summaryrefslogtreecommitdiffstats
path: root/doc/rbd/iscsi-initiator-win.rst
diff options
context:
space:
mode:
authorDaniel Baumann <daniel.baumann@progress-linux.org>2024-04-07 18:45:59 +0000
committerDaniel Baumann <daniel.baumann@progress-linux.org>2024-04-07 18:45:59 +0000
commit19fcec84d8d7d21e796c7624e521b60d28ee21ed (patch)
tree42d26aa27d1e3f7c0b8bd3fd14e7d7082f5008dc /doc/rbd/iscsi-initiator-win.rst
parentInitial commit. (diff)
downloadceph-19fcec84d8d7d21e796c7624e521b60d28ee21ed.tar.xz
ceph-19fcec84d8d7d21e796c7624e521b60d28ee21ed.zip
Adding upstream version 16.2.11+ds.upstream/16.2.11+dsupstream
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'doc/rbd/iscsi-initiator-win.rst')
-rw-r--r--doc/rbd/iscsi-initiator-win.rst102
1 files changed, 102 insertions, 0 deletions
diff --git a/doc/rbd/iscsi-initiator-win.rst b/doc/rbd/iscsi-initiator-win.rst
new file mode 100644
index 000000000..e76b03d18
--- /dev/null
+++ b/doc/rbd/iscsi-initiator-win.rst
@@ -0,0 +1,102 @@
+-------------------------------------
+iSCSI Initiator for Microsoft Windows
+-------------------------------------
+
+**Prerequisite:**
+
+- Microsoft Windows Server 2016 or later
+
+**iSCSI Initiator, Discovery and Setup:**
+
+#. Install the iSCSI initiator driver and MPIO tools.
+
+#. Launch the MPIO program, click on the "Discover Multi-Paths" tab, check the
+ "Add support for iSCSI devices” box, and click "Add". This will require a
+ reboot.
+
+#. On the iSCSI Initiator Properties window, on the "Discovery" tab, add a target
+ portal. Enter the IP address or DNS name and Port of the Ceph iSCSI gateway.
+
+#. On the “Targets” tab, select the target and click on “Connect”.
+
+#. On the “Connect To Target” window, select the “Enable multi-path” option, and
+ click the “Advanced” button.
+
+#. Under the "Connet using" section, select a “Target portal IP” . Select the
+ “Enable CHAP login on” and enter the "Name" and "Target secret" values from the
+ Ceph iSCSI Ansible client credentials section, and click OK.
+
+#. Repeat steps 5 and 6 for each target portal defined when setting up
+ the iSCSI gateway.
+
+**Multipath IO Setup:**
+
+Configuring the MPIO load balancing policy, setting the timeout and
+retry options are using PowerShell with the ``mpclaim`` command. The
+rest is done in the iSCSI Initiator tool.
+
+.. note::
+ It is recommended to increase the ``PDORemovePeriod`` option to 120
+ seconds from PowerShell. This value might need to be adjusted based
+ on the application. When all paths are down, and 120 seconds
+ expires, the operating system will start failing IO requests.
+
+::
+
+ Set-MPIOSetting -NewPDORemovePeriod 120
+
+::
+
+ mpclaim.exe -l -m 1
+
+::
+
+ mpclaim -s -m
+ MSDSM-wide Load Balance Policy: Fail Over Only
+
+#. Using the iSCSI Initiator tool, from the “Targets” tab, click on
+ the “Devices...” button.
+
+#. From the Devices window, select a disk and click the
+ “MPIO...” button.
+
+#. On the "Device Details" window the paths to each target portal is
+ displayed. If using the ``ceph-ansible`` setup method, the
+ iSCSI gateway will use ALUA to tell the iSCSI initiator which path
+ and iSCSI gateway should be used as the primary path. The Load
+ Balancing Policy “Fail Over Only” must be selected
+
+::
+
+ mpclaim -s -d $MPIO_DISK_ID
+
+.. note::
+ For the ``ceph-ansible`` setup method, there will be one
+ Active/Optimized path which is the path to the iSCSI gateway node
+ that owns the LUN, and there will be an Active/Unoptimized path for
+ each other iSCSI gateway node.
+
+**Tuning:**
+
+Consider using the following registry settings:
+
+- Windows Disk Timeout
+
+ ::
+
+ HKEY_LOCAL_MACHINE\System\CurrentControlSet\Services\Disk
+
+ ::
+
+ TimeOutValue = 65
+
+- Microsoft iSCSI Initiator Driver
+
+ ::
+
+ HKEY_LOCAL_MACHINE\\SYSTEM\CurrentControlSet\Control\Class\{4D36E97B-E325-11CE-BFC1-08002BE10318}\<Instance_Number>\Parameters
+
+ ::
+
+ LinkDownTime = 25
+ SRBTimeoutDelta = 15