1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
|
plugin_name: freeipmi.plugin
modules:
- meta:
plugin_name: freeipmi.plugin
module_name: freeipmi
monitored_instance:
name: Intelligent Platform Management Interface (IPMI)
link: "https://en.wikipedia.org/wiki/Intelligent_Platform_Management_Interface"
categories:
- data-collection.hardware-devices-and-sensors
icon_filename: "netdata.png"
related_resources:
integrations:
list: []
info_provided_to_referring_integrations:
description: ""
keywords:
- sensors
- ipmi
- freeipmi
- ipmimonitoring
most_popular: true
overview:
data_collection:
metrics_description: |
"Monitor enterprise server sensor readings, event log entries, and hardware statuses to ensure reliable server operations."
method_description: |
The plugin uses open source library IPMImonitoring to communicate with sensors.
supported_platforms:
include: []
exclude: []
multi_instance: true
additional_permissions:
description: "The plugin needs setuid."
default_behavior:
auto_detection:
description: ""
limits:
description: ""
performance_impact:
description: "Linux kernel module for IPMI can create big overhead."
setup:
prerequisites:
list:
- title: Install freeipmi.plugin
description: |
When using our official DEB/RPM packages, the FreeIPMI plugin is included in a separate package named `netdata-plugin-freeipmi` which needs to be manually installed using your system package manager. It is not installed automatically due to the large number of dependencies it requires.
When using a static build of Netdata, the FreeIPMI plugin will be included and installed automatically, though you will still need to have FreeIPMI installed on your system to be able to use the plugin.
When using a local build of Netdata, you need to ensure that the FreeIPMI development packages (typically called `libipmimonitoring-dev`, `libipmimonitoring-devel`, or `freeipmi-devel`) are installed when building Netdata.
- title: Preliminary actions
description: |
If you have not previously used IPMI on your system, you will probably need to run the `ipmimonitoring` command as root
to initialize IPMI settings so that the Netdata plugin works correctly. It should return information about available sensors on the system.
configuration:
file:
name: "netdata.conf"
section_name: "[plugin:freeipmi]"
options:
description: |
The configuration is set using command line options:
```
# netdata.conf
[plugin:freeipmi]
command options = opt1 opt2 ... optN
```
To display a help message listing the available command line options:
```bash
./usr/libexec/netdata/plugins.d/freeipmi.plugin --help
```
folding:
title: "Command options"
enabled: true
list:
- name: SECONDS
description: Data collection frequency.
default_value: ""
required: false
- name: debug
description: Enable verbose output.
default_value: disabled
required: false
- name: no-sel
description: Disable System Event Log (SEL) collection.
default_value: disabled
required: false
- name: reread-sdr-cache
description: Re-read SDR cache on every iteration.
default_value: disabled
required: false
- name: interpret-oem-data
description: Attempt to parse OEM data.
default_value: disabled
required: false
- name: assume-system-event-record
description: treat illegal SEL events records as normal.
default_value: disabled
required: false
- name: ignore-non-interpretable-sensors
description: Do not read sensors that cannot be interpreted.
default_value: disabled
required: false
- name: bridge-sensors
description: Bridge sensors not owned by the BMC.
default_value: disabled
required: false
- name: shared-sensors
description: Enable shared sensors if found.
default_value: disabled
required: false
- name: no-discrete-reading
description: Do not read sensors if their event/reading type code is invalid.
default_value: enabled
required: false
- name: ignore-scanning-disabled
description: Ignore the scanning bit and read sensors no matter what.
default_value: disabled
required: false
- name: assume-bmc-owner
description: Assume the BMC is the sensor owner no matter what (usually bridging is required too).
default_value: disabled
required: false
- name: hostname HOST
description: Remote IPMI hostname or IP address.
default_value: local
required: false
- name: username USER
description: Username that will be used when connecting to the remote host.
default_value: ""
required: false
- name: password PASS
description: Password that will be used when connecting to the remote host.
default_value: ""
required: false
- name: noauthcodecheck / no-auth-code-check
description: Don't check the authentication codes returned.
default_value: ""
required: false
- name: driver-type IPMIDRIVER
description: Specify the driver type to use instead of doing an auto selection. The currently available outofband drivers are LAN and LAN_2_0, which perform IPMI 1.5 and IPMI 2.0 respectively. The currently available inband drivers are KCS, SSIF, OPENIPMI and SUNBMC.
default_value: ""
required: false
- name: sdr-cache-dir PATH
description: SDR cache files directory.
default_value: /tmp
required: false
- name: sensor-config-file FILE
description: Sensors configuration filename.
default_value: system default
required: false
- name: sel-config-file FILE
description: SEL configuration filename.
default_value: system default
required: false
- name: ignore N1,N2,N3,...
description: Sensor IDs to ignore.
default_value: ""
required: false
- name: ignore-status N1,N2,N3,...
description: Sensor IDs to ignore status (nominal/warning/critical).
default_value: ""
required: false
- name: -v
description: Print version and exit.
default_value: ""
required: false
- name: --help
description: Print usage message and exit.
default_value: ""
required: false
examples:
folding:
enabled: true
title: "Config"
list:
- name: Decrease data collection frequency
description: Basic example decreasing data collection frequency. The minimum `update every` is 5 (enforced internally by the plugin). IPMI is slow and CPU hungry. So, once every 5 seconds is pretty acceptable.
config: |
[plugin:freeipmi]
update every = 10
folding:
enabled: false
- name: Disable SEL collection
description: Append to `command options =` the options you need.
config: |
[plugin:freeipmi]
command options = no-sel
- name: Ignore specific sensors
description: |
Specific sensor IDs can be excluded from freeipmi tools by editing `/etc/freeipmi/freeipmi.conf` and setting the IDs to be ignored at `ipmi-sensors-exclude-record-ids`.
