diff options
Diffstat (limited to 'src/spdk/test/nvmf/host/perf.sh')
-rwxr-xr-x | src/spdk/test/nvmf/host/perf.sh | 93 |
1 files changed, 93 insertions, 0 deletions
diff --git a/src/spdk/test/nvmf/host/perf.sh b/src/spdk/test/nvmf/host/perf.sh new file mode 100755 index 000000000..69fa28f0b --- /dev/null +++ b/src/spdk/test/nvmf/host/perf.sh @@ -0,0 +1,93 @@ +#!/usr/bin/env bash + +testdir=$(readlink -f $(dirname $0)) +rootdir=$(readlink -f $testdir/../../..) +source $rootdir/test/common/autotest_common.sh +source $rootdir/test/nvmf/common.sh + +MALLOC_BDEV_SIZE=64 +MALLOC_BLOCK_SIZE=512 + +rpc_py="$rootdir/scripts/rpc.py" + +nvmftestinit +nvmfappstart -m 0xF + +$rootdir/scripts/gen_nvme.sh --json | $rpc_py load_subsystem_config + +local_nvme_trid="trtype:PCIe traddr:"$($rpc_py framework_get_config bdev | jq -r '.[].params | select(.name=="Nvme0").traddr') +bdevs="$bdevs $($rpc_py bdev_malloc_create $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE)" + +if [ -n "$local_nvme_trid" ]; then + bdevs="$bdevs Nvme0n1" +fi + +$rpc_py nvmf_create_transport $NVMF_TRANSPORT_OPTS +$rpc_py nvmf_create_subsystem nqn.2016-06.io.spdk:cnode1 -a -s SPDK00000000000001 +for bdev in $bdevs; do + $rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 $bdev +done +$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT + +# Test multi-process access to local NVMe device +if [ -n "$local_nvme_trid" ]; then + if [ $SPDK_RUN_NON_ROOT -eq 1 ]; then + perf_app="sudo -u $(logname) $SPDK_EXAMPLE_DIR/perf" + else + perf_app="$SPDK_EXAMPLE_DIR/perf" + fi + $perf_app -i $NVMF_APP_SHM_ID -q 32 -o 4096 -w randrw -M 50 -t 1 -r "$local_nvme_trid" +fi + +$SPDK_EXAMPLE_DIR/perf -q 1 -o 4096 -w randrw -M 50 -t 1 -r "trtype:$TEST_TRANSPORT adrfam:IPv4 traddr:$NVMF_FIRST_TARGET_IP trsvcid:$NVMF_PORT" +$SPDK_EXAMPLE_DIR/perf -q 32 -o 4096 -w randrw -M 50 -t 1 -r "trtype:$TEST_TRANSPORT adrfam:IPv4 traddr:$NVMF_FIRST_TARGET_IP trsvcid:$NVMF_PORT" +$SPDK_EXAMPLE_DIR/perf -q 128 -o 262144 -w randrw -M 50 -t 2 -r "trtype:$TEST_TRANSPORT adrfam:IPv4 traddr:$NVMF_FIRST_TARGET_IP trsvcid:$NVMF_PORT" +sync +$rpc_py nvmf_delete_subsystem nqn.2016-06.io.spdk:cnode1 + +if [ $RUN_NIGHTLY -eq 1 ]; then + # Configure nvme devices with nvmf lvol_bdev backend + if [ -n "$local_nvme_trid" ]; then + ls_guid=$($rpc_py bdev_lvol_create_lvstore Nvme0n1 lvs_0) + get_lvs_free_mb $ls_guid + # We don't need to create an lvol larger than 20G for this test. + # decreasing the size of the nested lvol allows us to take less time setting up + #before running I/O. + if [ $free_mb -gt 20480 ]; then + free_mb=20480 + fi + lb_guid=$($rpc_py bdev_lvol_create -u $ls_guid lbd_0 $free_mb) + + # Create lvol bdev for nested lvol stores + ls_nested_guid=$($rpc_py bdev_lvol_create_lvstore $lb_guid lvs_n_0) + get_lvs_free_mb $ls_nested_guid + if [ $free_mb -gt 20480 ]; then + free_mb=20480 + fi + lb_nested_guid=$($rpc_py bdev_lvol_create -u $ls_nested_guid lbd_nest_0 $free_mb) + $rpc_py nvmf_create_subsystem nqn.2016-06.io.spdk:cnode1 -a -s SPDK00000000000001 + for bdev in $lb_nested_guid; do + $rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 $bdev + done + $rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT + # Test perf as host with different io_size and qd_depth in nightly + qd_depth=("1" "32" "128") + io_size=("512" "131072") + for qd in "${qd_depth[@]}"; do + for o in "${io_size[@]}"; do + $SPDK_EXAMPLE_DIR/perf -q $qd -o $o -w randrw -M 50 -t 10 -r "trtype:$TEST_TRANSPORT adrfam:IPv4 traddr:$NVMF_FIRST_TARGET_IP trsvcid:$NVMF_PORT" + done + done + + # Delete subsystems, lvol_bdev and destroy lvol_store. + $rpc_py nvmf_delete_subsystem nqn.2016-06.io.spdk:cnode1 + $rpc_py bdev_lvol_delete "$lb_nested_guid" + $rpc_py bdev_lvol_delete_lvstore -l lvs_n_0 + $rpc_py bdev_lvol_delete "$lb_guid" + $rpc_py bdev_lvol_delete_lvstore -l lvs_0 + fi +fi + +trap - SIGINT SIGTERM EXIT + +nvmftestfini |