diff --git a/src/spdk/test/nvmf/host/perf.sh b/src/spdk/test/nvmf/host/perf.sh
new file mode 100755
index 00000000..24faed5b
--- /dev/null
+++ b/src/spdk/test/nvmf/host/perf.sh
@@ -0,0 +1,95 @@
+#!/usr/bin/env bash
+
+testdir=$(readlink -f $(dirname $0))
+rootdir=$(readlink -f $testdir/../../..)
+source $rootdir/test/common/autotest_common.sh
+source $rootdir/test/nvmf/common.sh
+
+MALLOC_BDEV_SIZE=64
+MALLOC_BLOCK_SIZE=512
+
+rpc_py="$rootdir/scripts/rpc.py"
+
+set -e
+
+RDMA_IP_LIST=$(get_available_rdma_ips)
+NVMF_FIRST_TARGET_IP=$(echo "$RDMA_IP_LIST" | head -n 1)
+if [ -z $NVMF_FIRST_TARGET_IP ]; then
+ echo "no NIC for nvmf test"
+ exit 0
+fi
+
+timing_enter perf
+timing_enter start_nvmf_tgt
+
+$NVMF_APP -m 0xF -i 0 &
+nvmfpid=$!
+
+trap "process_shm --id $NVMF_APP_SHM_ID; killprocess $nvmfpid; exit 1" SIGINT SIGTERM EXIT
+
+waitforlisten $nvmfpid
+$rpc_py nvmf_create_transport -t RDMA -u 8192 -p 4
+$rootdir/scripts/gen_nvme.sh --json | $rpc_py load_subsystem_config
+timing_exit start_nvmf_tgt
+
+local_nvme_trid="trtype:PCIe traddr:"$($rpc_py get_subsystem_config bdev | jq -r '.[].params | select(.name=="Nvme0").traddr')
+bdevs="$bdevs $($rpc_py construct_malloc_bdev $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE)"
+
+if [ -n "$local_nvme_trid" ]; then
+ bdevs="$bdevs Nvme0n1"
+fi
+
+$rpc_py nvmf_subsystem_create nqn.2016-06.io.spdk:cnode1 -a -s SPDK00000000000001
+for bdev in $bdevs; do
+ $rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 $bdev
+done
+$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t rdma -a $NVMF_FIRST_TARGET_IP -s 4420
+
+# Test multi-process access to local NVMe device
+if [ -n "$local_nvme_trid" ]; then
+ $rootdir/examples/nvme/perf/perf -i 0 -q 32 -o 4096 -w randrw -M 50 -t 1 -r "$local_nvme_trid"
+fi
+
+$rootdir/examples/nvme/perf/perf -q 32 -o 4096 -w randrw -M 50 -t 1 -r "trtype:RDMA adrfam:IPv4 traddr:$NVMF_FIRST_TARGET_IP trsvcid:4420"
+sync
+$rpc_py delete_nvmf_subsystem nqn.2016-06.io.spdk:cnode1
+
+if [ $RUN_NIGHTLY -eq 1 ]; then
+ # Configure nvme devices with nvmf lvol_bdev backend
+ if [ -n "$local_nvme_trid" ]; then
+ ls_guid=$($rpc_py construct_lvol_store Nvme0n1 lvs_0)
+ get_lvs_free_mb $ls_guid
+ lb_guid=$($rpc_py construct_lvol_bdev -u $ls_guid lbd_0 $free_mb)
+
+ # Create lvol bdev for nested lvol stores
+ ls_nested_guid=$($rpc_py construct_lvol_store $lb_guid lvs_n_0)
+ get_lvs_free_mb $ls_nested_guid
+ lb_nested_guid=$($rpc_py construct_lvol_bdev -u $ls_nested_guid lbd_nest_0 $free_mb)
+ $rpc_py nvmf_subsystem_create nqn.2016-06.io.spdk:cnode1 -a -s SPDK00000000000001
+ for bdev in $lb_nested_guid; do
+ $rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 $bdev
+ done
+ $rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t rdma -a $NVMF_FIRST_TARGET_IP -s 4420
+ # Test perf as host with different io_size and qd_depth in nightly
+ qd_depth=("1" "128")
+ io_size=("512" "131072")
+ for qd in ${qd_depth[@]}; do
+ for o in ${io_size[@]}; do
+ $rootdir/examples/nvme/perf/perf -q $qd -o $o -w randrw -M 50 -t 10 -r "trtype:RDMA adrfam:IPv4 traddr:$NVMF_FIRST_TARGET_IP trsvcid:4420"
+ done
+ done
+
+ # Delete subsystems, lvol_bdev and destroy lvol_store.
+ $rpc_py delete_nvmf_subsystem nqn.2016-06.io.spdk:cnode1
+ $rpc_py destroy_lvol_bdev "$lb_nested_guid"
+ $rpc_py destroy_lvol_store -l lvs_n_0
+ $rpc_py destroy_lvol_bdev "$lb_guid"
+ $rpc_py destroy_lvol_store -l lvs_0
+ $rpc_py delete_nvme_controller Nvme0
+ fi
+fi
+
+trap - SIGINT SIGTERM EXIT
+
+killprocess $nvmfpid
+timing_exit perf