summaryrefslogtreecommitdiffstats
path: root/drivers/iio/pressure/rohm-bm1390.c
blob: ccaa07a569c9a8a07c6965ef0cf4ba4a734a42ee (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
// SPDX-License-Identifier: GPL-2.0-only
/*
 * BM1390 ROHM pressure sensor
 *
 * Copyright (c) 2023, ROHM Semiconductor.
 * https://fscdn.rohm.com/en/products/databook/datasheet/ic/sensor/pressure/bm1390glv-z-e.pdf
 */

#include <linux/bitfield.h>
#include <linux/bits.h>
#include <linux/device.h>
#include <linux/i2c.h>
#include <linux/module.h>
#include <linux/regmap.h>
#include <linux/regulator/consumer.h>

#include <linux/iio/iio.h>
#include <linux/iio/trigger.h>
#include <linux/iio/trigger_consumer.h>
#include <linux/iio/triggered_buffer.h>

#define BM1390_REG_MANUFACT_ID		0x0f
#define BM1390_REG_PART_ID		0x10
#define BM1390_REG_POWER		0x12
#define BM1390_MASK_POWER		BIT(0)
#define BM1390_POWER_ON			BM1390_MASK_POWER
#define BM1390_POWER_OFF		0x00
#define BM1390_REG_RESET		0x13
#define BM1390_MASK_RESET		BIT(0)
#define BM1390_RESET_RELEASE		BM1390_MASK_RESET
#define BM1390_RESET			0x00
#define BM1390_REG_MODE_CTRL		0x14
#define BM1390_MASK_MEAS_MODE		GENMASK(1, 0)
#define BM1390_MASK_DRDY_EN		BIT(4)
#define BM1390_MASK_WMI_EN		BIT(2)
#define BM1390_MASK_AVE_NUM		GENMASK(7, 5)

/*
 * Data-sheet states that when the IIR is used, the AVE_NUM must be set to
 * value 110b
 */
#define BM1390_IIR_AVE_NUM		0x06
#define BM1390_REG_FIFO_CTRL		0x15
#define BM1390_MASK_IIR_MODE		GENMASK(1, 0)
#define BM1390_IIR_MODE_OFF		0x0
#define BM1390_IIR_MODE_WEAK		0x1
#define BM1390_IIR_MODE_MID		0x2
#define BM1390_IIR_MODE_STRONG		0x3

#define BM1390_MASK_FIFO_LEN		BIT(6)
#define BM1390_MASK_FIFO_EN		BIT(7)
#define BM1390_WMI_MIN			2
#define BM1390_WMI_MAX			3

#define BM1390_REG_FIFO_LVL		0x18
#define BM1390_MASK_FIFO_LVL		GENMASK(2, 0)
#define BM1390_REG_STATUS		0x19
#define BM1390_REG_PRESSURE_BASE	0x1a
#define BM1390_REG_TEMP_HI		0x1d
#define BM1390_REG_TEMP_LO		0x1e
#define BM1390_MAX_REGISTER		BM1390_REG_TEMP_LO

#define BM1390_ID			0x34

/* Regmap configs */
static const struct regmap_range bm1390_volatile_ranges[] = {
	{
		.range_min = BM1390_REG_STATUS,
		.range_max = BM1390_REG_STATUS,
	},
	{
		.range_min = BM1390_REG_FIFO_LVL,
		.range_max = BM1390_REG_TEMP_LO,
	},
};

static const struct regmap_access_table bm1390_volatile_regs = {
	.yes_ranges = &bm1390_volatile_ranges[0],
	.n_yes_ranges = ARRAY_SIZE(bm1390_volatile_ranges),
};

static const struct regmap_range bm1390_precious_ranges[] = {
	{
		.range_min = BM1390_REG_STATUS,
		.range_max = BM1390_REG_STATUS,
	},
};

