-rw-r--r--templates/netapp_cdot_volumes.ini44
1 files changed, 44 insertions, 0 deletions
diff --git a/templates/netapp_cdot_volumes.ini b/templates/netapp_cdot_volumes.ini
new file mode 100644
index 0000000..92cc686
--- /dev/null
+++ b/templates/netapp_cdot_volumes.ini
@@ -0,0 +1,44 @@
+[vol-space.graph]
+check_command = "netapp_cdot_volume_status"
+
+[vol-space.metrics_filters]
+value = "$service_name_template$.perfdata.$vol$.check_cdot_volume_usage.space_used.value"
+max = "$service_name_template$.perfdata.$vol$.check_cdot_volume_usage.space_used.max"
+crit = "$service_name_template$.perfdata.$vol$.check_cdot_volume_usage.space_used.crit"
+warn = "$service_name_template$.perfdata.$vol$.check_cdot_volume_usage.space_used.warn"
+[vol-space.urlparams]
+areaAlpha = "0.5"
+areaMode = "first"
+lineWidth = "2"
+min = "0"
+title = "Disk $vol$ Space used"
+yUnitSystem = "binary"
+
+[vol-space.functions]
+value = "alias(color($metric$, '#1a7dd7'), 'Used (bytes)')"
+max = "alias(color($metric$, '#cfd7e6'), 'Size (bytes)')"
+crit = "alias(color($metric$, '#ff0000'), 'Crit (bytes)')"
+warn = "alias(color($metric$, '#ff8d00'), 'Warn (bytes)')"
+
+[disk-inode.graph]
+check_command = "netapp_cdot_volume_status"
+
+[disk-inode.metrics_filters]
+value = "$service_name_template$.perfdata.$disk$.check_cdot_volume_usage.inode_used.value"
+max = "$service_name_template$.perfdata.$disk$.check_cdot_volume_usage.inode_used.max"
+crit = "$service_name_template$.perfdata.$disk$.check_cdot_volume_usage.inode_used.crit"
+warn = "$service_name_template$.perfdata.$disk$.check_cdot_volume_usage.inode_used.warn"
+
+[disk-inode.urlparams]
+areaAlpha = "0.5"
+areaMode = "first"
+lineWidth = "2"
+min = "0"
+title = "Disk $disk$ Inodes used"
+
+[disk-inode.functions]
+value = "alias(color($metric$, '#1a7dd7'), 'Used Inodes')"
+max = "alias(color($metric$, '#cfd7e6'), 'Max Inodes')"
+crit = "alias(color($metric$, '#ff0000'), 'Crit Inodes')"