summaryrefslogtreecommitdiffstats
path: root/Documentation/devicetree/bindings/power/supply/act8945a-charger.txt
diff options
context:
space:
mode:
authorDaniel Baumann <daniel.baumann@progress-linux.org>2024-05-06 01:02:30 +0000
committerDaniel Baumann <daniel.baumann@progress-linux.org>2024-05-06 01:02:30 +0000
commit76cb841cb886eef6b3bee341a2266c76578724ad (patch)
treef5892e5ba6cc11949952a6ce4ecbe6d516d6ce58 /Documentation/devicetree/bindings/power/supply/act8945a-charger.txt
parentInitial commit. (diff)
downloadlinux-upstream.tar.xz
linux-upstream.zip
Adding upstream version 4.19.249.upstream/4.19.249upstream
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'Documentation/devicetree/bindings/power/supply/act8945a-charger.txt')
-rw-r--r--Documentation/devicetree/bindings/power/supply/act8945a-charger.txt44
1 files changed, 44 insertions, 0 deletions
diff --git a/Documentation/devicetree/bindings/power/supply/act8945a-charger.txt b/Documentation/devicetree/bindings/power/supply/act8945a-charger.txt
new file mode 100644
index 000000000..c7dfb7cec
--- /dev/null
+++ b/Documentation/devicetree/bindings/power/supply/act8945a-charger.txt
@@ -0,0 +1,44 @@
+Device-Tree bindings for charger of Active-semi ACT8945A Multi-Function Device
+
+Required properties:
+ - compatible: "active-semi,act8945a-charger".
+ - active-semi,chglev-gpios: charge current level phandle with args
+ as described in ../gpio/gpio.txt.
+ - active-semi,lbo-gpios: specify the low battery voltage detect phandle
+ with args as as described in ../gpio/gpio.txt.
+ - interrupts: <a b> where a is the interrupt number and b is a
+ field that represents an encoding of the sense and level
+ information for the interrupt.
+
+Optional properties:
+ - active-semi,input-voltage-threshold-microvolt: unit: mV;
+ Specifies the charger's input over-voltage threshold value;
+ The value can be: 6600, 7000, 7500, 8000; default: 6600
+ - active-semi,precondition-timeout: unit: minutes;
+ Specifies the charger's PRECONDITION safety timer setting value;
+ The value can be: 40, 60, 80, 0; If 0, it means to disable this timer;
+ default: 40.
+ - active-semi,total-timeout: unit: hours;
+ Specifies the charger's total safety timer setting value;
+ The value can be: 3, 4, 5, 0; If 0, it means to disable this timer;
+ default: 3.
+
+Example:
+ pmic@5b {
+ compatible = "active-semi,act8945a";
+ reg = <0x5b>;
+
+ charger {
+ compatible = "active-semi,act8945a-charger";
+ pinctrl-names = "default";
+ pinctrl-0 = <&pinctrl_charger_chglev &pinctrl_charger_lbo &pinctrl_charger_irq>;
+ interrupt-parent = <&pioA>;
+ interrupts = <45 GPIO_ACTIVE_LOW>;
+
+ active-semi,chglev-gpios = <&pioA 12 GPIO_ACTIVE_HIGH>;
+ active-semi,lbo-gpios = <&pioA 72 GPIO_ACTIVE_LOW>;
+ active-semi,input-voltage-threshold-microvolt = <6600>;
+ active-semi,precondition-timeout = <40>;
+ active-semi,total-timeout = <3>;
+ };
+ };