**However this file is not used by `libipmimonitoring`** (the library used by Netdata's `freeipmi.plugin`).
To find the IDs to ignore, run the command `ipmimonitoring`. The first column is the wanted ID:
ID | Name | Type | State | Reading | Units | Event
1 | Ambient Temp | Temperature | Nominal | 26.00 | C | 'OK'
2 | Altitude | Other Units Based Sensor | Nominal | 480.00 | ft | 'OK'
3 | Avg Power | Current | Nominal | 100.00 | W | 'OK'
4 | Planar 3.3V | Voltage | Nominal | 3.29 | V | 'OK'
5 | Planar 5V | Voltage | Nominal | 4.90 | V | 'OK'
6 | Planar 12V | Voltage | Nominal | 11.99 | V | 'OK'
7 | Planar VBAT | Voltage | Nominal | 2.95 | V | 'OK'
8 | Fan 1A Tach | Fan | Nominal | 3132.00 | RPM | 'OK'
9 | Fan 1B Tach | Fan | Nominal | 2150.00 | RPM | 'OK'
10 | Fan 2A Tach | Fan | Nominal | 2494.00 | RPM | 'OK'
11 | Fan 2B Tach | Fan | Nominal | 1825.00 | RPM | 'OK'
12 | Fan 3A Tach | Fan | Nominal | 3538.00 | RPM | 'OK'
13 | Fan 3B Tach | Fan | Nominal | 2625.00 | RPM | 'OK'
14 | Fan 1 | Entity Presence | Nominal | N/A | N/A | 'Entity Present'
15 | Fan 2 | Entity Presence | Nominal | N/A | N/A | 'Entity Present'
...
`freeipmi.plugin` supports the option `ignore` that accepts a comma separated list of sensor IDs to ignore. To configure it set on `netdata.conf`:
config: |
[plugin:freeipmi]
command options = ignore 1,2,3,4,...
troubleshooting:
problems:
list:
- name: Debug Mode
description: |
You can run `freeipmi.plugin` with the debug option enabled, to troubleshoot issues with it. The output should give you clues as to why the collector isn't working.
- Navigate to the `plugins.d` directory, usually at `/usr/libexec/netdata/plugins.d/`. If that's not the case on your system, open `netdata.conf` and look for the `plugins` setting under `[directories]`.
```bash
cd /usr/libexec/netdata/plugins.d/
```
- Switch to the `netdata` user.
```bash
sudo -u netdata -s
```
- Run the `freeipmi.plugin` in debug mode:
```bash
./freeipmi.plugin 5 debug
```
- name: kimpi0 CPU usage
description: |
There have been reports that kipmi is showing increased CPU when the IPMI is queried. To lower the CPU consumption of the system you can issue this command:
```sh
echo 10 > /sys/module/ipmi_si/parameters/kipmid_max_busy_us
```
You can also permanently set the above setting by creating the file `/etc/modprobe.d/ipmi.conf` with this content:
```sh
# prevent kipmi from consuming 100% CPU
options ipmi_si kipmid_max_busy_us=10
```
This instructs the kernel IPMI module to pause for a tick between checking IPMI. Querying IPMI will be a lot slower now (e.g. several seconds for IPMI to respond), but `kipmi` will not use any noticeable CPU.
You can also use a higher number (this is the number of microseconds to poll IPMI for a response, before waiting for a tick).
alerts:
- name: ipmi_sensor_state
link: https://github.com/netdata/netdata/blob/master/health/health.d/ipmi.conf
metric: ipmi.sensor_state
info: IPMI sensor ${label:sensor} (${label:component}) state
metrics:
folding:
title: Metrics
enabled: false
description: |
The plugin does a speed test when it starts, to find out the duration needed by the IPMI processor to respond. Depending on the speed of your IPMI processor, charts may need several seconds to show up on the dashboard.
availability: []
scopes:
- name: global
description: These metrics refer to the entire monitored application.
labels: []
metrics:
- name: ipmi.sel
description: IPMI Events
unit: "events"
chart_type: area
dimensions:
- name: events
- name: sensor
description: ""
labels:
- name: sensor
description: The sensor name
- name: type
description: One of 45 recognized sensor types (Battery, Voltage...)
- name: component
description: One of 25 recognized components (Processor, Peripheral).
metrics:
- name: ipmi.sensor_state
description: IPMI Sensors State
unit: "state"
chart_type: line
dimensions:
- name: nominal
- name: critical
- name: warning
- name: unknown
- name: ipmi.sensor_temperature_c
description: IPMI Sensor Temperature Celsius
unit: "Celsius"
chart_type: line
dimensions:
- name: temperature
- name: ipmi.sensor_temperature_f
description: IPMI Sensor Temperature Fahrenheit
unit: "Fahrenheit"
chart_type: line
dimensions:
- name: temperature
- name: ipmi.sensor_voltage
description: IPMI Sensor Voltage
unit: "Volts"
chart_type: line
dimensions:
- name: voltage
- name: ipmi.sensor_ampere
description: IPMI Sensor Current
unit: "Amps"
chart_type: line
dimensions:
- name: ampere
- name: ipmi.sensor_fan_speed
description: IPMI Sensor Fans Speed
unit: "RPM"
chart_type: line
dimensions:
- name: rotations
- name: ipmi.sensor_power
description: IPMI Sensor Power
unit: "Watts"
chart_type: line
dimensions:
- name: power
- name: ipmi.sensor_reading_percent
description: IPMI Sensor Reading Percentage
unit: "%"
chart_type: line
dimensions:
- name: percentage
|