summaryrefslogtreecommitdiffstats
path: root/upstream/opensuse-tumbleweed/man5/sane-teco1.5
blob: 0761fbe2f216e3a1386e46976070016c2200d759 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
.TH sane\-teco1 5 "14 Jul 2008" "" "SANE Scanner Access Now Easy"
.IX sane\-teco1
.SH NAME
sane\-teco1 \- SANE backend for TECO / RELISYS scanners
.SH DESCRIPTION
The
.B sane\-teco1
library implements a SANE (Scanner Access Now Easy) backend that
provides access to some TECO SCSI flatbed scanners. This backend
should be considered
.B beta-quality
software! TECO scanners are sold under
various brands like RELISYS, PIOTECH, TRUST. This backend may or
may not support yours.
.PP
The scanners that should work with this backend are:
.PP
.RS
.ft CR
.nf
   Vendor Model           TECO model      status
----------------------  --------------  -----------
  Relisys AVEC 2400        VM3520        tested
  Relisys AVEC 2412        VM3520+       tested
  Relisys AVEC 4800        VM4530        untested
  Relisys AVEC 4816        VM4530+       untested
  Relisys RELI 2400        VM3530        untested
  Relisys RELI 2412        VM3530+       tested
  Relisys RELI 2412        VM3530+       untested
  Relisys RELI 4816        VM4540        tested
  Relisys RELI 4830        VM4542        tested
  Relisys RELI 9600        VM6530        untested
  Relisys RELI 9612        VM6530*       untested
  Relisys RELI 9624        VM6530+       untested
  Relisys RELI 9630        VM6540        untested
  Relisys RELI DS15        VM3440        untested
  Relisys RELI DS6         VM3420        untested
  Dextra  DF-600P          VM3510        tested
  Dextra  DF-4830T         VM4542        untested
  Dextra  DF-1200T+        VM3530+       untested
  Dextra  DF-9624          VM6530+       untested
.fi
.ft R
.RE

Note that the untested scanner will not be directly supported. You
should contact the author for that.

The TECO VM number can usually be found at the back of the scanner. It
is also part of the FCC ID.
.I sane\-find\-scanner \-v
will also show the
SCSI inquiry, and if it is a TECO scanner, the name will be there too.

The options the backend supports can either be selected through
command line options to programs like
.BR scanimage (1)
or through GUI
elements in
.BR xscanimage (1)
or
.BR xsane (1).

.br
If you have any success with a scanner not listed here, or if you notice
any strange behavior, please report to the backend maintainer or to
the SANE mailing list.

Valid command line options and their syntax can be listed by using:

.RS
scanimage \-\-help \-d teco1
.RE

.TP
.B Scan Mode

.TP
.B \-\-mode Black & White|Grayscale|Color
Selects the basic mode of operation of the scanner. Valid choices are
.IR "Black & White" ,
.I "Grayscale"
and
.IR Color .

The
.I Black & White
mode is for black and white only (1 bit).
.I Grayscale
will produce 256 levels of gray (8 bits).
.I Color
will produce a 24 bit color image.

.TP
.B \-\-resolution 1..600
Selects the resolution for a scan. The scanner can do all resolutions
between 1 and 600, in increments of 1.


.TP
.B Geometry options

.TP
.B \-l \-t \-x \-y
Controls the scan area:
.B \-l
sets the top left x coordinate,
.B \-t
the top left y coordinate,
.B \-x
selects the width and
.B \-y
the height of the scan area. All parameters are specified in millimeters by default.


.TP
.B Enhancement options

.TP
.B \-\-custom\-gamma
(color mode only) allows the user to specify a gamma table (see the
next 3 parameters).

.TP
.B \-\-red\-gamma\-table
Can be used to download a user defined gamma table for the red channel.
The table must be 256 bytes long. Color mode only.

.TP
.B \-\-green\-gamma\-table
Can be used to download a user defined gamma table for the green channel.
The table must be 256 bytes long. Color mode only.

.TP
.B \-\-blue\-gamma\-table
Can be used to download a user defined gamma table for the blue channel.
The table must be 256 bytes long. Color mode only.

.TP
.B \-\-dither Line art|2x2|3x3|4x4 bayer|4x4 smooth|8x8 bayer|8x8 smooth|8x8 horizontal|8x8 vertical
Select the dither mask to use. Black & White only.


.TP
.B \-\-preview
Requests a preview scan. The resolution used is 22 dpi
and the scan area is the maximum allowed. The scan mode is user
selected. The default is "no".


.SH CONFIGURATION FILE
The configuration file
.I /etc/sane.d/teco1.conf
supports only one item: the device name to use (eg
.IR /dev/scanner ).


.SH FILES
.TP
.I /usr/lib64/sane/libsane\-teco1.a
The static library implementing this backend.
.TP
.I /usr/lib64/sane/libsane\-teco1.so
The shared library implementing this backend (present on systems that
support dynamic loading).


.SH ENVIRONMENT
.TP
.B SANE_DEBUG_TECO1
If the library was compiled with debug support enabled, this
environment variable controls the debug level for this backend. E.g.,
a value of 128 requests all debug output to be printed. Smaller levels
reduce verbosity.


.SH LIMITATIONS
The windows TWAIN driver has many more options than this SANE
backend. However they are only software adjustments. This backend only
implements what the scanner can support.


.SH BUGS
None known.

.SH "SEE ALSO"
.BR sane\-scsi (5),
.BR scanimage (1),
.BR xscanimage (1),
.BR xsane (1),
.BR sane (7)

.SH AUTHOR
.TP
The package is actively maintained by Frank Zago.
.I http://www.zago.net/sane/#teco

.SH CREDITS

Thanks to Gerard Delafond for the VM4542 support.
Thanks to Jean-Yves Simon for the VM3510 support.