summaryrefslogtreecommitdiffstats
path: root/upstream/fedora-rawhide/man5/sane-mustek_usb.5
blob: a2018b7e5b37774635e8337137d5ff66e0e977af (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
.TH sane\-mustek_usb 5 "13 Jul 2008" "" "SANE Scanner Access Now Easy"
.IX sane\-mustek_usb
.SH NAME
sane\-mustek_usb \- SANE backend for Mustek USB flatbed scanners
.SH DESCRIPTION
The
.B sane\-mustek_usb
library implements a SANE (Scanner Access Now Easy) backend that provides
access to Mustek USB flatbed scanners (including a clone from Trust).  At
present, the following scanners are known to work more or less with this
backend:
.PP
.RS
Mustek 600 CU
.br
Mustek 1200 UB
.br
Mustek 1200 CU
.br
Mustek 1200 CU Plus
.br
Trust Compact Scan USB 19200
.br
.RE
.PP
More details can be found on the Mustek USB backend homepage
.IR http://www.meier\-geinitz.de/sane/mustek_usb\-backend/ .
.PP
The Mustek BearPaw 1200 and 2400 scanners are supported by the plustek
backend. See
.BR sane\-plustek (5)
for details. The Mustek BearPaw 1200F is supported by the MA-1509 backend. See
.BR sane\-ma1509 (5)
for details. Other Mustek USB scanners are supported by the gt68xx backend,
see
.BR sane\-gt68xx (5).
.PP
This backend can only work with scanners that are already detected by the
operating system. See
.BR sane\-usb (5)
for details.
.PP
If you own a Mustek (or Trust) scanner other than the ones listed above that
works with this backend, please let me know this by sending the scanner's
exact model name and the USB vendor and device ids (e.g. from
.I /proc/bus/usb/devices
or syslog) to me.

.SH "DEVICE NAMES"
This backend expects device names of the form:
.PP
.RS
.I special
.RE
.PP
Where
.I special
is a path-name for the special device that corresponds to a USB scanner.
With Linux, such a device name could be
.I /dev/usb/scanner0
or
.IR /dev/usbscanner1 ,
for example.
.PP
For FreeBSD use
.IR /dev/uscanner0 .

.SH CONFIGURATION
The contents of the
.I mustek_usb.conf
file is a list of options and device names that correspond to Mustek
USB scanners.  Empty lines and lines starting with a hash mark (#) are
ignored. If a device name is placed in
.IR mustek_usb.conf ,
it must be followed by a line containing the keyword
.B option
and an option specifying the scanner type. The following options can be used:
.BR 600cu ,
.BR 1200cu ,
.BR 1200cu_plus ,
.BR 1200ub .
For the Trust Compact Scan USB 19200 use `option 1200ub'.
.PP
Instead of using the device name, the scanner can be autodetected by
.B "usb vendor_id product_id"
statements which are already included into
.IR mustek_usb.conf .
This is only supported with Linux 2.4.8 and higher and all systems that
support libsub. "vendor_id" and "product_id" are hexadecimal numbers that
identify the scanner. If this doesn't work, a device name and the option
specifying the scanner type must be placed in
.I mustek_usb.conf
as described above.
.PP
The global
.B option max_block_size
can be used to limit the amount of data acquired in one turn from the USB
system. It may be worth trying, if USB errors occur.
.PP
A sample configuration file is shown below:
.PP
.RS
# Comment
.br
option max_block_size 1024
.br
usb 0x055f 0x0001
.br
/dev/usb/scanner0
.br
option 600cu
.RE
.PP
The first line is ignored. The second line sets the buffer size to a maximum of
1024 bytes.  The third line tries to autodetect a scanner with vendor id 0x055f
and product id 0x0001 (Mustek 1200 CU). The fourth line tells the backend to
attach to
.I /dev/usb/scanner0
and the fifth line specifies that
.I /dev/usb/scanner0
is a Mustek 600 CU.
.SH FILES
.TP
.I /etc/sane.d/mustek_usb.conf
The backend configuration file (see also description of
.B SANE_CONFIG_DIR
below).
.TP
.I /usr/lib64/sane/libsane\-mustek_usb.a
The static library implementing this backend.
.TP
.I /usr/lib64/sane/libsane\-mustek_usb.so
The shared library implementing this backend (present on systems that
support dynamic loading).
.SH ENVIRONMENT
.TP
.B SANE_CONFIG_DIR
This environment variable specifies the list of directories that may
contain the configuration file.  On *NIX systems, the directories are
separated by a colon (`:'), under OS/2, they are separated by a
semi-colon (`;').  If this variable is not set, the configuration file
is searched in two default directories: first, the current working
directory (".") and then in
.IR /etc/sane.d .
If the value of the
environment variable ends with the directory separator character, then
the default directories are searched after the explicitly specified
directories.  For example, setting
.B SANE_CONFIG_DIR
to "/tmp/config:" would result in directories
.IR tmp/config ,
.IR . ,
and
.I "/etc/sane.d"
being searched (in this order).
.TP
.B SANE_DEBUG_MUSTEK_USB
If the library was compiled with debug support enabled, this
environment variable controls the debug level for this backend.  Higher
debug levels increase the verbosity of the output.

.ft CR
.nf
Value  Description
0      no output
1      print fatal errors
2      print important messages
3      print non-fatal errors and less important messages
4      print all but debugging messages
5      print high level debugging messages
6      print medium level debugging messages
7      print low level debugging messages
.fi
.ft R

Example:
export SANE_DEBUG_MUSTEK_USB=4

.SH "SEE ALSO"
.BR sane (7),
.BR sane\-usb (5),
.BR sane\-mustek (5),
.BR sane\-mustek_pp (5),
.BR sane\-plustek (5),
.BR sane\-gt68xx (5),
.BR sane\-ma1509 (5)
.br
.IR /usr/share/doc/sane-backends/mustek_usb/mustek_usb.CHANGES ,
.br
.I /usr/share/doc/sane-backends/mustek_usb/mustek_usb.TODO
.br
.I http://www.meier\-geinitz.de/sane/mustek_usb\-backend/

.SH AUTHOR
Henning Meier-Geinitz
.RI < henning@meier\-geinitz.de >
.br
This backend is based on the Mustek 1200ub backend from Mustek, maintained by
Tom Wang.

.SH BUGS
These devices have a hardware bug: Once data is written to them, they can't be
reset (toggle = DATA0). That means, any operation that tries to reset the
device will result in running into timeouts.

In earlier versions this backend failed when it was loaded the second time in
some configurations. The only choice was to replug the scanner in this case. The
backend uses a workaround for that bug now but it's only tested on
Linux. Reports for other operating systems are appreciated.

.PP
More detailed bug information is available at the Mustek backend homepage
.IR http://www.meier\-geinitz.de/sane/mustek_usb\-backend/ .