1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
|
SMRS DEFINITIONS IMPLICIT TAGS ::=
BEGIN
SMR-Bind ::= SEQUENCE {
sc-address SMS-Address,
password Password,
...
}
ub-password-length INTEGER ::= 20
IMSI-Address ::= OCTET STRING
SMS-Address ::= SEQUENCE {
address-type INTEGER {
unknown-type (0),
internat-number (1),
national-number (2),
net-spec-number (3),
short-number (4)
},
numbering-plan INTEGER {
unknown-numbering (0),
iSDN-numbering (1),
data-network-numbering (3),
telex-numbering (4),
national-numbering (8),
private-numbering (9)
},
address-value CHOICE {
octet-format SemiOctetString
}
}
SemiOctetString ::= OCTET STRING
Password ::= PrintableString
SMR-Bind-Confirm ::= SEQUENCE {
...
}
SMR-Bind-Failure ::= SEQUENCE {
connect-fail-reason Connect-fail,
...
}
Connect-fail ::= INTEGER {
not-entitled (0),
tmp-overload (1),
tmp-failure (2),
id-or-passwd (3),
not-supported (4),
inv-SC-addr (5)
}
SMR-Unbind ::= SEQUENCE {
...
}
RPDataMT ::= SEQUENCE {
mt-priority-request BOOLEAN,
mt-mms BOOLEAN,
mt-message-reference RP-MR,
mt-originating-address SMS-Address,
mt-destination-address SMS-Address,
mt-user-data RP-UD,
mt-origVMSCAddr [1] SMS-Address OPTIONAL,
mt-tariffClass [2] SM-TC OPTIONAL,
...
}
RPDataMO ::= SEQUENCE {
mo-message-reference RP-MR,
mo-originating-address SMS-Address,
mo-user-data RP-UD,
origVMSCAddr [1] SMS-Address OPTIONAL ,
moimsi [2] IMSI-Address OPTIONAL,
...
}
RP-MR ::= INTEGER (0..65535)
RP-UD ::= OCTET STRING (SIZE (1..164))
SM-TC ::= INTEGER (0..65535)
RPAck ::= SEQUENCE {
message-reference RP-MR,
...
}
Error-reason ::= INTEGER {
unknown-subscriber (1),
illegal-subscriber (9),
teleservice-not-provisioned (11),
call-barred (13),
cug-reject (15),
sMS-ll-capabilities-not-prov (19),
error-in-MS (20),
facility-not-supported (21),
memory-capacity-exceeded (22),
absent-subscriber (29),
ms-busy-for-MT-sms (30),
system-failure (36),
illegal-equipment (44),
no-resp-to-paging (60),
gMSC-congestion (61),
dublicate-sm (70),
sC-congestion (101),
mS-not-SC-Subscriber (103),
invalid-sme-address (104)
}
RPError ::= SEQUENCE {
error-reason Error-reason,
msg-waiting-set BOOLEAN,
message-reference RP-MR,
alerting-MS-ISDN [1] SMS-Address OPTIONAL,
sm-diag-info [2] RP-UD OPTIONAL,
...
}
RPAlertSC ::= SEQUENCE {
ms-address SMS-Address,
message-reference RP-MR,
...
}
END
|