static const struct regmap_access_table bm1390_precious_regs = {
	.yes_ranges = &bm1390_precious_ranges[0],
	.n_yes_ranges = ARRAY_SIZE(bm1390_precious_ranges),
};

static const struct regmap_range bm1390_read_only_ranges[] = {
	{
		.range_min = BM1390_REG_MANUFACT_ID,
		.range_max = BM1390_REG_PART_ID,
	}, {
		.range_min = BM1390_REG_FIFO_LVL,
		.range_max = BM1390_REG_TEMP_LO,
	},
};

static const struct regmap_access_table bm1390_ro_regs = {
	.no_ranges = &bm1390_read_only_ranges[0],
	.n_no_ranges = ARRAY_SIZE(bm1390_read_only_ranges),
};

static const struct regmap_range bm1390_noinc_read_ranges[] = {
	{
		.range_min = BM1390_REG_PRESSURE_BASE,
		.range_max = BM1390_REG_TEMP_LO,
	},
};

static const struct regmap_access_table bm1390_nir_regs = {
	.yes_ranges = &bm1390_noinc_read_ranges[0],
	.n_yes_ranges = ARRAY_SIZE(bm1390_noinc_read_ranges),
};

static const struct regmap_config bm1390_regmap = {
	.reg_bits = 8,
	.val_bits = 8,
	.volatile_table = &bm1390_volatile_regs,
	.wr_table = &bm1390_ro_regs,
	.rd_noinc_table = &bm1390_nir_regs,
	.precious_table = &bm1390_precious_regs,
	.max_register = BM1390_MAX_REGISTER,
	.cache_type = REGCACHE_RBTREE,
	.disable_locking = true,
};

enum {
	BM1390_STATE_SAMPLE,
	BM1390_STATE_FIFO,
};

struct bm1390_data_buf {
	u32 pressure;
	__be16 temp;
	s64 ts __aligned(8);
};

/* BM1390 has FIFO for 4 pressure samples */
#define BM1390_FIFO_LENGTH	4

struct bm1390_data {
	s64 timestamp, old_timestamp;
	struct iio_trigger *trig;
	struct regmap *regmap;
	struct device *dev;
	struct bm1390_data_buf buf;
	int irq;
	unsigned int state;
	bool trigger_enabled;
	u8 watermark;

	/* Prevent accessing sensor during FIFO read sequence */
	struct mutex mutex;
};

enum {
	BM1390_CHAN_PRESSURE,
	BM1390_CHAN_TEMP,
};

static const struct iio_chan_spec bm1390_channels[] = {
	{
		.type = IIO_PRESSURE,
		.info_mask_separate = BIT(IIO_CHAN_INFO_RAW),
		/*
		 * When IIR is used, we must fix amount of averaged samples.
		 * Thus we don't allow setting oversampling ratio.
		 */
		.info_mask_shared_by_type = BIT(IIO_CHAN_INFO_SCALE),
		.scan_index = BM1390_CHAN_PRESSURE,
		.scan_type = {
			.sign = 'u',
			.realbits = 22,
			.storagebits = 32,
			.endianness = IIO_LE,
		},
	},
	{
		.type = IIO_TEMP,
		.info_mask_separate = BIT(IIO_CHAN_INFO_RAW),
		.info_mask_shared_by_type = BIT(IIO_CHAN_INFO_SCALE),
		.scan_index = BM1390_CHAN_TEMP,
		.scan_type = {
			.sign = 's',
			.realbits = 16,
			.storagebits = 16,
			.endianness = IIO_BE,
		},
	},
	IIO_CHAN_SOFT_TIMESTAMP(2),
};

/*
 * We can't skip reading the pressure because the watermark IRQ is acked
 * only when the pressure data is read from the FIFO.
 */
static const unsigned long bm1390_scan_masks[] = {
	BIT(BM1390_CHAN_PRESSURE),
	BIT(BM1390_CHAN_PRESSURE) | BIT(BM1390_CHAN_TEMP),
	0
};

static int bm1390_read_temp(struct bm1390_data *data, int *temp)
{
	__be16 temp_raw;
	int ret;

	ret = regmap_bulk_read(data->regmap, BM1390_REG_TEMP_HI, &temp_raw,
			       sizeof(temp_raw));
	if (ret)
		return ret;

