summaryrefslogtreecommitdiffstats
path: root/Documentation/devicetree/bindings/power/renesas,sysc-rmobile.txt
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation/devicetree/bindings/power/renesas,sysc-rmobile.txt')
-rw-r--r--Documentation/devicetree/bindings/power/renesas,sysc-rmobile.txt100
1 files changed, 100 insertions, 0 deletions
diff --git a/Documentation/devicetree/bindings/power/renesas,sysc-rmobile.txt b/Documentation/devicetree/bindings/power/renesas,sysc-rmobile.txt
new file mode 100644
index 000000000..beda7d2ef
--- /dev/null
+++ b/Documentation/devicetree/bindings/power/renesas,sysc-rmobile.txt
@@ -0,0 +1,100 @@
+DT bindings for the Renesas R-Mobile System Controller
+
+== System Controller Node ==
+
+The R-Mobile System Controller provides the following functions:
+ - Boot mode management,
+ - Reset generation,
+ - Power management.
+
+Required properties:
+- compatible: Should be "renesas,sysc-<soctype>", "renesas,sysc-rmobile" as
+ fallback.
+ Examples with soctypes are:
+ - "renesas,sysc-r8a73a4" (R-Mobile APE6)
+ - "renesas,sysc-r8a7740" (R-Mobile A1)
+ - "renesas,sysc-sh73a0" (SH-Mobile AG5)
+- reg: Two address start and address range blocks for the device:
+ - The first block refers to the normally accessible registers,
+ - the second block refers to the registers protected by the HPB
+ semaphore.
+
+Optional nodes:
+- pm-domains: This node contains a hierarchy of PM domain nodes, which should
+ match the Power Area Hierarchy in the Power Domain Specifications section of
+ the device's datasheet.
+
+
+== PM Domain Nodes ==
+
+Each of the PM domain nodes represents a PM domain, as documented by the
+generic PM domain bindings in
+Documentation/devicetree/bindings/power/power_domain.txt.
+
+The nodes should be named by the real power area names, and thus their names
+should be unique.
+
+Required properties:
+ - #power-domain-cells: Must be 0.
+
+Optional properties:
+- reg: If the PM domain is not always-on, this property must contain the bit
+ index number for the corresponding power area in the various Power
+ Control and Status Registers. The parent's node must contain the
+ following two properties:
+ - #address-cells: Must be 1,
+ - #size-cells: Must be 0.
+ If the PM domain is always-on, this property must be omitted.
+
+
+Example:
+
+This shows a subset of the r8a7740 PM domain hierarchy, containing the
+C5 "always-on" domain, 2 of its subdomains (A4S and A4SU), and the A3SP domain,
+which is a subdomain of A4S.
+
+ sysc: system-controller@e6180000 {
+ compatible = "renesas,sysc-r8a7740", "renesas,sysc-rmobile";
+ reg = <0xe6180000 0x8000>, <0xe6188000 0x8000>;
+
+ pm-domains {
+ pd_c5: c5 {
+ #address-cells = <1>;
+ #size-cells = <0>;
+ #power-domain-cells = <0>;
+
+ pd_a4s: a4s@10 {
+ reg = <10>;
+ #address-cells = <1>;
+ #size-cells = <0>;
+ #power-domain-cells = <0>;
+
+ pd_a3sp: a3sp@11 {
+ reg = <11>;
+ #power-domain-cells = <0>;
+ };
+ };
+
+ pd_a4su: a4su@20 {
+ reg = <20>;
+ #power-domain-cells = <0>;
+ };
+ };
+ };
+ };
+
+
+== PM Domain Consumers ==
+
+Hardware blocks belonging to a PM domain should contain a "power-domains"
+property that is a phandle pointing to the corresponding PM domain node.
+
+Example:
+
+ tpu: pwm@e6600000 {
+ compatible = "renesas,tpu-r8a7740", "renesas,tpu";
+ reg = <0xe6600000 0x100>;
+ clocks = <&mstp3_clks R8A7740_CLK_TPU0>;
+ power-domains = <&pd_a3sp>;
+ #pwm-cells = <3>;
+ };