@@ -0,0 +1,382 @@
+.. BSD LICENSE
+ Copyright (c) 2017, Cisco Systems, Inc.
+ All rights reserved.
+
+ Redistribution and use in source and binary forms, with or without
+ modification, are permitted provided that the following conditions
+ are met:
+
+ 1. Redistributions of source code must retain the above copyright
+ notice, this list of conditions and the following disclaimer.
+
+ 2. Redistributions in binary form must reproduce the above copyright
+ notice, this list of conditions and the following disclaimer in
+ the documentation and/or other materials provided with the
+ distribution.
+
+ THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
+ "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
+ LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
+ FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
+ COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT,
+ INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING,
+ BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
+ LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
+ CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
+ LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN
+ ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
+ POSSIBILITY OF SUCH DAMAGE.
+
+ENIC Poll Mode Driver
+=====================
+
+ENIC PMD is the DPDK poll-mode driver for the Cisco System Inc. VIC Ethernet
+NICs. These adapters are also referred to as vNICs below. If you are running
+or would like to run DPDK software applications on Cisco UCS servers using
+Cisco VIC adapters the following documentation is relevant.
+
+How to obtain ENIC PMD integrated DPDK
+--------------------------------------
+
+ENIC PMD support is integrated into the DPDK suite. dpdk-<version>.tar.gz
+should be downloaded from http://dpdk.org
+
+
+Configuration information
+-------------------------
+
+- **DPDK Configuration Parameters**
+
+ The following configuration options are available for the ENIC PMD:
+
+ - **CONFIG_RTE_LIBRTE_ENIC_PMD** (default y): Enables or disables inclusion
+ of the ENIC PMD driver in the DPDK compilation.
+
+ - **CONFIG_RTE_LIBRTE_ENIC_DEBUG** (default n): Enables or disables debug
+ logging within the ENIC PMD driver.
+
+- **vNIC Configuration Parameters**
+
+ - **Number of Queues**
+
+ The maximum number of receive queues (RQs), work queues (WQs) and
+ completion queues (CQs) are configurable on a per vNIC basis
+ through the Cisco UCS Manager (CIMC or UCSM).
+
+ These values should be configured as follows:
+
+ - The number of WQs should be greater or equal to the value of the
+ expected nb_tx_q parameter in the call to the
+ rte_eth_dev_configure()
+
+ - The number of RQs configured in the vNIC should be greater or
+ equal to *twice* the value of the expected nb_rx_q parameter in
+ the call to rte_eth_dev_configure(). With the addition of Rx
+ scatter, a pair of RQs on the vnic is needed for each receive
+ queue used by DPDK, even if Rx scatter is not being used.
+ Having a vNIC with only 1 RQ is not a valid configuration, and
+ will fail with an error message.
+
+ - The number of CQs should set so that there is one CQ for each
+ WQ, and one CQ for each pair of RQs.
+
+ For example: If the application requires 3 Rx queues, and 3 Tx
+ queues, the vNIC should be configured to have at least 3 WQs, 6
+ RQs (3 pairs), and 6 CQs (3 for use by WQs + 3 for use by the 3
+ pairs of RQs).
+
+ - **Size of Queues**
+
+ Likewise, the number of receive and transmit descriptors are configurable on
+ a per vNIC bases via the UCS Manager and should be greater than or equal to
+ the nb_rx_desc and nb_tx_desc parameters expected to be used in the calls
+ to rte_eth_rx_queue_setup() and rte_eth_tx_queue_setup() respectively.
+ An application requesting more than the set size will be limited to that
+ size.
+
+ Unless there is a lack of resources due to creating many vNICs, it
+ is recommended that the WQ and RQ sizes be set to the maximum. This
+ gives the application the greatest amount of flexibility in its
+ queue configuration.
+
+ - *Note*: Since the introduction of Rx scatter, for performance
+ reasons, this PMD uses two RQs on the vNIC per receive queue in
+ DPDK. One RQ holds descriptors for the start of a packet the
+ second RQ holds the descriptors for the rest of the fragments of
+ a packet. This means that the nb_rx_desc parameter to
+ rte_eth_rx_queue_setup() can be a greater than 4096. The exact
+ amount will depend on the size of the mbufs being used for
+ receives, and the MTU size.
+
+ For example: If the mbuf size is 2048, and the MTU is 9000, then
+ receiving a full size packet will take 5 descriptors, 1 from the
+ start of packet queue, and 4 from the second queue. Assuming
+ that the RQ size was set to the maximum of 4096, then the
+ application can specify up to 1024 + 4096 as the nb_rx_desc
+ parameter to rte_eth_rx_queue_setup().
+
+ - **Interrupts**
+
+ Only one interrupt per vNIC interface should be configured in the UCS
+ manager regardless of the number receive/transmit queues. The ENIC PMD
+ uses this interrupt to get information about link status and errors
+ in the fast path.