	*temp = be16_to_cpu(temp_raw);

	return 0;
}

static int bm1390_pressure_read(struct bm1390_data *data, u32 *pressure)
{
	/* Pressure data is in 3 8-bit registers */
	u8 raw[3];
	int ret;

	ret = regmap_bulk_read(data->regmap, BM1390_REG_PRESSURE_BASE,
			       raw, sizeof(raw));
	if (ret < 0)
		return ret;

	*pressure = (u32)(raw[2] >> 2 | raw[1] << 6 | raw[0] << 14);

	return 0;
}

 /* The enum values map directly to register bits */
enum bm1390_meas_mode {
	BM1390_MEAS_MODE_STOP = 0x0,
	BM1390_MEAS_MODE_1SHOT = 0x1,
	BM1390_MEAS_MODE_CONTINUOUS = 0x2,
};

static int bm1390_meas_set(struct bm1390_data *data, enum bm1390_meas_mode mode)
{
	return regmap_update_bits(data->regmap, BM1390_REG_MODE_CTRL,
				  BM1390_MASK_MEAS_MODE, mode);
}

/*
 * If the trigger is not used we just wait until the measurement has
 * completed. The data-sheet says maximum measurement cycle (regardless
 * the AVE_NUM) is 200 mS so let's just sleep at least that long. If speed
 * is needed the trigger should be used.
 */
#define BM1390_MAX_MEAS_TIME_MS 205

static int bm1390_read_data(struct bm1390_data *data,
			struct iio_chan_spec const *chan, int *val, int *val2)
{
	int ret, warn;

	mutex_lock(&data->mutex);
	/*
	 * We use 'continuous mode' even for raw read because according to the
	 * data-sheet an one-shot mode can't be used with IIR filter.
	 */
	ret = bm1390_meas_set(data, BM1390_MEAS_MODE_CONTINUOUS);
	if (ret)
		goto unlock_out;

	switch (chan->type) {
	case IIO_PRESSURE:
		msleep(BM1390_MAX_MEAS_TIME_MS);
		ret = bm1390_pressure_read(data, val);
		break;
	case IIO_TEMP:
		msleep(BM1390_MAX_MEAS_TIME_MS);
		ret = bm1390_read_temp(data, val);
		break;
	default:
		ret = -EINVAL;
	}
	warn = bm1390_meas_set(data, BM1390_MEAS_MODE_STOP);
	if (warn)
		dev_warn(data->dev, "Failed to stop measurement (%d)\n", warn);
unlock_out:
	mutex_unlock(&data->mutex);

	return ret;
}

static int bm1390_read_raw(struct iio_dev *idev,
			   struct iio_chan_spec const *chan,
			   int *val, int *val2, long mask)
{
	struct bm1390_data *data = iio_priv(idev);
	int ret;

	switch (mask) {
	case IIO_CHAN_INFO_SCALE:
		if (chan->type == IIO_TEMP) {
			*val = 31;
			*val2 = 250000;

			return IIO_VAL_INT_PLUS_MICRO;
		} else if (chan->type == IIO_PRESSURE) {
			/*
			 * pressure in hPa is register value divided by 2048.
			 * This means kPa is 1/20480 times the register value,
			 */
			*val = 1;
			*val2 = 2048;

			return IIO_VAL_FRACTIONAL;
		}

		return -EINVAL;
	case IIO_CHAN_INFO_RAW:
		ret = iio_device_claim_direct_mode(idev);
		if (ret)
			return ret;

		ret = bm1390_read_data(data, chan, val, val2);
		iio_device_release_direct_mode(idev);
		if (ret)
			return ret;

