3, l4, l5,
	l6, l7, l8, l9, l10, l11, l12, l13, l14, l15, l16, l17, l18, l19, l20,
	l21, l22, l23, l24, l25, l26, l27, l28, l29, l30, l31, l32, lvs1, lvs2

pmi8994:
	s1, s2, s3, l1

The content of each sub-node is defined by the standard binding for regulators -
see regulator.txt - with additional custom properties described below:

- regulator-initial-mode:
	Usage: optional
	Value type: <u32>
	Description: 2 = Set initial mode to auto mode (automatically select
		    between HPM and LPM); not available on boost type
		    regulators.

		    1 = Set initial mode to high power mode (HPM), also referred
		    to as NPM. HPM consumes more ground current than LPM, but
		    it can source significantly higher load current. HPM is not
		    available on boost type regulators. For voltage switch type
		    regulators, HPM implies that over current protection and
		    soft start are active all the time.

		    0 = Set initial mode to low power mode (LPM).

- qcom,ocp-max-retries:
	Usage: optional
	Value type: <u32>
	Description: Maximum number of times to try toggling a voltage switch
		     off and back on as a result of consecutive over current
		     events.

- qcom,ocp-retry-delay:
	Usage: optional
	Value type: <u32>
	Description: Time to delay in milliseconds between each voltage switch
		     toggle after an over current event takes place.

- qcom,pin-ctrl-enable:
	Usage: optional
	Value type: <u32>
	Description: Bit mask specifying which hardware pins should be used to
		     enable the regulator, if any; supported bits are:
			0 = ignore all hardware enable signals
			BIT(0) = follow HW0_EN signal
			BIT(1) = follow HW1_EN signal
			BIT(2) = follow HW2_EN signal
			BIT(3) = follow HW3_EN signal

- qcom,pin-ctrl-hpm:
	Usage: optional
	Value type: <u32>
	Description: Bit mask specifying which hardware pins should be used to
		     force the regulator into high power mode, if any;
		     supported bits are:
			0 = ignore all hardware enable signals
			BIT(0) = follow HW0_EN signal
			BIT(1) = follow HW1_EN signal
			BIT(2) = follow HW2_EN signal
			BIT(3) = follow HW3_EN signal
			BIT(4) = follow PMIC awake state

- qcom,vs-soft-start-strength:
	Usage: optional
	Value type: <u32>
	Description: This property sets the soft start strength for voltage
		     switch type regulators; supported values are:
			0 = 0.05 uA
			1 = 0.25 uA
			2 = 0.55 uA
			3 = 0.75 uA

- qcom,saw-slave:
	Usage: optional
	Value type: <boo>
	Description: SAW controlled gang slave. Will not be configured.

- qcom,saw-leader:
	Usage: optional
	Value type: <boo>
	Description: SAW controlled gang leader. Will be configured as
		     SAW regulator.

Example:

	regulators {
		compatible = "qcom,pm8941-regulators";
		vdd_l1_l3-supply = <&s1>;

		s1: s1 {
			regulator-min-microvolt = <1300000>;
			regulator-max-microvolt = <1400000>;
		};

		...

		l1: l1 {
			regulator-min-microvolt = <1225000>;
			regulator-max-microvolt = <1300000>;
		};

		....
	};

Example 2:

	saw3: syscon@9A10000 {
		compatible = "syscon";
		reg = <0x9A10000 0x1000>;
	};

	...

	spm-regulators {
		compatible = "qcom,pm8994-regulators";
		qcom,saw-reg = <&saw3>;
		s8 {
			qcom,saw-slave;
		};
		s9 {
			qcom,saw-slave;
		};
		s10 {
			qcom,saw-slave;
		};
		pm8994_s11_saw: s11 {
			qcom,saw-leader;
			regulator-always-on;
			regulator-min-microvolt = <900000>;
			regulator-max-microvolt = <1140000>;
		};
	};