summaryrefslogtreecommitdiffstats
path: root/tools/perf/pmu-events/arch/x86/skylake/floating-point.json
diff options
context:
space:
mode:
authorDaniel Baumann <daniel.baumann@progress-linux.org>2024-04-11 08:27:49 +0000
committerDaniel Baumann <daniel.baumann@progress-linux.org>2024-04-11 08:27:49 +0000
commitace9429bb58fd418f0c81d4c2835699bddf6bde6 (patch)
treeb2d64bc10158fdd5497876388cd68142ca374ed3 /tools/perf/pmu-events/arch/x86/skylake/floating-point.json
parentInitial commit. (diff)
downloadlinux-ace9429bb58fd418f0c81d4c2835699bddf6bde6.tar.xz
linux-ace9429bb58fd418f0c81d4c2835699bddf6bde6.zip
Adding upstream version 6.6.15.upstream/6.6.15
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'tools/perf/pmu-events/arch/x86/skylake/floating-point.json')
-rw-r--r--tools/perf/pmu-events/arch/x86/skylake/floating-point.json82
1 files changed, 82 insertions, 0 deletions
diff --git a/tools/perf/pmu-events/arch/x86/skylake/floating-point.json b/tools/perf/pmu-events/arch/x86/skylake/floating-point.json
new file mode 100644
index 0000000000..5891bd74af
--- /dev/null
+++ b/tools/perf/pmu-events/arch/x86/skylake/floating-point.json
@@ -0,0 +1,82 @@
+[
+ {
+ "BriefDescription": "Counts once for most SIMD 128-bit packed computational double precision floating-point instructions retired. Counts twice for DPP and FM(N)ADD/SUB instructions retired.",
+ "EventCode": "0xC7",
+ "EventName": "FP_ARITH_INST_RETIRED.128B_PACKED_DOUBLE",
+ "PublicDescription": "Counts once for most SIMD 128-bit packed computational double precision floating-point instructions retired; some instructions will count twice as noted below. Each count represents 2 computation operations, one for each element. Applies to packed double precision floating-point instructions: ADD SUB HADD HSUB SUBADD MUL DIV MIN MAX SQRT DPP FM(N)ADD/SUB. DPP and FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.",
+ "SampleAfterValue": "2000003",
+ "UMask": "0x4"
+ },
+ {
+ "BriefDescription": "Counts once for most SIMD 128-bit packed computational single precision floating-point instruction retired. Counts twice for DPP and FM(N)ADD/SUB instructions retired.",
+ "EventCode": "0xC7",
+ "EventName": "FP_ARITH_INST_RETIRED.128B_PACKED_SINGLE",
+ "PublicDescription": "Counts once for most SIMD 128-bit packed computational single precision floating-point instructions retired; some instructions will count twice as noted below. Each count represents 4 computation operations, one for each element. Applies to packed single precision floating-point instructions: ADD SUB HADD HSUB SUBADD MUL DIV MIN MAX SQRT RSQRT RCP DPP FM(N)ADD/SUB. DPP and FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.",
+ "SampleAfterValue": "2000003",
+ "UMask": "0x8"
+ },
+ {
+ "BriefDescription": "Counts once for most SIMD 256-bit packed double computational precision floating-point instructions retired. Counts twice for DPP and FM(N)ADD/SUB instructions retired.",
+ "EventCode": "0xC7",
+ "EventName": "FP_ARITH_INST_RETIRED.256B_PACKED_DOUBLE",
+ "PublicDescription": "Counts once for most SIMD 256-bit packed double computational precision floating-point instructions retired; some instructions will count twice as noted below. Each count represents 4 computation operations, one for each element. Applies to packed double precision floating-point instructions: ADD SUB HADD HSUB SUBADD MUL DIV MIN MAX SQRT FM(N)ADD/SUB. FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.",
+ "SampleAfterValue": "2000003",
+ "UMask": "0x10"
+ },
+ {
+ "BriefDescription": "Counts once for most SIMD 256-bit packed single computational precision floating-point instructions retired. Counts twice for DPP and FM(N)ADD/SUB instructions retired.",
+ "EventCode": "0xC7",
+ "EventName": "FP_ARITH_INST_RETIRED.256B_PACKED_SINGLE",
+ "PublicDescription": "Counts once for most SIMD 256-bit packed single computational precision floating-point instructions retired; some instructions will count twice as noted below. Each count represents 8 computation operations, one for each element. Applies to packed single precision floating-point instructions: ADD SUB HADD HSUB SUBADD MUL DIV MIN MAX SQRT RSQRT RCP DPP FM(N)ADD/SUB. DPP and FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.",