		return IIO_VAL_INT;
	default:
		return -EINVAL;
	}
}

static int __bm1390_fifo_flush(struct iio_dev *idev, unsigned int samples,
			       s64 timestamp)
{
	/* BM1390_FIFO_LENGTH is small so we shouldn't run out of stack */
	struct bm1390_data_buf buffer[BM1390_FIFO_LENGTH];
	struct bm1390_data *data = iio_priv(idev);
	int smp_lvl, ret, i, warn, dummy;
	u64 sample_period;
	__be16 temp = 0;

	ret = regmap_read(data->regmap, BM1390_REG_FIFO_LVL, &smp_lvl);
	if (ret)
		return ret;

	smp_lvl = FIELD_GET(BM1390_MASK_FIFO_LVL, smp_lvl);
	if (!smp_lvl)
		return 0;

	if (smp_lvl > BM1390_FIFO_LENGTH) {
		/*
		 * The fifo holds maximum of 4 samples so valid values
		 * should be 0, 1, 2, 3, 4 - rest are probably bit errors
		 * in I2C line. Don't overflow if this happens.
		 */
		dev_err(data->dev, "bad FIFO level %d\n", smp_lvl);
		smp_lvl = BM1390_FIFO_LENGTH;
	}

	sample_period = timestamp - data->old_timestamp;
	do_div(sample_period, smp_lvl);

	if (samples && smp_lvl > samples)
		smp_lvl = samples;


	/*
	 * After some testing it appears that the temperature is not readable
	 * until the FIFO access has been done after the WMI. Thus, we need
	 * to read the all pressure values to memory and read the temperature
	 * only after that.
	 */
	for (i = 0; i < smp_lvl; i++) {
		/*
		 * When we start reading data from the FIFO the sensor goes to
		 * special FIFO reading mode. If any other register is accessed
		 * during the FIFO read, samples can be dropped. Prevent access
		 * until FIFO_LVL is read. We have mutex locked and we do also
		 * go performing reading of FIFO_LVL even if this read fails.
		 */
		if (test_bit(BM1390_CHAN_PRESSURE, idev->active_scan_mask)) {
			ret = bm1390_pressure_read(data, &buffer[i].pressure);
			if (ret)
				break;
		}

		/*
		 * Old timestamp is either the previous sample IRQ time,
		 * previous flush-time or, if this was first sample, the enable
		 * time. When we add a sample period to that we should get the
		 * best approximation of the time-stamp we are handling.
		 *
		 * Idea is to always keep the "old_timestamp" matching the
		 * timestamp which we are currently handling.
		 */
		data->old_timestamp += sample_period;
		buffer[i].ts = data->old_timestamp;
	}
	/* Reading the FIFO_LVL closes the FIFO access sequence */
	warn = regmap_read(data->regmap, BM1390_REG_FIFO_LVL, &dummy);
	if (warn)
		dev_warn(data->dev, "Closing FIFO sequence failed\n");

	if (ret)
		return ret;

	if (test_bit(BM1390_CHAN_TEMP, idev->active_scan_mask)) {
		ret = regmap_bulk_read(data->regmap, BM1390_REG_TEMP_HI, &temp,
				       sizeof(temp));
		if (ret)
			return ret;
	}

	if (ret)
		return ret;

	for (i = 0; i < smp_lvl; i++) {
		buffer[i].temp = temp;
		iio_push_to_buffers(idev, &buffer[i]);
	}

	return smp_lvl;
}

static int bm1390_fifo_flush(struct iio_dev *idev, unsigned int samples)
{
	struct bm1390_data *data = iio_priv(idev);
	s64 timestamp;
	int ret;