+
+.. _enic-flow-director:
+
+Flow director support
+---------------------
+
+Advanced filtering support was added to 1300 series VIC firmware starting
+with version 2.0.13 for C-series UCS servers and version 3.1.2 for UCSM
+managed blade servers. In order to enable advanced filtering the 'Advanced
+filter' radio button should be enabled via CIMC or UCSM followed by a reboot
+of the server.
+
+With advanced filters, perfect matching of all fields of IPv4, IPv6 headers
+as well as TCP, UDP and SCTP L4 headers is available through flow director.
+Masking of these fields for partial match is also supported.
+
+Without advanced filter support, the flow director is limited to IPv4
+perfect filtering of the 5-tuple with no masking of fields supported.
+
+SR-IOV mode utilization
+-----------------------
+
+UCS blade servers configured with dynamic vNIC connection policies in UCS
+manager are capable of supporting assigned devices on virtual machines (VMs)
+through a KVM hypervisor. Assigned devices, also known as 'passthrough'
+devices, are SR-IOV virtual functions (VFs) on the host which are exposed
+to VM instances.
+
+The Cisco Virtual Machine Fabric Extender (VM-FEX) gives the VM a dedicated
+interface on the Fabric Interconnect (FI). Layer 2 switching is done at
+the FI. This may eliminate the requirement for software switching on the
+host to route intra-host VM traffic.
+
+Please refer to `Creating a Dynamic vNIC Connection Policy
+<http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/vm_fex/vmware/gui/config_guide/b_GUI_VMware_VM-FEX_UCSM_Configuration_Guide/b_GUI_VMware_VM-FEX_UCSM_Configuration_Guide_chapter_010.html#task_433E01651F69464783A68E66DA8A47A5>`_
+for information on configuring SR-IOV Adapter policies using UCS manager.
+
+Once the policies are in place and the host OS is rebooted, VFs should be
+visible on the host, E.g.:
+
+.. code-block:: console
+
+ # lspci | grep Cisco | grep Ethernet
+ 0d:00.0 Ethernet controller: Cisco Systems Inc VIC Ethernet NIC (rev a2)
+ 0d:00.1 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
+ 0d:00.2 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
+ 0d:00.3 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
+ 0d:00.4 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
+ 0d:00.5 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
+ 0d:00.6 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
+ 0d:00.7 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
+
+Enable Intel IOMMU on the host and install KVM and libvirt. A VM instance should
+be created with an assigned device. When using libvirt, this configuration can
+be done within the domain (i.e. VM) config file. For example this entry maps
+host VF 0d:00:01 into the VM.
+
+.. code-block:: console
+
+ <interface type='hostdev' managed='yes'>
+ <mac address='52:54:00:ac:ff:b6'/>
+ <source>
+ <address type='pci' domain='0x0000' bus='0x0d' slot='0x00' function='0x1'/>
+ </source>
+
+Alternatively, the configuration can be done in a separate file using the
+``network`` keyword. These methods are described in the libvirt documentation for
+`Network XML format <https://libvirt.org/formatnetwork.html>`_.
+
+When the VM instance is started, the ENIC KVM driver will bind the host VF to
+vfio, complete provisioning on the FI and bring up the link.
+
+.. note::
+
+ It is not possible to use a VF directly from the host because it is not
+ fully provisioned until the hypervisor brings up the VM that it is assigned
+ to.
+
+In the VM instance, the VF will now be visible. E.g., here the VF 00:04.0 is
+seen on the VM instance and should be available for binding to a DPDK.
+
+.. code-block:: console
+
+ # lspci | grep Ether
+ 00:04.0 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
+
+Follow the normal DPDK install procedure, binding the VF to either ``igb_uio``
+or ``vfio`` in non-IOMMU mode.
+
+Please see :ref:`Limitations <enic_limitations>` for limitations in
+the use of SR-IOV.
+
+.. _enic_limitations:
+
+Limitations
+-----------
+
+- **VLAN 0 Priority Tagging**
+
+ If a vNIC is configured in TRUNK mode by the UCS manager, the adapter will
+ priority tag egress packets according to 802.1Q if they were not already
+ VLAN tagged by software. If the adapter is connected to a properly configured
+ switch, there will be no unexpected behavior.
+
+ In test setups where an Ethernet port of a Cisco adapter in TRUNK mode is
+ connected point-to-point to another adapter port or connected though a router
+ instead of a switch, all ingress packets will be VLAN tagged. Programs such
+ as l3fwd which do not account for VLAN tags in packets will misbehave. The
+ solution is to enable VLAN stripping on ingress. The follow code fragment is
+ example of how to accomplish this:
+
+.. code-block:: console
+
+ vlan_offload = rte_eth_dev_get_vlan_offload(port);
+ vlan_offload |= ETH_VLAN_STRIP_OFFLOAD;
+ rte_eth_dev_set_vlan_offload(port, vlan_offload);
+
+- Limited flow director support on 1200 series and 1300 series Cisco VIC
+ adapters with old firmware. Please see :ref:`enic-flow-director`.
+
+- Flow director features are not supported on generation 1 Cisco VIC adapters
+ (M81KR and P81E)
+
+- **SR-IOV**
+
+ - KVM hypervisor support only. VMware has not been tested.
