1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
|
.. SPDX-License-Identifier: BSD-3-Clause
Copyright(c) 2015-2017 Netronome Systems, Inc. All rights reserved.
All rights reserved.
NFP poll mode driver library
============================
Netronome's sixth generation of flow processors pack 216 programmable
cores and over 100 hardware accelerators that uniquely combine packet,
flow, security and content processing in a single device that scales
up to 400-Gb/s.
This document explains how to use DPDK with the Netronome Poll Mode
Driver (PMD) supporting Netronome's Network Flow Processor 6xxx
(NFP-6xxx) and Netronome's Flow Processor 4xxx (NFP-4xxx).
NFP is a SRIOV capable device and the PMD driver supports the physical
function (PF) and the virtual functions (VFs).
Dependencies
------------
Before using the Netronome's DPDK PMD some NFP configuration,
which is not related to DPDK, is required. The system requires
installation of **Netronome's BSP (Board Support Package)** along
with a specific NFP firmware application. Netronome's NSP ABI
version should be 0.20 or higher.
If you have a NFP device you should already have the code and
documentation for this configuration. Contact
**support@netronome.com** to obtain the latest available firmware.
The NFP Linux netdev kernel driver for VFs has been a part of the
vanilla kernel since kernel version 4.5, and support for the PF
since kernel version 4.11. Support for older kernels can be obtained
on Github at
**https://github.com/Netronome/nfp-drv-kmods** along with the build
instructions.
NFP PMD needs to be used along with UIO ``igb_uio`` or VFIO (``vfio-pci``)
Linux kernel driver.
Building the software
---------------------
Netronome's PMD code is provided in the **drivers/net/nfp** directory.
Although NFP PMD has Netronome´s BSP dependencies, it is possible to
compile it along with other DPDK PMDs even if no BSP was installed previously.
Of course, a DPDK app will require such a BSP installed for using the
NFP PMD, along with a specific NFP firmware application.
Default PMD configuration is at the **common_linux configuration** file:
- **CONFIG_RTE_LIBRTE_NFP_PMD=y**
Once the DPDK is built all the DPDK apps and examples include support for
the NFP PMD.
Driver compilation and testing
------------------------------
Refer to the document :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
for details.
Using the PF
------------
NFP PMD supports using the NFP PF as another DPDK port, but it does not
have any functionality for controlling VFs. In fact, it is not possible to use
the PMD with the VFs if the PF is being used by DPDK, that is, with the NFP PF
bound to ``igb_uio`` or ``vfio-pci`` kernel drivers. Future DPDK versions will
have a PMD able to work with the PF and VFs at the same time and with the PF
implementing VF management along with other PF-only functionalities/offloads.
The PMD PF has extra work to do which will delay the DPDK app initialization
like uploading the firmware and configure the Link state properly when starting or
stopping a PF port. Since DPDK 18.05 the firmware upload happens when
a PF is initialized, which was not always true with older DPDK versions.
Depending on the Netronome product installed in the system, firmware files
should be available under ``/lib/firmware/netronome``. DPDK PMD supporting the
PF looks for a firmware file in this order:
1) First try to find a firmware image specific for this device using the
NFP serial number:
serial-00-15-4d-12-20-65-10-ff.nffw
2) Then try the PCI name:
pci-0000:04:00.0.nffw
3) Finally try the card type and media:
nic_AMDA0099-0001_2x25.nffw
Netronome's software packages install firmware files under ``/lib/firmware/netronome``
to support all the Netronome's SmartNICs and different firmware applications.
This is usually done using file names based on SmartNIC type and media and with a
directory per firmware application. Options 1 and 2 for firmware filenames allow
more than one SmartNIC, same type of SmartNIC or different ones, and to upload a
different firmware to each SmartNIC.
PF multiport support
--------------------
Some NFP cards support several physical ports with just one single PCI device.
The DPDK core is designed with a 1:1 relationship between PCI devices and DPDK
ports, so NFP PMD PF support requires handling the multiport case specifically.
During NFP PF initialization, the PMD will extract the information about the
number of PF ports from the firmware and will create as many DPDK ports as
needed.
Because the unusual relationship between a single PCI device and several DPDK
ports, there are some limitations when using more than one PF DPDK port: there
is no support for RX interrupts and it is not possible either to use those PF
ports with the device hotplug functionality.
PF multiprocess support
-----------------------
Due to how the driver needs to access the NFP through a CPP interface, which implies
to use specific registers inside the chip, the number of secondary processes with PF
ports is limited to only one.
This limitation will be solved in future versions but having basic multiprocess support
is important for allowing development and debugging through the PF using a secondary
process which will create a CPP bridge for user space tools accessing the NFP.
System configuration
--------------------
#. **Enable SR-IOV on the NFP device:** The current NFP PMD supports the PF and
the VFs on a NFP device. However, it is not possible to work with both at the
same time because the VFs require the PF being bound to the NFP PF Linux
netdev driver. Make sure you are working with a kernel with NFP PF support or
get the drivers from the above Github repository and follow the instructions
for building and installing it.
VFs need to be enabled before they can be used with the PMD.
Before enabling the VFs it is useful to obtain information about the
current NFP PCI device detected by the system:
.. code-block:: console
lspci -d19ee:
Now, for example, configure two virtual functions on a NFP-6xxx device
whose PCI system identity is "0000:03:00.0":
.. code-block:: console
echo 2 > /sys/bus/pci/devices/0000:03:00.0/sriov_numvfs
The result of this command may be shown using lspci again:
.. code-block:: console
lspci -d19ee: -k
Two new PCI devices should appear in the output of the above command. The
-k option shows the device driver, if any, that devices are bound to.
Depending on the modules loaded at this point the new PCI devices may be