summaryrefslogtreecommitdiffstats
path: root/Documentation/ABI/testing/sysfs-class-power
diff options
context:
space:
mode:
authorDaniel Baumann <daniel.baumann@progress-linux.org>2024-05-06 01:02:30 +0000
committerDaniel Baumann <daniel.baumann@progress-linux.org>2024-05-06 01:02:30 +0000
commit76cb841cb886eef6b3bee341a2266c76578724ad (patch)
treef5892e5ba6cc11949952a6ce4ecbe6d516d6ce58 /Documentation/ABI/testing/sysfs-class-power
parentInitial commit. (diff)
downloadlinux-76cb841cb886eef6b3bee341a2266c76578724ad.tar.xz
linux-76cb841cb886eef6b3bee341a2266c76578724ad.zip
Adding upstream version 4.19.249.upstream/4.19.249upstream
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'Documentation/ABI/testing/sysfs-class-power')
-rw-r--r--Documentation/ABI/testing/sysfs-class-power589
1 files changed, 589 insertions, 0 deletions
diff --git a/Documentation/ABI/testing/sysfs-class-power b/Documentation/ABI/testing/sysfs-class-power
new file mode 100644
index 000000000..5e23e22dc
--- /dev/null
+++ b/Documentation/ABI/testing/sysfs-class-power
@@ -0,0 +1,589 @@
+===== General Properties =====
+
+What: /sys/class/power_supply/<supply_name>/manufacturer
+Date: May 2007
+Contact: linux-pm@vger.kernel.org
+Description:
+ Reports the name of the device manufacturer.
+
+ Access: Read
+ Valid values: Represented as string
+
+What: /sys/class/power_supply/<supply_name>/model_name
+Date: May 2007
+Contact: linux-pm@vger.kernel.org
+Description:
+ Reports the name of the device model.
+
+ Access: Read
+ Valid values: Represented as string
+
+What: /sys/class/power_supply/<supply_name>/serial_number
+Date: January 2008
+Contact: linux-pm@vger.kernel.org
+Description:
+ Reports the serial number of the device.
+
+ Access: Read
+ Valid values: Represented as string
+
+What: /sys/class/power_supply/<supply_name>/type
+Date: May 2010
+Contact: linux-pm@vger.kernel.org
+Description:
+ Describes the main type of the supply.
+
+ Access: Read
+ Valid values: "Battery", "UPS", "Mains", "USB"
+
+===== Battery Properties =====
+
+What: /sys/class/power_supply/<supply_name>/capacity
+Date: May 2007
+Contact: linux-pm@vger.kernel.org
+Description:
+ Fine grain representation of battery capacity.
+ Access: Read
+ Valid values: 0 - 100 (percent)
+
+What: /sys/class/power_supply/<supply_name>/capacity_alert_max
+Date: July 2012
+Contact: linux-pm@vger.kernel.org
+Description:
+ Maximum battery capacity trip-wire value where the supply will
+ notify user-space of the event. This is normally used for the
+ battery discharging scenario where user-space needs to know the
+ battery has dropped to an upper level so it can take
+ appropriate action (e.g. warning user that battery level is
+ low).
+
+ Access: Read, Write
+ Valid values: 0 - 100 (percent)
+
+What: /sys/class/power_supply/<supply_name>/capacity_alert_min
+Date: July 2012
+Contact: linux-pm@vger.kernel.org
+Description:
+ Minimum battery capacity trip-wire value where the supply will
+ notify user-space of the event. This is normally used for the
+ battery discharging scenario where user-space needs to know the
+ battery has dropped to a lower level so it can take
+ appropriate action (e.g. warning user that battery level is
+ critically low).
+
+ Access: Read, Write
+ Valid values: 0 - 100 (percent)
+
+What: /sys/class/power_supply/<supply_name>/capacity_level
+Date: June 2009
+Contact: linux-pm@vger.kernel.org
+Description:
+ Coarse representation of battery capacity.
+
+ Access: Read
+ Valid values: "Unknown", "Critical", "Low", "Normal", "High",
+ "Full"
+
+What: /sys/class/power_supply/<supply_name>/current_avg
+Date: May 2007
+Contact: linux-pm@vger.kernel.org
+Description:
+ Reports an average IBAT current reading for the battery, over a
+ fixed period. Normally devices will provide a fixed interval in
+ which they average readings to smooth out the reported value.
