diff options
author | Daniel Baumann <daniel.baumann@progress-linux.org> | 2024-04-27 18:24:20 +0000 |
---|---|---|
committer | Daniel Baumann <daniel.baumann@progress-linux.org> | 2024-04-27 18:24:20 +0000 |
commit | 483eb2f56657e8e7f419ab1a4fab8dce9ade8609 (patch) | |
tree | e5d88d25d870d5dedacb6bbdbe2a966086a0a5cf /src/spdk/test/spdkcli/vhost.sh | |
parent | Initial commit. (diff) | |
download | ceph-upstream.tar.xz ceph-upstream.zip |
Adding upstream version 14.2.21.upstream/14.2.21upstream
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'src/spdk/test/spdkcli/vhost.sh')
-rwxr-xr-x | src/spdk/test/spdkcli/vhost.sh | 106 |
1 files changed, 106 insertions, 0 deletions
diff --git a/src/spdk/test/spdkcli/vhost.sh b/src/spdk/test/spdkcli/vhost.sh new file mode 100755 index 00000000..c479857e --- /dev/null +++ b/src/spdk/test/spdkcli/vhost.sh @@ -0,0 +1,106 @@ +#!/usr/bin/env bash +set -xe + +MATCH_FILE="spdkcli_vhost.test" +SPDKCLI_BRANCH="/" +testdir=$(readlink -f $(dirname $0)) +. $testdir/../json_config/common.sh +. $testdir/common.sh + +timing_enter spdk_cli_vhost +trap 'on_error_exit' ERR +timing_enter run_spdk_tgt +run_spdk_tgt +timing_exit run_spdk_tgt + +timing_enter spdkcli_create_bdevs_config +$spdkcli_job "/bdevs/malloc create 32 512 Malloc0" "Malloc0" True +$spdkcli_job "/bdevs/malloc create 32 512 Malloc1" "Malloc1" True +$spdkcli_job "/bdevs/malloc create 32 512 Malloc2" "Malloc2" True +$spdkcli_job "/bdevs/malloc create 32 4096 Malloc3" "Malloc3" True +$spdkcli_job "/bdevs/error create Malloc1" "EE_Malloc1" True +$spdkcli_job "/bdevs/null create null_bdev 32 512" "null_bdev" True +dd if=/dev/zero of=/tmp/sample_aio bs=2048 count=5000 +$spdkcli_job "/bdevs/aio create sample /tmp/sample_aio 512" "sample" True +trtype=$($SPDKCLI_BUILD_DIR/scripts/gen_nvme.sh --json | jq -r '.config[].params | select(.name=="Nvme0").trtype') +traddr=$($SPDKCLI_BUILD_DIR/scripts/gen_nvme.sh --json | jq -r '.config[].params | select(.name=="Nvme0").traddr') +$spdkcli_job "/bdevs/nvme create Nvme0 $trtype $traddr" "Nvme0" True +$spdkcli_job "/bdevs/split_disk split_bdev Nvme0n1 4" "Nvme0n1p0" True +timing_exit spdkcli_create_bdevs_config + +timing_enter spdkcli_create_lvols_config +$spdkcli_job "/lvol_stores create lvs Malloc0" "lvs" True +$spdkcli_job "/bdevs/logical_volume create lvol 16 lvs" "lvs/lvol" True +timing_exit spdkcli_create_lvols_config + +timing_enter spdkcli_create_vhosts_config +$spdkcli_job "vhost/block create vhost_blk1 Nvme0n1p0" "Nvme0n1p0" True +$spdkcli_job "vhost/block create vhost_blk2 Nvme0n1p1 0x2 readonly" "Nvme0n1p1" True +$spdkcli_job "vhost/scsi create vhost_scsi1" "vhost_scsi1" True +$spdkcli_job "vhost/scsi create vhost_scsi2" "vhost_scsi2" True +$spdkcli_job "vhost/scsi/vhost_scsi1 add_lun 0 Malloc2" "Malloc2" True +$spdkcli_job "vhost/scsi/vhost_scsi2 add_lun 0 Malloc3" "Malloc3" True +$spdkcli_job "vhost/scsi/vhost_scsi2 