	/*
	 * If fifo_flush is being called from IRQ handler we know the stored
	 * timestamp is fairly accurate for the last stored sample. If we are
	 * called as a result of a read operation from userspace and hence
	 * before the watermark interrupt was triggered, take a timestamp
	 * now. We can fall anywhere in between two samples so the error in this
	 * case is at most one sample period.
	 * We need to have the IRQ disabled or we risk of messing-up
	 * the timestamps. If we are ran from IRQ, then the
	 * IRQF_ONESHOT has us covered - but if we are ran by the
	 * user-space read we need to disable the IRQ to be on a safe
	 * side. We do this usng synchronous disable so that if the
	 * IRQ thread is being ran on other CPU we wait for it to be
	 * finished.
	 */

	timestamp = iio_get_time_ns(idev);
	mutex_lock(&data->mutex);
	ret = __bm1390_fifo_flush(idev, samples, timestamp);
	mutex_unlock(&data->mutex);

	return ret;
}

static int bm1390_set_watermark(struct iio_dev *idev, unsigned int val)
{
	struct bm1390_data *data = iio_priv(idev);

	if (val < BM1390_WMI_MIN || val > BM1390_WMI_MAX)
		return -EINVAL;

	mutex_lock(&data->mutex);
	data->watermark = val;
	mutex_unlock(&data->mutex);

	return 0;
}

static const struct iio_info bm1390_noirq_info = {
	.read_raw = &bm1390_read_raw,
};

static const struct iio_info bm1390_info = {
	.read_raw = &bm1390_read_raw,
	.hwfifo_set_watermark = bm1390_set_watermark,
	.hwfifo_flush_to_buffer = bm1390_fifo_flush,
};

static int bm1390_chip_init(struct bm1390_data *data)
{
	int ret;

	ret = regmap_write_bits(data->regmap, BM1390_REG_POWER,
				BM1390_MASK_POWER, BM1390_POWER_ON);
	if (ret)
		return ret;

	msleep(1);

	ret = regmap_write_bits(data->regmap, BM1390_REG_RESET,
				BM1390_MASK_RESET, BM1390_RESET);
	if (ret)
		return ret;

	msleep(1);

	ret = regmap_write_bits(data->regmap, BM1390_REG_RESET,
				BM1390_MASK_RESET, BM1390_RESET_RELEASE);
	if (ret)
		return ret;

	msleep(1);

	ret = regmap_reinit_cache(data->regmap, &bm1390_regmap);
	if (ret) {
		dev_err(data->dev, "Failed to reinit reg cache\n");
		return ret;
	}

	/*
	 * Default to use IIR filter in "middle" mode. Also the AVE_NUM must
	 * be fixed when IIR is in use.
	 */
	ret = regmap_update_bits(data->regmap, BM1390_REG_MODE_CTRL,
				 BM1390_MASK_AVE_NUM, BM1390_IIR_AVE_NUM);
	if (ret)
		return ret;

	return regmap_update_bits(data->regmap, BM1390_REG_FIFO_CTRL,
				  BM1390_MASK_IIR_MODE, BM1390_IIR_MODE_MID);
}

static int bm1390_fifo_set_wmi(struct bm1390_data *data)
{
	u8 regval;

	regval = FIELD_PREP(BM1390_MASK_FIFO_LEN,
			    data->watermark - BM1390_WMI_MIN);

	return regmap_update_bits(data->regmap, BM1390_REG_FIFO_CTRL,
				  BM1390_MASK_FIFO_LEN, regval);
}

static int bm1390_fifo_enable(struct iio_dev *idev)
{
	struct bm1390_data *data = iio_priv(idev);
	int ret;

	/* We can't do buffered stuff without IRQ as we never get WMI */
	if (data->irq <= 0)
		return -EINVAL;

	mutex_lock(&data->mutex);
	if (data->trigger_enabled) {
		ret = -EBUSY;
		goto unlock_out;
	}

	/* Update watermark to HW */
	ret = bm1390_fifo_set_wmi(data);
	if (ret)
		goto unlock_out;

	/* Enable WMI_IRQ */
	ret = regmap_set_bits(data->regmap, BM1390_REG_MODE_CTRL,
			      BM1390_MASK_WMI_EN);
	if (ret)
		goto unlock_out;

