summaryrefslogtreecommitdiffstats
path: root/agents/autodetect/fence_lpar.py
blob: 6676e1c656578c20eeee8655edfa519c2d66f5fe (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
#!/usr/bin/python -tt

#####
##
## The Following Agent Has Been Tested On:
##
##  Version
## +---------------------------------------------+
##  Tested on HMC
##
#####

import sys, re
import atexit
sys.path.append("@FENCEAGENTSLIBDIR@")
from fencing import *
from fencing import fail, fail_usage, EC_STATUS_HMC

#BEGIN_VERSION_GENERATION
RELEASE_VERSION=""
REDHAT_COPYRIGHT=""
BUILD_DATE=""
#END_VERSION_GENERATION

def get_power_status(conn, options):
	if options["--hmc-version"] == "3":
		conn.send("lssyscfg -r lpar -m " + options["--managed"] + " -n " + options["--plug"] + " -F name,state\n")
		conn.log_expect(options["--command-prompt"], int(options["--power-timeout"]))

		try:
			status = re.compile("^" + options["--plug"] + ",(.*?),.*$",
					re.IGNORECASE | re.MULTILINE).search(conn.before).group(1)
		except AttributeError:
			fail(EC_STATUS_HMC)
	elif options["--hmc-version"] == "4":
		conn.send("lssyscfg -r lpar -m "+ options["--managed"] +
				" --filter 'lpar_names=" + options["--plug"] + "'\n")
		conn.log_expect(options["--command-prompt"], int(options["--power-timeout"]))

		try:
			status = re.compile(",state=(.*?),", re.IGNORECASE).search(conn.before).group(1)
		except AttributeError:
			fail(EC_STATUS_HMC)

	##
	## Transformation to standard ON/OFF status if possible
	if status in ["Running", "Open Firmware", "Shutting Down", "Starting"]:
		status = "on"
	else:
		status = "off"

	return status

def set_power_status(conn, options):
	if options["--hmc-version"] == "3":
		conn.send("chsysstate -o " + options["--action"] + " -r lpar -m " + options["--managed"]
			+ " -n " + options["--plug"] + "\n")
		conn.log_expect(options["--command-prompt"], int(options["--power-timeout"]))
	elif options["--hmc-version"] == "4":
		if options["--action"] == "on":
			conn.send("chsysstate -o on -r lpar -m " + options["--managed"] +
				" -n " + options["--plug"] +
				" -f `lssyscfg -r lpar -F curr_profile " +
				" -m " + options["--managed"] +
				" --filter \"lpar_names=" + options["--plug"] + "\"`\n")
		else:
			conn.send("chsysstate -o shutdown -r lpar --immed" +
				" -m " + options["--managed"] + " -n " + options["--plug"] + "\n")
		conn.log_expect(options["--command-prompt"], int(options["--power-timeout"]))

def get_lpar_list(conn, options):
	outlets = {}
	if options["--hmc-version"] == "3":
		conn.send("query_partition_names -m " + options["--managed"] + "\n")
		conn.log_expect(options["--command-prompt"], int(options["--power-timeout"]))

		## We have to remove first 3 lines (command + header) and last line (part of new prompt)
		####
		res = re.search("^.+?\n(.+?\n){2}(.*)\n.*$", conn.before, re.S)

		if res == None:
			fail_usage("Unable to parse output of list command")

		lines = res.group(2).split("\n")
		for outlet_line in lines:
			outlets[outlet_line.rstrip()] = ("", "")
	elif options["--hmc-version"] == "4":
		conn.send("lssyscfg -r lpar -m " + options["--managed"] +
			" -F name:state\n")
		conn.log_expect(options["--command-prompt"], int(options["--power-timeout"]))

		## We have to remove first line (command) and last line (part of new prompt)
		####
		res = re.search("^.+?\n(.*)\n.*$", conn.before, re.S)

		if res == None:
			fail_usage("Unable to parse output of list command")

		lines = res.group(1).split("\n")
		for outlet_line in lines:
			(port, status) = outlet_line.split(":")
			outlets[port] = ("", status)

	return outlets

def define_new_opts():
	all_opt["managed"] = {
		"getopt" : "s:",
		"longopt" : "managed",
		"help" : "-s, --managed=[id]             Name of the managed system",
		"required" : "0",
		"shortdesc" : "Managed system name",
		"order" : 1}
	all_opt["hmc_version"] = {
		"getopt" : "H:",
		"longopt" : "hmc-version",
		"help" : "-H, --hmc-version=[version]    Force HMC version to use: (3|4) (default: 4)",
		"required" : "0",
		"shortdesc" : "Force HMC version to use",
		"default" : "4",
		"choices" : ["3", "4"],
		"order" : 1}

def main():
	device_opt = ["ipaddr", "login", "passwd", "secure", "cmd_prompt", \
	                "port", "managed", "hmc_version"]

	atexit.register(atexit_handler)

	define_new_opts()

	all_opt["login_timeout"]["default"] = "15"
	all_opt["secure"]["default"] = "1"
	all_opt["cmd_prompt"]["default"] = [r":~>", r"]\$", r"\$ "]

	options = check_input(device_opt, process_input(device_opt), other_conditions = True)

	docs = {}
	docs["shortdesc"] = "Fence agent for IBM LPAR"
	docs["longdesc"] = ""
	docs["vendorurl"] = "http://www.ibm.com"
	show_docs(options, docs)

	if not options.has_key("--managed"):
		fail_usage("Failed: You have to enter name of managed system")

	if options["--action"] == "validate-all":
		sys.exit(0)

	##
	## Operate the fencing device
	####
	conn = fence_login(options)
	result = fence_action(conn, options, set_power_status, get_power_status, get_lpar_list)
	fence_logout(conn, "quit\r\n")
	sys.exit(result)

if __name__ == "__main__":