+.. SPDX-License-Identifier: GPL-2.0-or-later
+
+Kernel driver ChipCap2
+======================
+
+Supported chips:
+
+ * Amphenol CC2D23, CC2D23S, CC2D25, CC2D25S, CC2D33, CC2D33S, CC2D35, CC2D35S
+
+ Prefix: 'chipcap2'
+
+ Addresses scanned: -
+
+ Datasheet: https://www.amphenol-sensors.com/en/telaire/humidity/527-humidity-sensors/3095-chipcap-2
+
+Author:
+
+ - Javier Carrasco <javier.carrasco.cruz@gmail.com>
+
+Description
+-----------
+
+This driver implements support for the Amphenol ChipCap 2, a humidity and
+temperature chip family. Temperature is measured in milli degrees celsius,
+relative humidity is expressed as a per cent mille. The measurement ranges
+are the following:
+
+ - Relative humidity: 0 to 100000 pcm (14-bit resolution)
+ - Temperature: -40000 to +125000 m°C (14-bit resolution)
+
+The device communicates with the I2C protocol and uses the I2C address 0x28
+by default.
+
+Depending on the hardware configuration, up to two humidity alarms to control
+minimum and maximum values are provided. Their thresholds and hystersis can be
+configured via sysfs.
+
+Thresholds and hysteris must be provided as a per cent mille. These values
+might be truncated to match the 14-bit device resolution (6.1 pcm/LSB)
+
+Known Issues
+------------
+
+The driver does not support I2C address and command window length modification.
+
+sysfs-Interface
+---------------
+
+The following list includes the sysfs attributes that the driver always provides,
+their permissions and a short description:
+
+=============================== ======= ========================================
+Name Perm Description
+=============================== ======= ========================================
+temp1_input: RO temperature input
+humidity1_input: RO humidity input
+=============================== ======= ========================================
+
+The following list includes the sysfs attributes that the driver may provide
+depending on the hardware configuration:
+
+=============================== ======= ========================================
+Name Perm Description
+=============================== ======= ========================================
+humidity1_min: RW humidity low limit. Measurements under
+ this limit trigger a humidity low alarm
+humidity1_max: RW humidity high limit. Measurements above
+ this limit trigger a humidity high alarm
+humidity1_min_hyst: RW humidity low hystersis
+humidity1_max_hyst: RW humidity high hystersis
+humidity1_min_alarm: RO humidity low alarm indicator
+humidity1_max_alarm: RO humidity high alarm indicator
+=============================== ======= ========================================