+
+ Access: Read
+ Valid values: Represented in microamps
+
+What: /sys/class/power_supply/<supply_name>/current_max
+Date: October 2010
+Contact: linux-pm@vger.kernel.org
+Description:
+ Reports the maximum IBAT current allowed into the battery.
+
+ Access: Read
+ Valid values: Represented in microamps
+
+What: /sys/class/power_supply/<supply_name>/current_now
+Date: May 2007
+Contact: linux-pm@vger.kernel.org
+Description:
+ Reports an instant, single IBAT current reading for the battery.
+ This value is not averaged/smoothed.
+
+ Access: Read
+ Valid values: Represented in microamps
+
+What: /sys/class/power_supply/<supply_name>/charge_type
+Date: July 2009
+Contact: linux-pm@vger.kernel.org
+Description:
+ Represents the type of charging currently being applied to the
+ battery.
+
+ Access: Read
+ Valid values: "Unknown", "N/A", "Trickle", "Fast"
+
+What: /sys/class/power_supply/<supply_name>/charge_term_current
+Date: July 2014
+Contact: linux-pm@vger.kernel.org
+Description:
+ Reports the charging current value which is used to determine
+ when the battery is considered full and charging should end.
+
+ Access: Read
+ Valid values: Represented in microamps
+
+What: /sys/class/power_supply/<supply_name>/health
+Date: May 2007
+Contact: linux-pm@vger.kernel.org
+Description:
+ Reports the health of the battery or battery side of charger
+ functionality.
+
+ Access: Read
+ Valid values: "Unknown", "Good", "Overheat", "Dead",
+ "Over voltage", "Unspecified failure", "Cold",
+ "Watchdog timer expire", "Safety timer expire"
+
+What: /sys/class/power_supply/<supply_name>/precharge_current
+Date: June 2017
+Contact: linux-pm@vger.kernel.org
+Description:
+ Reports the charging current applied during pre-charging phase
+ for a battery charge cycle.
+
+ Access: Read
+ Valid values: Represented in microamps
+
+What: /sys/class/power_supply/<supply_name>/present
+Date: May 2007
+Contact: linux-pm@vger.kernel.org
+Description:
+ Reports whether a battery is present or not in the system.
+
+ Access: Read
+ Valid values:
+ 0: Absent
+ 1: Present
+
+What: /sys/class/power_supply/<supply_name>/status
+Date: May 2007
+Contact: linux-pm@vger.kernel.org
+Description:
+ Represents the charging status of the battery. Normally this
+ is read-only reporting although for some supplies this can be
+ used to enable/disable charging to the battery.
+
+ Access: Read, Write
+ Valid values: "Unknown", "Charging", "Discharging",
+ "Not charging", "Full"
+
+What: /sys/class/power_supply/<supply_name>/technology
+Date: May 2007
+Contact: linux-pm@vger.kernel.org
+Description:
+ Describes the battery technology supported by the supply.
+
+ Access: Read
+ Valid values: "Unknown", "NiMH", "Li-ion", "Li-poly", "LiFe",
+ "NiCd", "LiMn"
+
+What: /sys/class/power_supply/<supply_name>/temp
+Date: May 2007
+Contact: linux-pm@vger.kernel.org
+Description:
+ Reports the current TBAT battery temperature reading.
+
+ Access: Read
+ Valid values: Represented in 1/10 Degrees Celsius
+
+What: /sys/class/power_supply/<supply_name>/temp_alert_max
+Date: July 2012
+Contact: linux-pm@vger.kernel.org
+Description:
+ Maximum TBAT temperature trip-wire value where the supply will
+ notify user-space of the event. This is normally used for the
+ battery charging scenario where user-space needs to know the
+ battery temperature has crossed an upper threshold so it can
+ take appropriate action (e.g. warning user that battery level is
+ critically high, and charging has stopped).
+
+ Access: Read
+ Valid values: Represented in 1/10 Degrees Celsius
+
+What: /sys/class/power_supply/<supply_name>/temp_alert_min
+Date: July 2012
+Contact: linux-pm@vger.kernel.org
+Description:
+ Minimum TBAT temperature trip-wire value where the supply will
+ notify user-space of the event. This is normally used for the
+ battery charging scenario where user-space needs to know the
+ battery temperature has crossed a lower threshold so it can take
+ appropriate action (e.g. warning user that battery level is
+ high, and charging current has been reduced accordingly to
+ remedy the situation).
