diff options
author | Daniel Baumann <daniel.baumann@progress-linux.org> | 2024-04-28 12:44:18 +0000 |
---|---|---|
committer | Daniel Baumann <daniel.baumann@progress-linux.org> | 2024-04-28 12:44:18 +0000 |
commit | 23be945fd2810ee82e3a23cbcd2352c9bda43d4f (patch) | |
tree | dd511b321f308264952cffb005a4288ea4e478e6 /templates/netapp_cdot_volumes.ini | |
parent | Initial commit. (diff) | |
download | icingaweb2-module-graphite-upstream.tar.xz icingaweb2-module-graphite-upstream.zip |
Adding upstream version 1.2.2.upstream/1.2.2upstream
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'templates/netapp_cdot_volumes.ini')
-rw-r--r-- | templates/netapp_cdot_volumes.ini | 44 |
1 files changed, 44 insertions, 0 deletions
diff --git a/templates/netapp_cdot_volumes.ini b/templates/netapp_cdot_volumes.ini new file mode 100644 index 0000000..92cc686 --- /dev/null +++ b/templates/netapp_cdot_volumes.ini @@ -0,0 +1,44 @@ +[vol-space.graph] +check_command = "netapp_cdot_volume_status" + +[vol-space.metrics_filters] +value = "$service_name_template$.perfdata.$vol$.check_cdot_volume_usage.space_used.value" +max = "$service_name_template$.perfdata.$vol$.check_cdot_volume_usage.space_used.max" +crit = "$service_name_template$.perfdata.$vol$.check_cdot_volume_usage.space_used.crit" +warn = "$service_name_template$.perfdata.$vol$.check_cdot_volume_usage.space_used.warn" +[vol-space.urlparams] +areaAlpha = "0.5" +areaMode = "first" +lineWidth = "2" +min = "0" +title = "Disk $vol$ Space used" +yUnitSystem = "binary" + +[vol-space.functions] +value = "alias(color($metric$, '#1a7dd7'), 'Used (bytes)')" +max = "alias(color($metric$, '#cfd7e6'), 'Size (bytes)')" +crit = "alias(color($metric$, '#ff0000'), 'Crit (bytes)')" +warn = "alias(color($metric$, '#ff8d00'), 'Warn (bytes)')" + +[disk-inode.graph] +check_command = "netapp_cdot_volume_status" + +[disk-inode.metrics_filters] +value = "$service_name_template$.perfdata.$disk$.check_cdot_volume_usage.inode_used.value" +max = "$service_name_template$.perfdata.$disk$.check_cdot_volume_usage.inode_used.max" +crit = "$service_name_template$.perfdata.$disk$.check_cdot_volume_usage.inode_used.crit" +warn = "$service_name_template$.perfdata.$disk$.check_cdot_volume_usage.inode_used.warn" + +[disk-inode.urlparams] +areaAlpha = "0.5" +areaMode = "first" +lineWidth = "2" +min = "0" +title = "Disk $disk$ Inodes used" + +[disk-inode.functions] +value = "alias(color($metric$, '#1a7dd7'), 'Used Inodes')" +max = "alias(color($metric$, '#cfd7e6'), 'Max Inodes')" +crit = "alias(color($metric$, '#ff0000'), 'Crit Inodes')" +warn = "alias(color($metric$, '#ff8d00'), 'Warn Inodes')" + |