blob: c8b40794ea37856d974dc6249639c54f74b8ad78 (
plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
|
#!/usr/bin/env bash
testdir=$(readlink -f $(dirname $0))
rootdir=$(readlink -f $testdir/../../..)
source $rootdir/test/common/autotest_common.sh
source $rootdir/test/nvmf/common.sh
if [ -z "${DEPENDENCY_DIR}" ]; then
echo DEPENDENCY_DIR not defined!
exit 1
fi
spdk_nvme_cli="${DEPENDENCY_DIR}/nvme-cli"
MALLOC_BDEV_SIZE=64
MALLOC_BLOCK_SIZE=512
rpc_py="$rootdir/scripts/rpc.py"
set -e
# pass the parameter 'iso' to this script when running it in isolation to trigger rdma device initialization.
# e.g. sudo ./nvme_cli.sh iso
nvmftestinit $1
RDMA_IP_LIST=$(get_available_rdma_ips)
NVMF_FIRST_TARGET_IP=$(echo "$RDMA_IP_LIST" | head -n 1)
if [ -z $NVMF_FIRST_TARGET_IP ]; then
echo "no NIC for nvmf test"
exit 0
fi
timing_enter nvme_cli
timing_enter start_nvmf_tgt
$NVMF_APP -m 0xF &
nvmfpid=$!
trap "process_shm --id $NVMF_APP_SHM_ID; killprocess $nvmfpid; nvmftestfini $1; exit 1" SIGINT SIGTERM EXIT
waitforlisten $nvmfpid
$rpc_py nvmf_create_transport -t RDMA -u 8192 -p 4
timing_exit start_nvmf_tgt
bdevs="$($rpc_py construct_malloc_bdev $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE) "
bdevs+="$($rpc_py construct_malloc_bdev $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE)"
modprobe -v nvme-rdma
$rpc_py nvmf_subsystem_create nqn.2016-06.io.spdk:cnode1 -a -s SPDK00000000000001
for bdev in $bdevs; do
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 $bdev
done
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t rdma -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT
nvme connect -t rdma -n "nqn.2016-06.io.spdk:cnode1" -a "$NVMF_FIRST_TARGET_IP" -s "$NVMF_PORT"
waitforblk "nvme0n1"
waitforblk "nvme0n2"
nvme list
for ctrl in /dev/nvme?; do
nvme id-ctrl $ctrl
nvme smart-log $ctrl
done
for ns in /dev/nvme?n*; do
nvme id-ns $ns
done
nvme disconnect -n "nqn.2016-06.io.spdk:cnode1" || true
nvme disconnect -n "nqn.2016-06.io.spdk:cnode2" || true
if [ -d $spdk_nvme_cli ]; then
# Test spdk/nvme-cli NVMe-oF commands: discover, connect and disconnect
cd $spdk_nvme_cli
./nvme discover -t rdma -a $NVMF_FIRST_TARGET_IP -s "$NVMF_PORT"
nvme_num_before_connection=$(nvme list |grep "/dev/nvme*"|awk '{print $1}'|wc -l)
./nvme connect -t rdma -n "nqn.2016-06.io.spdk:cnode1" -a "$NVMF_FIRST_TARGET_IP" -s "$NVMF_PORT"
sleep 1
nvme_num=$(nvme list |grep "/dev/nvme*"|awk '{print $1}'|wc -l)
./nvme disconnect -n "nqn.2016-06.io.spdk:cnode1"
if [ $nvme_num -le $nvme_num_before_connection ]; then
echo "spdk/nvme-cli connect target devices failed"
exit 1
fi
fi
$rpc_py delete_nvmf_subsystem nqn.2016-06.io.spdk:cnode1
trap - SIGINT SIGTERM EXIT
nvmfcleanup
killprocess $nvmfpid
nvmftestfini $1
report_test_completion "nvmf_spdk_nvme_cli"
timing_exit nvme_cli
|