+
+ Access: Read
+ Valid values: Represented in 1/10 Degrees Celsius
+
+What: /sys/class/power_supply/<supply_name>/temp_max
+Date: July 2014
+Contact: linux-pm@vger.kernel.org
+Description:
+ Reports the maximum allowed TBAT battery temperature for
+ charging.
+
+ Access: Read
+ Valid values: Represented in 1/10 Degrees Celsius
+
+What: /sys/class/power_supply/<supply_name>/temp_min
+Date: July 2014
+Contact: linux-pm@vger.kernel.org
+Description:
+ Reports the minimum allowed TBAT battery temperature for
+ charging.
+
+ Access: Read
+ Valid values: Represented in 1/10 Degrees Celsius
+
+What: /sys/class/power_supply/<supply_name>/voltage_avg,
+Date: May 2007
+Contact: linux-pm@vger.kernel.org
+Description:
+ Reports an average VBAT voltage reading for the battery, over a
+ fixed period. Normally devices will provide a fixed interval in
+ which they average readings to smooth out the reported value.
+
+ Access: Read
+ Valid values: Represented in microvolts
+
+What: /sys/class/power_supply/<supply_name>/voltage_max,
+Date: January 2008
+Contact: linux-pm@vger.kernel.org
+Description:
+ Reports the maximum safe VBAT voltage permitted for the battery,
+ during charging.
+
+ Access: Read
+ Valid values: Represented in microvolts
+
+What: /sys/class/power_supply/<supply_name>/voltage_min,
+Date: January 2008
+Contact: linux-pm@vger.kernel.org
+Description:
+ Reports the minimum safe VBAT voltage permitted for the battery,
+ during discharging.
+
+ Access: Read
+ Valid values: Represented in microvolts
+
+What: /sys/class/power_supply/<supply_name>/voltage_now,
+Date: May 2007
+Contact: linux-pm@vger.kernel.org
+Description:
+ Reports an instant, single VBAT voltage reading for the battery.
+ This value is not averaged/smoothed.
+
+ Access: Read
+ Valid values: Represented in microvolts
+
+===== USB Properties =====
+
+What: /sys/class/power_supply/<supply_name>/current_avg
+Date: May 2007
+Contact: linux-pm@vger.kernel.org
+Description:
+ Reports an average IBUS current reading over a fixed period.
+ Normally devices will provide a fixed interval in which they
+ average readings to smooth out the reported value.
+
+ Access: Read
+ Valid values: Represented in microamps
+
+
+What: /sys/class/power_supply/<supply_name>/current_max
+Date: October 2010
+Contact: linux-pm@vger.kernel.org
+Description:
+ Reports the maximum IBUS current the supply can support.
+
+ Access: Read
+ Valid values: Represented in microamps
+
+What: /sys/class/power_supply/<supply_name>/current_now
+Date: May 2007
+Contact: linux-pm@vger.kernel.org
+Description:
+ Reports the IBUS current supplied now. This value is generally
+ read-only reporting, unless the 'online' state of the supply
+ is set to be programmable, in which case this value can be set
+ within the reported min/max range.
+
+ Access: Read, Write
+ Valid values: Represented in microamps
+
+What: /sys/class/power_supply/<supply_name>/input_current_limit
+Date: July 2014
+Contact: linux-pm@vger.kernel.org
+Description:
+ Details the incoming IBUS current limit currently set in the
+ supply. Normally this is configured based on the type of
+ connection made (e.g. A configured SDP should output a maximum
+ of 500mA so the input current limit is set to the same value).
+
+ Access: Read, Write
+ Valid values: Represented in microamps
+
+What: /sys/class/power_supply/<supply_name>/online,
+Date: May 2007
+Contact: linux-pm@vger.kernel.org
+Description:
+ Indicates if VBUS is present for the supply. When the supply is
+ online, and the supply allows it, then it's possible to switch
+ between online states (e.g. Fixed -> Programmable for a PD_PPS
+ USB supply so voltage and current can be controlled).
