summaryrefslogtreecommitdiffstats
path: root/Documentation/devicetree/bindings/iio/temperature/melexis,mlx90632.yaml
diff options
context:
space:
mode:
authorDaniel Baumann <daniel.baumann@progress-linux.org>2024-05-18 18:50:12 +0000
committerDaniel Baumann <daniel.baumann@progress-linux.org>2024-05-18 18:50:12 +0000
commit8665bd53f2f2e27e5511d90428cb3f60e6d0ce15 (patch)
tree8d58900dc0ebd4a3011f92c128d2fe45bc7c4bf2 /Documentation/devicetree/bindings/iio/temperature/melexis,mlx90632.yaml
parentAdding debian version 6.7.12-1. (diff)
downloadlinux-8665bd53f2f2e27e5511d90428cb3f60e6d0ce15.tar.xz
linux-8665bd53f2f2e27e5511d90428cb3f60e6d0ce15.zip
Merging upstream version 6.8.9.
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'Documentation/devicetree/bindings/iio/temperature/melexis,mlx90632.yaml')
-rw-r--r--Documentation/devicetree/bindings/iio/temperature/melexis,mlx90632.yaml19
1 files changed, 17 insertions, 2 deletions
diff --git a/Documentation/devicetree/bindings/iio/temperature/melexis,mlx90632.yaml b/Documentation/devicetree/bindings/iio/temperature/melexis,mlx90632.yaml
index 4a55e7f25a..03bb5d4fa8 100644
--- a/Documentation/devicetree/bindings/iio/temperature/melexis,mlx90632.yaml
+++ b/Documentation/devicetree/bindings/iio/temperature/melexis,mlx90632.yaml
@@ -4,7 +4,7 @@
$id: http://devicetree.org/schemas/iio/temperature/melexis,mlx90632.yaml#
$schema: http://devicetree.org/meta-schemas/core.yaml#
-title: Melexis MLX90632 contactless Infra Red temperature sensor
+title: Melexis MLX90632 and MLX90635 contactless Infra Red temperature sensor
maintainers:
- Crt Mori <cmo@melexis.com>
@@ -27,9 +27,24 @@ description: |
Since measured object emissivity effects Infra Red energy emitted,
emissivity should be set before requesting the object temperature.
+ https://www.melexis.com/en/documents/documentation/datasheets/datasheet-mlx90635
+
+ MLX90635 is most suitable for consumer applications where
+ measured object temperature is in range between -20 to 100 degrees
+ Celsius with relative error of measurement 2 degree Celsius in
+ object temperature range for industrial applications, while just 0.2
+ degree Celsius for human body measurement applications. Since it can
+ operate and measure ambient temperature in range of -20 to 85 degrees
+ Celsius it is suitable also for outdoor use.
+
+ Since measured object emissivity effects Infra Red energy emitted,
+ emissivity should be set before requesting the object temperature.
+
properties:
compatible:
- const: melexis,mlx90632
+ enum:
+ - melexis,mlx90632
+ - melexis,mlx90635
reg:
maxItems: 1