+### Understand the alert
+
+This alert is related to the Adaptec RAID controller, which manages the logical device statuses on your RAID configuration. When this alert is triggered in a critical state, it means that a logical device state value is in a degraded or failed state, indicating that one or more disks in your RAID configuration have failed.
+
+### Troubleshoot the alert
+
+Data is priceless. Before taking any action, ensure to have necessary backups in place. Netdata is not liable for any loss or corruption of any data, database, or software.
+
+Your Adaptec RAID card will automatically start rebuilding a faulty hard drive when you replace it with a healthy one. Sometimes this operation may take some time or may not start automatically.
+
+#### 1. Verify that a rebuild is not in process
+
+Check if the rebuild process is already running:
+
+```
+root@netdata # arcconf GETSTATUS <Controller_num>
+```
+
+Replace `<Controller_num>` with the number of your RAID controller.
+
+#### 2. Check for idle/missing segments of logical devices
+
+Examine the output of the previous command to find any segments that are idle or missing.
+
+#### 3. Manually change your ld status
+
+If the rebuild process hasn't started automatically, change the logical device (ld) status manually. This action will trigger a rebuild on your RAID:
+
+```
+root@netdata # arcconf SETSTATE <Controller_num> LOGICALDRIVE <LD_num> OPTIMAL ADVANCED nocheck noprompt
+```
+
+Replace `<Controller_num>` with the number of your RAID controller and `<LD_num>` with the number of the logical device.
+
+### Useful resources
+