summaryrefslogtreecommitdiffstats
path: root/doc/man/nvme_smart_crit.2
blob: 76c2d79b9f5ea56793307b7d35903b2e2bfb0b56 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
.TH "libnvme" 9 "enum nvme_smart_crit" "May 2024" "API Manual" LINUX
.SH NAME
enum nvme_smart_crit \- Critical Warning
.SH SYNOPSIS
enum nvme_smart_crit {
.br
.BI "    NVME_SMART_CRIT_SPARE"
, 
.br
.br
.BI "    NVME_SMART_CRIT_TEMPERATURE"
, 
.br
.br
.BI "    NVME_SMART_CRIT_DEGRADED"
, 
.br
.br
.BI "    NVME_SMART_CRIT_MEDIA"
, 
.br
.br
.BI "    NVME_SMART_CRIT_VOLATILE_MEMORY"
, 
.br
.br
.BI "    NVME_SMART_CRIT_PMR_RO"

};
.SH Constants
.IP "NVME_SMART_CRIT_SPARE" 12
If set, then the available spare capacity has fallen
below the threshold.
.IP "NVME_SMART_CRIT_TEMPERATURE" 12
If set, then a temperature is either greater
than or equal to an over temperature threshold; or
less than or equal to an under temperature threshold.
.IP "NVME_SMART_CRIT_DEGRADED" 12
If set, then the NVM subsystem reliability has
been degraded due to significant media related errors
or any internal error that degrades NVM subsystem
reliability.
.IP "NVME_SMART_CRIT_MEDIA" 12
If set, then all of the media has been placed in read
only mode. The controller shall not set this bit if
the read-only condition on the media is a result of
a change in the write protection state of a namespace.
.IP "NVME_SMART_CRIT_VOLATILE_MEMORY" 12
If set, then the volatile memory backup
device has failed. This field is only valid if the
controller has a volatile memory backup solution.
.IP "NVME_SMART_CRIT_PMR_RO" 12
If set, then the Persistent Memory Region has become
read-only or unreliable.