summaryrefslogtreecommitdiffstats
path: root/Documentation/devicetree/bindings/regulator/vctrl.txt
diff options
context:
space:
mode:
authorDaniel Baumann <daniel.baumann@progress-linux.org>2024-04-07 18:49:45 +0000
committerDaniel Baumann <daniel.baumann@progress-linux.org>2024-04-07 18:49:45 +0000
commit2c3c1048746a4622d8c89a29670120dc8fab93c4 (patch)
tree848558de17fb3008cdf4d861b01ac7781903ce39 /Documentation/devicetree/bindings/regulator/vctrl.txt
parentInitial commit. (diff)
downloadlinux-2c3c1048746a4622d8c89a29670120dc8fab93c4.tar.xz
linux-2c3c1048746a4622d8c89a29670120dc8fab93c4.zip
Adding upstream version 6.1.76.upstream/6.1.76
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'Documentation/devicetree/bindings/regulator/vctrl.txt')
-rw-r--r--Documentation/devicetree/bindings/regulator/vctrl.txt49
1 files changed, 49 insertions, 0 deletions
diff --git a/Documentation/devicetree/bindings/regulator/vctrl.txt b/Documentation/devicetree/bindings/regulator/vctrl.txt
new file mode 100644
index 000000000..601328d7f
--- /dev/null
+++ b/Documentation/devicetree/bindings/regulator/vctrl.txt
@@ -0,0 +1,49 @@
+Bindings for Voltage controlled regulators
+==========================================
+
+Required properties:
+--------------------
+- compatible : must be "vctrl-regulator".
+- regulator-min-microvolt : smallest voltage consumers may set
+- regulator-max-microvolt : largest voltage consumers may set
+- ctrl-supply : The regulator supplying the control voltage.
+- ctrl-voltage-range : an array of two integer values describing the range
+ (min/max) of the control voltage. The values specify
+ the control voltage needed to generate the corresponding
+ regulator-min/max-microvolt output voltage.
+
+Optional properties:
+--------------------
+- ovp-threshold-percent : overvoltage protection (OVP) threshold of the
+ regulator in percent. Some regulators have an OVP
+ circuitry which shuts down the regulator when the
+ actual output voltage deviates beyond a certain
+ margin from the expected value for a given control
+ voltage. On larger voltage decreases this can occur
+ undesiredly since the output voltage does not adjust
+ inmediately to changes in the control voltage. To
+ avoid this situation the vctrl driver breaks down
+ larger voltage decreases into multiple steps, where
+ each step is within the OVP threshold.
+- min-slew-down-rate : Describes how slowly the regulator voltage will decay
+ down in the worst case (lightest expected load).
+ Specified in uV / us (like main regulator ramp rate).
+ This value is required when ovp-threshold-percent is
+ specified.
+
+Example:
+
+ vctrl-reg {
+ compatible = "vctrl-regulator";
+ regulator-name = "vctrl_reg";
+
+ ctrl-supply = <&ctrl_reg>;
+
+ regulator-min-microvolt = <800000>;
+ regulator-max-microvolt = <1500000>;
+
+ ctrl-voltage-range = <200000 500000>;
+
+ min-slew-down-rate = <225>;
+ ovp-threshold-percent = <16>;
+ };