summaryrefslogtreecommitdiffstats
path: root/ansible_collections/wti/remote/docs/cpm_time_config.rst
blob: 1194df078a0cacd564acbb7f628ae62da5f02ca3 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
.. _cpm_time_config_module:


cpm_time_config -- Set Time/Date parameters in WTI OOB and PDU devices.
=======================================================================

.. contents::
   :local:
   :depth: 1


Synopsis
--------

Set Time/Date and NTP parameters parameters in WTI OOB and PDU devices






Parameters
----------

  cpm_url (True, str, None)
    This is the URL of the WTI device to send the module.


  cpm_username (True, str, None)
    This is the Username of the WTI device to send the module.


  cpm_password (True, str, None)
    This is the Password of the WTI device to send the module.


  use_https (False, bool, True)
    Designates to use an https connection or http connection.


  validate_certs (False, bool, True)
    If false, SSL certificates will not be validated. This should only be used

    on personally controlled sites using self-signed certificates.


  use_proxy (False, bool, False)
    Flag to control if the lookup will observe HTTP proxy environment variables when present.


  date (False, str, None)
    Static date in the format of two digit month, two digit day, four digit year separated by a slash symbol.


  time (False, str, None)
    Static time in the format of two digit hour, two digit minute, two digit second separated by a colon symbol.


  timezone (False, int, None)
    This is timezone that is assigned to the WTI device.


  ntpenable (False, int, None)
    This enables or disables the NTP client service.


  ipv4address (False, str, None)
    Comma separated string of up to two addresses for a primary and secondary IPv4 base NTP server.


  ipv6address (False, str, None)
    Comma separated string of up to two addresses for a primary and secondary IPv6 base NTP server.


  timeout (False, int, None)
    Set the network timeout in seconds of contacting the NTP servers, valid options can be from 1-60.





Notes
-----

.. note::
   - Use ``groups/cpm`` in ``module_defaults`` to set common options used between CPM modules.




Examples
--------

.. code-block:: yaml+jinja

    
    # Set a static time/date and timezone of a WTI device
    - name: Set known fixed time/date of a WTI device
      cpm_time_config:
        cpm_url: "nonexist.wti.com"
        cpm_username: "super"
        cpm_password: "super"
        use_https: true
        validate_certs: false
        date: "12/12/2019"
        time: "09:23:46"
        timezone: 5

    # Enable NTP and set primary and seconday servers of a WTI device
    - name: Set NTP primary and seconday servers of a WTI device
      cpm_time_config:
        cpm_url: "nonexist.wti.com"
        cpm_username: "super"
        cpm_password: "super"
        use_https: true
        validate_certs: false
        timezone: 5
        ntpenable: 1
        ipv4address: "129.6.15.28.pool.ntp.org"
        timeout: 15



Return Values
-------------

data (always, complex, )
  The output JSON returned from the commands sent


  date (success, str, 11/14/2019)
    Current Date of the WTI device after module execution.


  time (success, str, 12:12:00)
    Current Time of the WTI device after module execution.


  timezone (success, int, 5)
    Current Timezone of the WTI device after module execution.


  ntp (always, dict, {'enable': '0', 'ietf-ipv4': {'address': [{'primary': '192.168.0.169', 'secondary': '12.34.56.78'}]}, 'ietf-ipv6': {'address': [{'primary': '', 'secondary': ''}]}, 'timeout': '4'})
    Current k/v pairs of ntp info of the WTI device after module execution.






Status
------




- This module is not guaranteed to have a backwards compatible interface. *[preview]*


- This module is maintained by community.



Authors
~~~~~~~