	/* Enable FIFO */
	ret = regmap_set_bits(data->regmap, BM1390_REG_FIFO_CTRL,
			      BM1390_MASK_FIFO_EN);
	if (ret)
		goto unlock_out;

	data->state = BM1390_STATE_FIFO;

	data->old_timestamp = iio_get_time_ns(idev);
	ret = bm1390_meas_set(data, BM1390_MEAS_MODE_CONTINUOUS);

unlock_out:
	mutex_unlock(&data->mutex);

	return ret;
}

static int bm1390_fifo_disable(struct iio_dev *idev)
{
	struct bm1390_data *data = iio_priv(idev);
	int ret;

	msleep(1);

	mutex_lock(&data->mutex);
	ret = bm1390_meas_set(data, BM1390_MEAS_MODE_STOP);
	if (ret)
		goto unlock_out;

	/* Disable FIFO */
	ret = regmap_clear_bits(data->regmap, BM1390_REG_FIFO_CTRL,
				BM1390_MASK_FIFO_EN);
	if (ret)
		goto unlock_out;

	data->state = BM1390_STATE_SAMPLE;

	/* Disable WMI_IRQ */
	ret = regmap_clear_bits(data->regmap, BM1390_REG_MODE_CTRL,
				 BM1390_MASK_WMI_EN);

unlock_out:
	mutex_unlock(&data->mutex);

	return ret;
}

static int bm1390_buffer_postenable(struct iio_dev *idev)
{
	/*
	 * If we use data-ready trigger, then the IRQ masks should be handled by
	 * trigger enable and the hardware buffer is not used but we just update
	 * results to the IIO FIFO when data-ready triggers.
	 */
	if (iio_device_get_current_mode(idev) == INDIO_BUFFER_TRIGGERED)
		return 0;

	return bm1390_fifo_enable(idev);
}

static int bm1390_buffer_predisable(struct iio_dev *idev)
{
	if (iio_device_get_current_mode(idev) == INDIO_BUFFER_TRIGGERED)
		return 0;

	return bm1390_fifo_disable(idev);
}

static const struct iio_buffer_setup_ops bm1390_buffer_ops = {
	.postenable = bm1390_buffer_postenable,
	.predisable = bm1390_buffer_predisable,
};

static irqreturn_t bm1390_trigger_handler(int irq, void *p)
{
	struct iio_poll_func *pf = p;
	struct iio_dev *idev = pf->indio_dev;
	struct bm1390_data *data = iio_priv(idev);
	int ret, status;

	/* DRDY is acked by reading status reg */
	ret = regmap_read(data->regmap, BM1390_REG_STATUS, &status);
	if (ret || !status)
		return IRQ_NONE;

	dev_dbg(data->dev, "DRDY trig status 0x%x\n", status);

	if (test_bit(BM1390_CHAN_PRESSURE, idev->active_scan_mask)) {
		ret = bm1390_pressure_read(data, &data->buf.pressure);
		if (ret) {
			dev_warn(data->dev, "sample read failed %d\n", ret);
			return IRQ_NONE;
		}
	}

	if (test_bit(BM1390_CHAN_TEMP, idev->active_scan_mask)) {
		ret = regmap_bulk_read(data->regmap, BM1390_REG_TEMP_HI,
				       &data->buf.temp, sizeof(data->buf.temp));
		if (ret) {
			dev_warn(data->dev, "temp read failed %d\n", ret);
			return IRQ_HANDLED;
		}
	}

	iio_push_to_buffers_with_timestamp(idev, &data->buf, data->timestamp);
	iio_trigger_notify_done(idev->trig);

	return IRQ_HANDLED;
}

/* Get timestamps and wake the thread if we need to read data */
static irqreturn_t bm1390_irq_handler(int irq, void *private)
{
	struct iio_dev *idev = private;
	struct bm1390_data *data = iio_priv(idev);

	data->timestamp = iio_get_time_ns(idev);

