summaryrefslogtreecommitdiffstats
path: root/upstream/debian-bookworm/man5/sane-hpsj5s.5
blob: ac0f69ab5abc2536c93132a2ad53504469e3161a (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
.TH sane\-hpsj5s 5 "13 Jul 2008" "" "SANE Scanner Access Now Easy"
.IX sane\-hpsj5s
.SH NAME
sane\-hpsj5s \- SANE backend for HP ScanJet 5S sheet-fed scanner
.SH DESCRIPTION
The
.B sane\-hpsj5s
library implements a SANE (Scanner Access Now Easy) backend that
provides access to a parallel port Hewlett-Packard ScanJet 5S scanner.
.PP
IMPORTANT: this is alpha code. Don't expect this to work
correctly. Many functions are missing, others contain errors. In some
cases, your computer might even hang. It cannot be excluded (although
I consider it extremely improbable) that your scanner will be
damaged.
.PP
LIMITATIONS: For now this backend works only on Linux.  This limitation
is due to dependence on the
.BR libieee1284 (3)
library. If your system supports
.BR libieee1284 (3)
too, this backend should work. If you ported
.BR libieee1284 (3)
for your platform, please let me know. Your system should support
.B EPP
(or
.BR EPP+ECP )
mode to operate this scanner. Future versions will support ECP and SPP
(Nibble and Byte) modes also. It's planned to support scanners not only
at daisy-chain position 0, but anywhere. Support for multiple scanners could
be implemented too.
.PP
Current version implements only gray scale scanning. True Color and B/W modes are
not supported for now.
.PP
That said, TESTERS ARE WELCOME. Send your bug reports and comments to
Max Vorobiev
.RI < pcwizard@yandex.ru >.
.PP
.SH "DEVICE NAMES"
This backend expects device names of the form:
.PP
.RS
.I special
.RE
.PP
Where
.I special
is the parallel port name in form,
.BR libieee1284 (3)
expects. It seems to be system dependent. Under Linux it's parport0, parport1, etc.
.SH CONFIGURATION
The contents of the
.I hpsj5s.conf
file is a list of parport names that correspond to HP ScanJet 5S
scanners.  Empty lines and lines starting with a hash mark (#) are
ignored.  Only one device name can be listed in
.IR hpsj5s.conf
for this moment. Future versions will support daisy chain selection.

.SH TIPS
.PP
It seems that HP ScanJet 5S scanner uses software noise correction. This
feature, along with gamma correction and calibration, are not implemented for now.
They will be handled in future versions.
Native resolution for this scanner is 300 DPI.
Other modes may present aliasing artifacts.
.PP
.SH FILES
.TP
.I /etc/sane.d/hpsj5s.conf
The backend configuration file (see also description of
.B SANE_CONFIG_DIR
below).
.TP
.I /usr/lib/x86_64-linux-gnu/sane/libsane\-hpsj5s.a
The static library implementing this backend.
.TP
.I /usr/lib/x86_64-linux-gnu/sane/libsane\-hpsj5s.so
The shared library implementing this backend (present on systems that
support dynamic loading).
.SH ENVIRONMENT
.TP
.B SANE_CONFIG_DIR
This environment variable specifies the list of directories that may
contain the configuration file.  On *NIX systems, the directories are
separated by a colon (`:'), under OS/2, they are separated by a
semi-colon (`;').  If this variable is not set, the configuration file
is searched in two default directories: first, the current working
directory (".") and then in
.IR /etc/sane.d .
If the value of the
environment variable ends with the directory separator character, then
the default directories are searched after the explicitly specified
directories.  For example, setting
.B SANE_CONFIG_DIR
to "/tmp/config:" would result in directories
.IR tmp/config ,
.IR . ,
and
.I "/etc/sane.d"
being searched (in this order).
.TP
.B SANE_DEBUG_HPSJ5S
If the library was compiled with debug support enabled, this environment
variable controls the debug level for this backend.  Higher debug levels
increase the verbosity of the output.

.SH "SEE ALSO"
.BR sane (7),
.BR libieee1284 (3)
.br
.I http://hpsj5s.sourceforge.net
.br
.I http://cyberelk.net/tim/libieee1284
.br
.SH AUTHOR
Max Vorobiev
.br
Man page mostly based on
.IR canon.man .