diff options
author | Daniel Baumann <daniel.baumann@progress-linux.org> | 2024-04-21 11:54:28 +0000 |
---|---|---|
committer | Daniel Baumann <daniel.baumann@progress-linux.org> | 2024-04-21 11:54:28 +0000 |
commit | e6918187568dbd01842d8d1d2c808ce16a894239 (patch) | |
tree | 64f88b554b444a49f656b6c656111a145cbbaa28 /src/spdk/test/nvmf/target/nmic.sh | |
parent | Initial commit. (diff) | |
download | ceph-e6918187568dbd01842d8d1d2c808ce16a894239.tar.xz ceph-e6918187568dbd01842d8d1d2c808ce16a894239.zip |
Adding upstream version 18.2.2.upstream/18.2.2
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'src/spdk/test/nvmf/target/nmic.sh')
-rwxr-xr-x | src/spdk/test/nvmf/target/nmic.sh | 56 |
1 files changed, 56 insertions, 0 deletions
diff --git a/src/spdk/test/nvmf/target/nmic.sh b/src/spdk/test/nvmf/target/nmic.sh new file mode 100755 index 000000000..6a967dc08 --- /dev/null +++ b/src/spdk/test/nvmf/target/nmic.sh @@ -0,0 +1,56 @@ +#!/usr/bin/env bash + +testdir=$(readlink -f $(dirname $0)) +rootdir=$(readlink -f $testdir/../../..) +source $rootdir/test/common/autotest_common.sh +source $rootdir/test/nvmf/common.sh + +MALLOC_BDEV_SIZE=64 +MALLOC_BLOCK_SIZE=512 + +rpc_py="$rootdir/scripts/rpc.py" + +nvmftestinit +nvmfappstart -m 0xF + +NVMF_SECOND_TARGET_IP=$(echo "$RDMA_IP_LIST" | sed -n 2p) + +$rpc_py nvmf_create_transport $NVMF_TRANSPORT_OPTS -u 8192 + +# Create subsystems +$rpc_py bdev_malloc_create $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE -b Malloc0 +$rpc_py nvmf_create_subsystem nqn.2016-06.io.spdk:cnode1 -a -s $NVMF_SERIAL +$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 Malloc0 +$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s "$NVMF_PORT" + +echo "test case1: single bdev can't be used in multiple subsystems" +$rpc_py nvmf_create_subsystem nqn.2016-06.io.spdk:cnode2 -a -s SPDK2 +$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode2 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s "$NVMF_PORT" +nmic_status=0 +$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode2 Malloc0 || nmic_status=$? + +if [ $nmic_status -eq 0 ]; then + echo " Adding namespace passed - failure expected." + nvmftestfini + exit 1 +else + echo " Adding namespace failed - expected result." +fi + +echo "test case2: host connect to nvmf target in multiple paths" +if [ -n "$NVMF_SECOND_TARGET_IP" ]; then + $rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_SECOND_TARGET_IP -s $NVMF_PORT + + nvme connect -t $TEST_TRANSPORT -n "nqn.2016-06.io.spdk:cnode1" -a "$NVMF_FIRST_TARGET_IP" -s "$NVMF_PORT" + nvme connect -t $TEST_TRANSPORT -n "nqn.2016-06.io.spdk:cnode1" -a "$NVMF_SECOND_TARGET_IP" -s "$NVMF_PORT" + + waitforserial "$NVMF_SERIAL" + + $rootdir/scripts/fio.py -p nvmf -i 4096 -d 1 -t write -r 1 -v +fi + +nvme disconnect -n "nqn.2016-06.io.spdk:cnode1" || true + +trap - SIGINT SIGTERM EXIT + +nvmftestfini |