add_lun 1 Nvme0n1p2" "Nvme0n1p2" True +$spdkcli_job "vhost/scsi/vhost_scsi2 add_lun 2 Nvme0n1p3" "Nvme0n1p3" True +timing_exit spdkcli_create_vhosts_config + +timing_enter spdkcli_check_match +check_match +timing_exit spdkcli_check_match + +timing_enter spdkcli_save_config +$spdkcli_job "save_config $testdir/config.json" +$spdkcli_job "save_subsystem_config $testdir/config_bdev.json bdev" +$spdkcli_job "save_subsystem_config $testdir/config_vhost.json vhost" +timing_exit spdkcli_save_config + +timing_enter spdkcli_check_match_details +$SPDKCLI_BUILD_DIR/scripts/spdkcli.py bdevs/split_disk/Nvme0n1p0 show_details | jq -r -S '.' > $testdir/match_files/spdkcli_details_vhost.test +$SPDKCLI_BUILD_DIR/test/app/match/match -v $testdir/match_files/spdkcli_details_vhost.test.match +rm -f $testdir/match_files/spdkcli_details_vhost.test +timing_exit spdkcli_check_match_details + +timing_enter spdkcli_clear_config +$spdkcli_job "vhost/scsi/vhost_scsi2 remove_target 2" "Nvme0n1p3" +$spdkcli_job "vhost/scsi/vhost_scsi2 remove_target 1" "Nvme0n1p2" +$spdkcli_job "vhost/scsi/vhost_scsi2 remove_target 0" "Malloc3" +$spdkcli_job "vhost/scsi/vhost_scsi1 remove_target 0" "Malloc2" +$spdkcli_job "vhost/scsi delete vhost_scsi2" "vhost_scsi2" +$spdkcli_job "vhost/scsi delete vhost_scsi1" "vhost_scsi1" +$spdkcli_job "vhost/block delete vhost_blk2" "vhost_blk2" +$spdkcli_job "vhost/block delete vhost_blk1" "vhost_blk1" +$spdkcli_job "/bdevs/split_disk destruct_split_bdev Nvme0n1" "Nvme0n1p0" +$spdkcli_job "/bdevs/aio delete sample" "sample" +$spdkcli_job "/bdevs/nvme delete Nvme0" "Nvme0" +$spdkcli_job "/bdevs/null delete null_bdev" "null_bdev" +$spdkcli_job "/bdevs/logical_volume delete lvs/lvol" "lvs/lvol" +$spdkcli_job "/lvol_stores delete lvs" "lvs" +$spdkcli_job "/bdevs/malloc delete Malloc0" "Malloc0" +$spdkcli_job "/bdevs/malloc delete Malloc1" "Malloc1" +$spdkcli_job "/bdevs/malloc delete Malloc2" "Malloc2" +$spdkcli_job "/bdevs/malloc delete Malloc3" "Malloc3" +timing_exit spdkcli_clear_config + +timing_enter spdkcli_load_config +$spdkcli_job "load_config $testdir/config.json" +$spdkcli_job "/lvol_stores create lvs Malloc0" "lvs" True +$spdkcli_job "/bdevs/logical_volume create lvol 16 lvs" "lvs/lvol" True +check_match +$spdk_clear_config_py clear_config +# FIXME: remove this sleep when NVMe driver will be fixed to wait for reset to complete +sleep 2 +$spdkcli_job "load_subsystem_config $testdir/config_bdev.json" +$spdkcli_job "load_subsystem_config $testdir/config_vhost.json" +$spdkcli_job "/lvol_stores create lvs Malloc0" "lvs" True +$spdkcli_job "/bdevs/logical_volume create lvol 16 lvs" "lvs/lvol" True +check_match +rm -f $testdir/config.json +rm -f $testdir/config_bdev.json +rm -f $testdir/config_vhost.json +rm -f /tmp/sample_aio +timing_exit spdkcli_load_config + +killprocess $spdk_tgt_pid + +timing_exit spdk_cli_vhost +report_test_completion spdk_cli_vhost |