	if (data->state == BM1390_STATE_FIFO || data->trigger_enabled)
		return IRQ_WAKE_THREAD;

	return IRQ_NONE;
}

static irqreturn_t bm1390_irq_thread_handler(int irq, void *private)
{
	struct iio_dev *idev = private;
	struct bm1390_data *data = iio_priv(idev);
	int ret = IRQ_NONE;

	mutex_lock(&data->mutex);

	if (data->trigger_enabled) {
		iio_trigger_poll_nested(data->trig);
		ret = IRQ_HANDLED;
	} else if (data->state == BM1390_STATE_FIFO) {
		int ok;

		ok = __bm1390_fifo_flush(idev, BM1390_FIFO_LENGTH,
					 data->timestamp);
		if (ok > 0)
			ret = IRQ_HANDLED;
	}

	mutex_unlock(&data->mutex);

	return ret;
}

static int bm1390_set_drdy_irq(struct bm1390_data *data, bool en)
{
	if (en)
		return regmap_set_bits(data->regmap, BM1390_REG_MODE_CTRL,
				       BM1390_MASK_DRDY_EN);
	return regmap_clear_bits(data->regmap, BM1390_REG_MODE_CTRL,
				 BM1390_MASK_DRDY_EN);
}

static int bm1390_trigger_set_state(struct iio_trigger *trig,
				    bool state)
{
	struct bm1390_data *data = iio_trigger_get_drvdata(trig);
	int ret = 0;

	mutex_lock(&data->mutex);

	if (data->trigger_enabled == state)
		goto unlock_out;

	if (data->state == BM1390_STATE_FIFO) {
		dev_warn(data->dev, "Can't set trigger when FIFO enabled\n");
		ret = -EBUSY;
		goto unlock_out;
	}

	data->trigger_enabled = state;

	if (state) {
		ret = bm1390_meas_set(data, BM1390_MEAS_MODE_CONTINUOUS);
		if (ret)
			goto unlock_out;
	} else {
		int dummy;

		ret = bm1390_meas_set(data, BM1390_MEAS_MODE_STOP);
		if (ret)
			goto unlock_out;

		/*
		 * We need to read the status register in order to ACK the
		 * data-ready which may have been generated just before we
		 * disabled the measurement.
		 */
		ret = regmap_read(data->regmap, BM1390_REG_STATUS, &dummy);
		if (ret)
			dev_warn(data->dev, "status read failed\n");
	}

	ret = bm1390_set_drdy_irq(data, state);

unlock_out:
	mutex_unlock(&data->mutex);

	return ret;
}

static const struct iio_trigger_ops bm1390_trigger_ops = {
	.set_trigger_state = bm1390_trigger_set_state,
};

static int bm1390_setup_buffer(struct bm1390_data *data, struct iio_dev *idev)
{
	int ret;

	ret = devm_iio_triggered_buffer_setup(data->dev, idev,
					      &iio_pollfunc_store_time,
					      &bm1390_trigger_handler,
					      &bm1390_buffer_ops);

	if (ret)
		return dev_err_probe(data->dev, ret,
				     "iio_triggered_buffer_setup FAIL\n");

	idev->available_scan_masks = bm1390_scan_masks;

	return 0;
}

static int bm1390_setup_trigger(struct bm1390_data *data, struct iio_dev *idev,
				int irq)
{
	struct iio_trigger *itrig;
	char *name;
	int ret;

	itrig = devm_iio_trigger_alloc(data->dev, "%sdata-rdy-dev%d", idev->name,
					    iio_device_id(idev));
	if (!itrig)
		return -ENOMEM;

	data->trig = itrig;

	itrig->ops = &bm1390_trigger_ops;
	iio_trigger_set_drvdata(itrig, data);

	name = devm_kasprintf(data->dev, GFP_KERNEL, "%s-bm1390",
			      dev_name(data->dev));
	if (name == NULL)
		return -ENOMEM;