+
+ Access: Read, Write
+ Valid values:
+ 0: Offline
+ 1: Online Fixed - Fixed Voltage Supply
+ 2: Online Programmable - Programmable Voltage Supply
+
+What: /sys/class/power_supply/<supply_name>/temp
+Date: May 2007
+Contact: linux-pm@vger.kernel.org
+Description:
+ Reports the current supply temperature reading. This would
+ normally be the internal temperature of the device itself (e.g
+ TJUNC temperature of an IC)
+
+ Access: Read
+ Valid values: Represented in 1/10 Degrees Celsius
+
+What: /sys/class/power_supply/<supply_name>/temp_alert_max
+Date: July 2012
+Contact: linux-pm@vger.kernel.org
+Description:
+ Maximum supply temperature trip-wire value where the supply will
+ notify user-space of the event. This is normally used for the
+ charging scenario where user-space needs to know the supply
+ temperature has crossed an upper threshold so it can take
+ appropriate action (e.g. warning user that the supply
+ temperature is critically high, and charging has stopped to
+ remedy the situation).
+
+ Access: Read
+ Valid values: Represented in 1/10 Degrees Celsius
+
+What: /sys/class/power_supply/<supply_name>/temp_alert_min
+Date: July 2012
+Contact: linux-pm@vger.kernel.org
+Description:
+ Minimum supply temperature trip-wire value where the supply will
+ notify user-space of the event. This is normally used for the
+ charging scenario where user-space needs to know the supply
+ temperature has crossed a lower threshold so it can take
+ appropriate action (e.g. warning user that the supply
+ temperature is high, and charging current has been reduced
+ accordingly to remedy the situation).
+
+ Access: Read
+ Valid values: Represented in 1/10 Degrees Celsius
+
+What: /sys/class/power_supply/<supply_name>/temp_max
+Date: July 2014
+Contact: linux-pm@vger.kernel.org
+Description:
+ Reports the maximum allowed supply temperature for operation.
+
+ Access: Read
+ Valid values: Represented in 1/10 Degrees Celsius
+
+What: /sys/class/power_supply/<supply_name>/temp_min
+Date: July 2014
+Contact: linux-pm@vger.kernel.org
+Description:
+ Reports the mainimum allowed supply temperature for operation.
+
+ Access: Read
+ Valid values: Represented in 1/10 Degrees Celsius
+
+What: /sys/class/power_supply/<supply_name>/usb_type
+Date: March 2018
+Contact: linux-pm@vger.kernel.org
+Description:
+ Reports what type of USB connection is currently active for
+ the supply, for example it can show if USB-PD capable source
+ is attached.
+
+ Access: Read-Only
+ Valid values: "Unknown", "SDP", "DCP", "CDP", "ACA", "C", "PD",
+ "PD_DRP", "PD_PPS", "BrickID"
+
+What: /sys/class/power_supply/<supply_name>/voltage_max
+Date: January 2008
+Contact: linux-pm@vger.kernel.org
+Description:
+ Reports the maximum VBUS voltage the supply can support.
+
+ Access: Read
+ Valid values: Represented in microvolts
+
+What: /sys/class/power_supply/<supply_name>/voltage_min
+Date: January 2008
+Contact: linux-pm@vger.kernel.org
+Description:
+ Reports the minimum VBUS voltage the supply can support.
+
+ Access: Read
+ Valid values: Represented in microvolts
+
+What: /sys/class/power_supply/<supply_name>/voltage_now
+Date: May 2007
+Contact: linux-pm@vger.kernel.org
+Description:
+ Reports the VBUS voltage supplied now. This value is generally
+ read-only reporting, unless the 'online' state of the supply
+ is set to be programmable, in which case this value can be set
+ within the reported min/max range.
+
+ Access: Read, Write
+ Valid values: Represented in microvolts
+
+===== Device Specific Properties =====
+
+What: /sys/class/power/ds2760-battery.*/charge_now
+Date: May 2010
+KernelVersion: 2.6.35
+Contact: Daniel Mack <daniel@caiaq.de>
+Description:
+ This file is writeable and can be used to set the current
+ coloumb counter value inside the battery monitor chip. This
+ is needed for unavoidable corrections of aging batteries.
+ A userspace daemon can monitor the battery charging logic
+ and once the counter drops out of considerable bounds, take
+ appropriate action.
+
+What: /sys/class/power/ds2760-battery.*/charge_full
+Date: May 2010
+KernelVersion: 2.6.35
+Contact: Daniel Mack <daniel@caiaq.de>
+Description:
+ This file is writeable and can be used to set the assumed
+ battery 'full level'. As batteries age, this value has to be
+ amended over time.