+ - Requires VM-FEX, and so is only available on UCS managed servers connected
+ to Fabric Interconnects. It is not on standalone C-Series servers.
+ - VF devices are not usable directly from the host. They can only be used
+ as assigned devices on VM instances.
+ - Currently, unbind of the ENIC kernel mode driver 'enic.ko' on the VM
+ instance may hang. As a workaround, enic.ko should blacklisted or removed
+ from the boot process.
+ - pci_generic cannot be used as the uio module in the VM. igb_uio or
+ vfio in non-IOMMU mode can be used.
+ - The number of RQs in UCSM dynamic vNIC configurations must be at least 2.
+ - The number of SR-IOV devices is limited to 256. Components on target system
+ might limit this number to fewer than 256.
+
+How to build the suite
+----------------------
+
+Refer to the document :ref:`compiling and testing a PMD for a NIC
+<pmd_build_and_test>` for details.
+
+By default the ENIC PMD library will be built into the DPDK library.
+
+For configuring and using UIO and VFIO frameworks, please refer to the
+documentation that comes with DPDK suite.
+
+Supported Cisco VIC adapters
+----------------------------
+
+ENIC PMD supports all recent generations of Cisco VIC adapters including:
+
+- VIC 1280
+- VIC 1240
+- VIC 1225
+- VIC 1285
+- VIC 1225T
+- VIC 1227
+- VIC 1227T
+- VIC 1380
+- VIC 1340
+- VIC 1385
+- VIC 1387
+
+Supported Operating Systems
+---------------------------
+
+Any Linux distribution fulfilling the conditions described in Dependencies
+section of DPDK documentation.
+
+Supported features
+------------------
+
+- Unicast, multicast and broadcast transmission and reception
+- Receive queue polling
+- Port Hardware Statistics
+- Hardware VLAN acceleration
+- IP checksum offload
+- Receive side VLAN stripping
+- Multiple receive and transmit queues
+- Flow Director ADD, UPDATE, DELETE, STATS operation support IPv4 and IPv6
+- Promiscuous mode
+- Setting RX VLAN (supported via UCSM/CIMC only)
+- VLAN filtering (supported via UCSM/CIMC only)
+- Execution of application by unprivileged system users
+- IPV4, IPV6 and TCP RSS hashing
+- Scattered Rx
+- MTU update
+- SR-IOV on UCS managed servers connected to Fabric Interconnects.
+
+Known bugs and unsupported features in this release
+---------------------------------------------------
+
+- Signature or flex byte based flow direction
+- Drop feature of flow direction
+- VLAN based flow direction
+- non-IPV4 flow direction
+- Setting of extended VLAN
+- UDP RSS hashing
+- MTU update only works if Scattered Rx mode is disabled
+
+Prerequisites
+-------------
+
+- Prepare the system as recommended by DPDK suite. This includes environment
+ variables, hugepages configuration, tool-chains and configuration
+- Insert vfio-pci kernel module using the command 'modprobe vfio-pci' if the
+ user wants to use VFIO framework
+- Insert uio kernel module using the command 'modprobe uio' if the user wants
+ to use UIO framework
+- DPDK suite should be configured based on the user's decision to use VFIO or
+ UIO framework
+- If the vNIC device(s) to be used is bound to the kernel mode Ethernet driver
+ use 'ifconfig' to bring the interface down. The dpdk-devbind.py tool can
+ then be used to unbind the device's bus id from the ENIC kernel mode driver.
+- Bind the intended vNIC to vfio-pci in case the user wants ENIC PMD to use
+ VFIO framework using dpdk-devbind.py.
+- Bind the intended vNIC to igb_uio in case the user wants ENIC PMD to use
+ UIO framework using dpdk-devbind.py.
+
+At this point the system should be ready to run DPDK applications. Once the
+application runs to completion, the vNIC can be detached from vfio-pci or
+igb_uio if necessary.
+
+Root privilege is required to bind and unbind vNICs to/from VFIO/UIO.
+VFIO framework helps an unprivileged user to run the applications.
+For an unprivileged user to run the applications on DPDK and ENIC PMD,
+it may be necessary to increase the maximum locked memory of the user.
+The following command could be used to do this.
+
+.. code-block:: console
+
+ sudo sh -c "ulimit -l <value in Kilo Bytes>"
+
+The value depends on the memory configuration of the application, DPDK and
+PMD. Typically, the limit has to be raised to higher than 2GB.
+e.g., 2621440
+
+The compilation of any unused drivers can be disabled using the
+configuration file in config/ directory (e.g., config/common_linuxapp).
+This would help in bringing down the time taken for building the
+libraries and the initialization time of the application.
+
+Additional Reference
+--------------------
+
+- http://www.cisco.com/c/en/us/products/servers-unified-computing
+
+Contact Information
+-------------------
+
+Any questions or bugs should be reported to DPDK community and to the ENIC PMD
+maintainers:
+
+- John Daley <johndale@cisco.com>
+- Nelson Escobar <neescoba@cisco.com>