	ret = devm_request_threaded_irq(data->dev, irq, bm1390_irq_handler,
					&bm1390_irq_thread_handler,
					IRQF_ONESHOT, name, idev);
	if (ret)
		return dev_err_probe(data->dev, ret, "Could not request IRQ\n");


	ret = devm_iio_trigger_register(data->dev, itrig);
	if (ret)
		return dev_err_probe(data->dev, ret,
				     "Trigger registration failed\n");

	return 0;
}

static int bm1390_probe(struct i2c_client *i2c)
{
	struct bm1390_data *data;
	struct regmap *regmap;
	struct iio_dev *idev;
	struct device *dev;
	unsigned int part_id;
	int ret;

	dev = &i2c->dev;

	regmap = devm_regmap_init_i2c(i2c, &bm1390_regmap);
	if (IS_ERR(regmap))
		return dev_err_probe(dev, PTR_ERR(regmap),
				     "Failed to initialize Regmap\n");

	ret = devm_regulator_get_enable(dev, "vdd");
	if (ret)
		return dev_err_probe(dev, ret, "Failed to get regulator\n");

	ret = regmap_read(regmap, BM1390_REG_PART_ID, &part_id);
	if (ret)
		return dev_err_probe(dev, ret, "Failed to access sensor\n");

	if (part_id != BM1390_ID)
		dev_warn(dev, "unknown device 0x%x\n", part_id);

	idev = devm_iio_device_alloc(dev, sizeof(*data));
	if (!idev)
		return -ENOMEM;

	data = iio_priv(idev);
	data->regmap = regmap;
	data->dev = dev;
	data->irq = i2c->irq;
	/*
	 * For now we just allow BM1390_WMI_MIN to BM1390_WMI_MAX and
	 * discard every other configuration when triggered mode is not used.
	 */
	data->watermark = BM1390_WMI_MAX;
	mutex_init(&data->mutex);

	idev->channels = bm1390_channels;
	idev->num_channels = ARRAY_SIZE(bm1390_channels);
	idev->name = "bm1390";
	idev->modes = INDIO_DIRECT_MODE;

	ret = bm1390_chip_init(data);
	if (ret)
		return dev_err_probe(dev, ret, "sensor init failed\n");

	ret = bm1390_setup_buffer(data, idev);
	if (ret)
		return ret;

	/* No trigger if we don't have IRQ for data-ready and WMI */
	if (i2c->irq > 0) {
		idev->info = &bm1390_info;
		idev->modes |= INDIO_BUFFER_SOFTWARE;
		ret = bm1390_setup_trigger(data, idev, i2c->irq);
		if (ret)
			return ret;
	} else {
		idev->info = &bm1390_noirq_info;
	}

	ret = devm_iio_device_register(dev, idev);
	if (ret < 0)
		return dev_err_probe(dev, ret,
				     "Unable to register iio device\n");

	return 0;
}

static const struct of_device_id bm1390_of_match[] = {
	{ .compatible = "rohm,bm1390glv-z" },
	{}
};
MODULE_DEVICE_TABLE(of, bm1390_of_match);

static const struct i2c_device_id bm1390_id[] = {
	{ "bm1390glv-z", },
	{}
};
MODULE_DEVICE_TABLE(i2c, bm1390_id);

static struct i2c_driver bm1390_driver = {
	.driver = {
		.name = "bm1390",
		.of_match_table = bm1390_of_match,
		/*
		 * Probing explicitly requires a few millisecond of sleep.
		 * Enabling the VDD regulator may include ramp up rates.
		 */
		.probe_type = PROBE_PREFER_ASYNCHRONOUS,
	},
	.probe = bm1390_probe,
	.id_table = bm1390_id,
};
module_i2c_driver(bm1390_driver);

MODULE_AUTHOR("Matti Vaittinen <mazziesaccount@gmail.com>");
MODULE_DESCRIPTION("Driver for ROHM BM1390 pressure sensor");
MODULE_LICENSE("GPL");