+
+What: /sys/class/power_supply/max14577-charger/device/fast_charge_timer
+Date: October 2014
+KernelVersion: 3.18.0
+Contact: Krzysztof Kozlowski <krzk@kernel.org>
+Description:
+ This entry shows and sets the maximum time the max14577
+ charger operates in fast-charge mode. When the timer expires
+ the device will terminate fast-charge mode (charging current
+ will drop to 0 A) and will trigger interrupt.
+
+ Valid values:
+ - 5, 6 or 7 (hours),
+ - 0: disabled.
+
+What: /sys/class/power_supply/max77693-charger/device/fast_charge_timer
+Date: January 2015
+KernelVersion: 3.19.0
+Contact: Krzysztof Kozlowski <krzk@kernel.org>
+Description:
+ This entry shows and sets the maximum time the max77693
+ charger operates in fast-charge mode. When the timer expires
+ the device will terminate fast-charge mode (charging current
+ will drop to 0 A) and will trigger interrupt.
+
+ Valid values:
+ - 4 - 16 (hours), step by 2 (rounded down)
+ - 0: disabled.
+
+What: /sys/class/power_supply/max77693-charger/device/top_off_threshold_current
+Date: January 2015
+KernelVersion: 3.19.0
+Contact: Krzysztof Kozlowski <krzk@kernel.org>
+Description:
+ This entry shows and sets the charging current threshold for
+ entering top-off charging mode. When charging current in fast
+ charge mode drops below this value, the charger will trigger
+ interrupt and start top-off charging mode.
+
+ Valid values:
+ - 100000 - 200000 (microamps), step by 25000 (rounded down)
+ - 200000 - 350000 (microamps), step by 50000 (rounded down)
+ - 0: disabled.
+
+What: /sys/class/power_supply/max77693-charger/device/top_off_timer
+Date: January 2015
+KernelVersion: 3.19.0
+Contact: Krzysztof Kozlowski <krzk@kernel.org>
+Description:
+ This entry shows and sets the maximum time the max77693
+ charger operates in top-off charge mode. When the timer expires
+ the device will terminate top-off charge mode (charging current
+ will drop to 0 A) and will trigger interrupt.
+
+ Valid values:
+ - 0 - 70 (minutes), step by 10 (rounded down)
+
+What: /sys/class/power_supply/bq24257-charger/ovp_voltage
+Date: October 2015
+KernelVersion: 4.4.0
+Contact: Andreas Dannenberg <dannenberg@ti.com>
+Description:
+ This entry configures the overvoltage protection feature of bq24257-
+ type charger devices. This feature protects the device and other
+ components against damage from overvoltage on the input supply. See
+ device datasheet for details.
+
+ Valid values:
+ - 6000000, 6500000, 7000000, 8000000, 9000000, 9500000, 10000000,
+ 10500000 (all uV)
+
+What: /sys/class/power_supply/bq24257-charger/in_dpm_voltage
+Date: October 2015
+KernelVersion: 4.4.0
+Contact: Andreas Dannenberg <dannenberg@ti.com>
+Description:
+ This entry configures the input dynamic power path management voltage of
+ bq24257-type charger devices. Once the supply drops to the configured
+ voltage, the input current limit is reduced down to prevent the further
+ drop of the supply. When the IC enters this mode, the charge current is
+ lower than the set value. See device datasheet for details.
+
+ Valid values:
+ - 4200000, 4280000, 4360000, 4440000, 4520000, 4600000, 4680000,
+ 4760000 (all uV)
+
+What: /sys/class/power_supply/bq24257-charger/high_impedance_enable
+Date: October 2015
+KernelVersion: 4.4.0
+Contact: Andreas Dannenberg <dannenberg@ti.com>
+Description:
+ This entry allows enabling the high-impedance mode of bq24257-type
+ charger devices. If enabled, it places the charger IC into low power
+ standby mode with the switch mode controller disabled. When disabled,
+ the charger operates normally. See device datasheet for details.
+
+ Valid values:
+ - 1: enabled
+ - 0: disabled
+
+What: /sys/class/power_supply/bq24257-charger/sysoff_enable
+Date: October 2015
+KernelVersion: 4.4.0
+Contact: Andreas Dannenberg <dannenberg@ti.com>
+Description:
+ This entry allows enabling the sysoff mode of bq24257-type charger
+ devices. If enabled and the input is removed, the internal battery FET
+ is turned off in order to reduce the leakage from the BAT pin to less
+ than 1uA. Note that on some devices/systems this disconnects the battery
+ from the system. See device datasheet for details.
+
+ Valid values:
+ - 1: enabled
+ - 0: disabled