summaryrefslogtreecommitdiffstats
path: root/Documentation/hwmon/ntc_thermistor.rst
blob: d0e7f91726b9c42f1eb2afa999c6ee8181c64dd1 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
Kernel driver ntc_thermistor
============================

Supported thermistors from Murata:

* Murata NTC Thermistors NCP15WB473, NCP18WB473, NCP21WB473, NCP03WB473,
  NCP15WL333, NCP03WF104, NCP15XH103

  Prefixes: 'ncp15wb473', 'ncp18wb473', 'ncp21wb473', 'ncp03wb473',
  'ncp15wl333', 'ncp03wf104', 'ncp15xh103'

  Datasheet: Publicly available at Murata

Supported thermistors from EPCOS:

* EPCOS NTC Thermistors B57330V2103

  Prefixes: b57330v2103

  Datasheet: Publicly available at EPCOS

Other NTC thermistors can be supported simply by adding compensation
tables; e.g., NCP15WL333 support is added by the table ncpXXwl333.

Authors:

	MyungJoo Ham <myungjoo.ham@samsung.com>

Description
-----------

The NTC (Negative Temperature Coefficient) thermistor is a simple thermistor
that requires users to provide the resistance and lookup the corresponding
compensation table to get the temperature input.

The NTC driver provides lookup tables with a linear approximation function
and four circuit models with an option not to use any of the four models.

Using the following convention::

   $	resistor
   [TH]	the thermistor

The four circuit models provided are:

1. connect = NTC_CONNECTED_POSITIVE, pullup_ohm > 0::

     [pullup_uV]
	 |    |
	[TH]  $ (pullup_ohm)
	 |    |
	 +----+-----------------------[read_uV]
	 |
	 $ (pulldown_ohm)
	 |
	-+- (ground)

2. connect = NTC_CONNECTED_POSITIVE, pullup_ohm = 0 (not-connected)::

     [pullup_uV]
	 |
	[TH]
	 |
	 +----------------------------[read_uV]
	 |
	 $ (pulldown_ohm)
	 |
	-+- (ground)

3. connect = NTC_CONNECTED_GROUND, pulldown_ohm > 0::

     [pullup_uV]
	 |
	 $ (pullup_ohm)
	 |
	 +----+-----------------------[read_uV]
	 |    |
	[TH]  $ (pulldown_ohm)
	 |    |
	-+----+- (ground)

4. connect = NTC_CONNECTED_GROUND, pulldown_ohm = 0 (not-connected)::

     [pullup_uV]
	 |
	 $ (pullup_ohm)
	 |
	 +----------------------------[read_uV]
	 |
	[TH]
	 |
	-+- (ground)

When one of the four circuit models is used, read_uV, pullup_uV, pullup_ohm,
pulldown_ohm, and connect should be provided. When none of the four models
are suitable or the user can get the resistance directly, the user should
provide read_ohm and _not_ provide the others.

Sysfs Interface
---------------

=============== == =============================================================
name		   the mandatory global attribute, the thermistor name.
=============== == =============================================================
temp1_type	RO always 4 (thermistor)

temp1_input	RO measure the temperature and provide the measured value.
		   (reading this file initiates the reading procedure.)
=============== == =============================================================

Note that each NTC thermistor has only _one_ thermistor; thus, only temp1 exists.