+ "SampleAfterValue": "2000003",
+ "UMask": "0x20"
+ },
+ {
+ "BriefDescription": "Number of SSE/AVX computational 128-bit packed single and 256-bit packed double precision FP instructions retired; some instructions will count twice as noted below. Each count represents 2 or/and 4 computation operations, 1 for each element. Applies to SSE* and AVX* packed single precision and packed double precision FP instructions: ADD SUB HADD HSUB SUBADD MUL DIV MIN MAX RCP14 RSQRT14 SQRT DPP FM(N)ADD/SUB. DPP and FM(N)ADD/SUB count twice as they perform 2 calculations per element.",
+ "EventCode": "0xC7",
+ "EventName": "FP_ARITH_INST_RETIRED.4_FLOPS",
+ "PublicDescription": "Number of SSE/AVX computational 128-bit packed single precision and 256-bit packed double precision floating-point instructions retired; some instructions will count twice as noted below. Each count represents 2 or/and 4 computation operations, one for each element. Applies to SSE* and AVX* packed single precision floating-point and packed double precision floating-point instructions: ADD SUB HADD HSUB SUBADD MUL DIV MIN MAX RCP14 RSQRT14 SQRT DPP FM(N)ADD/SUB. DPP and FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.",
+ "SampleAfterValue": "1000003",
+ "UMask": "0x18"
+ },
+ {
+ "BriefDescription": "Counts once for most SIMD scalar computational floating-point instructions retired. Counts twice for DPP and FM(N)ADD/SUB instructions retired.",
+ "EventCode": "0xC7",
+ "EventName": "FP_ARITH_INST_RETIRED.SCALAR",
+ "PublicDescription": "Counts once for most SIMD scalar computational single precision and double precision floating-point instructions retired; some instructions will count twice as noted below. Each count represents 1 computational operation. Applies to SIMD scalar single precision floating-point instructions: ADD SUB MUL DIV MIN MAX SQRT RSQRT RCP FM(N)ADD/SUB. FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.",
+ "SampleAfterValue": "2000003",
+ "UMask": "0x3"
+ },
+ {
+ "BriefDescription": "Counts once for most SIMD scalar computational double precision floating-point instructions retired. Counts twice for DPP and FM(N)ADD/SUB instructions retired.",
+ "EventCode": "0xC7",
+ "EventName": "FP_ARITH_INST_RETIRED.SCALAR_DOUBLE",
+ "PublicDescription": "Counts once for most SIMD scalar computational double precision floating-point instructions retired; some instructions will count twice as noted below. Each count represents 1 computational operation. Applies to SIMD scalar double precision floating-point instructions: ADD SUB MUL DIV MIN MAX SQRT FM(N)ADD/SUB. FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.",
+ "SampleAfterValue": "2000003",
+ "UMask": "0x1"
+ },
+ {
+ "BriefDescription": "Counts once for most SIMD scalar computational single precision floating-point instructions retired. Counts twice for DPP and FM(N)ADD/SUB instructions retired.",
+ "EventCode": "0xC7",
+ "EventName": "FP_ARITH_INST_RETIRED.SCALAR_SINGLE",
+ "PublicDescription": "Counts once for most SIMD scalar computational single precision floating-point instructions retired; some instructions will count twice as noted below. Each count represents 1 computational operation. Applies to SIMD scalar single precision floating-point instructions: ADD SUB MUL DIV MIN MAX SQRT RSQRT RCP FM(N)ADD/SUB. FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.",
+ "SampleAfterValue": "2000003",
+ "UMask": "0x2"
+ },
+ {
+ "BriefDescription": "Number of any Vector retired FP arithmetic instructions",
+ "EventCode": "0xC7",
+ "EventName": "FP_ARITH_INST_RETIRED.VECTOR",
+ "SampleAfterValue": "2000003",
+ "UMask": "0xfc"
+ },
+ {
+ "BriefDescription": "Cycles with any input/output SSE or FP assist",
+ "CounterMask": "1",
+ "EventCode": "0xCA",
+ "EventName": "FP_ASSIST.ANY",
+ "PublicDescription": "Counts cycles with any input and output SSE or x87 FP assist. If an input and output assist are detected on the same cycle the event increments by 1.",
+ "SampleAfterValue": "100003",
+ "UMask": "0x1e"
+ }
+]