summaryrefslogtreecommitdiffstats
path: root/Documentation/networking/device_drivers/ethernet/intel/ice.rst
blob: dc2e60ced927c378b4c91b1eadb52085e5c7d46e (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
.. SPDX-License-Identifier: GPL-2.0+

=================================================================
Linux Base Driver for the Intel(R) Ethernet Controller 800 Series
=================================================================

Intel ice Linux driver.
Copyright(c) 2018-2021 Intel Corporation.

Contents
========

- Overview
- Identifying Your Adapter
- Important Notes
- Additional Features & Configurations
- Performance Optimization


The associated Virtual Function (VF) driver for this driver is iavf.

Driver information can be obtained using ethtool and lspci.

For questions related to hardware requirements, refer to the documentation
supplied with your Intel adapter. All hardware requirements listed apply to use
with Linux.

This driver supports XDP (Express Data Path) and AF_XDP zero-copy. Note that
XDP is blocked for frame sizes larger than 3KB.


Identifying Your Adapter
========================
For information on how to identify your adapter, and for the latest Intel
network drivers, refer to the Intel Support website:
https://www.intel.com/support


Important Notes
===============

Packet drops may occur under receive stress
-------------------------------------------
Devices based on the Intel(R) Ethernet Controller 800 Series are designed to
tolerate a limited amount of system latency during PCIe and DMA transactions.
If these transactions take longer than the tolerated latency, it can impact the
length of time the packets are buffered in the device and associated memory,
which may result in dropped packets. These packets drops typically do not have
a noticeable impact on throughput and performance under standard workloads.

If these packet drops appear to affect your workload, the following may improve
the situation:

1) Make sure that your system's physical memory is in a high-performance
   configuration, as recommended by the platform vendor. A common
   recommendation is for all channels to be populated with a single DIMM
   module.
2) In your system's BIOS/UEFI settings, select the "Performance" profile.
3) Your distribution may provide tools like "tuned," which can help tweak
   kernel settings to achieve better standard settings for different workloads.


Configuring SR-IOV for improved network security
------------------------------------------------
In a virtualized environment, on Intel(R) Ethernet Network Adapters that
support SR-IOV, the virtual function (VF) may be subject to malicious behavior.
Software-generated layer two frames, like IEEE 802.3x (link flow control), IEEE
802.1Qbb (priority based flow-control), and others of this type, are not
expected and can throttle traffic between the host and the virtual switch,
reducing performance. To resolve this issue, and to ensure isolation from
unintended traffic streams, configure all SR-IOV enabled ports for VLAN tagging
from the administrative interface on the PF. This configuration allows
unexpected, and potentially malicious, frames to be dropped.

See "Configuring VLAN Tagging on SR-IOV Enabled Adapter Ports" later in this
README for configuration instructions.


Do not unload port driver if VF with active VM is bound to it
-------------------------------------------------------------
Do not unload a port's driver if a Virtual Function (VF) with an active Virtual
Machine (VM) is bound to it. Doing so will cause the port to appear to hang.
Once the VM shuts down, or otherwise releases the VF, the command will
complete.


Important notes for SR-IOV and Link Aggregation
-----------------------------------------------
Link Aggregation is mutually exclusive with SR-IOV.

- If Link Aggregation is active, SR-IOV VFs cannot be created on the PF.
- If SR-IOV is active, you cannot set up Link Aggregation on the interface.

Bridging and MACVLAN are also affected by this. If you wish to use bridging or
MACVLAN with SR-IOV, you must set up bridging or MACVLAN before enabling
SR-IOV. If you are using bridging or MACVLAN in conjunction with SR-IOV, and
you want to remove the interface from the bridge or MACVLAN, you must follow
these steps:

1. Destroy SR-IOV VFs if they exist
2. Remove the interface from the bridge or MACVLAN
3. Recreate SRIOV VFs as needed


Additional Features and Configurations
======================================

ethtool
-------
The driver utilizes the ethtool interface for driver configuration and
diagnostics, as well as displaying statistical information. The latest ethtool
version is required for this functionality. Download it at:
https://kernel.org/pub/software/network/ethtool/

NOTE: The rx_bytes value of ethtool does not match the rx_bytes value of
Netdev, due to the 4-byte CRC being stripped by the device. The difference
between the two rx_bytes values will be 4 x the number of Rx packets. For
example, if Rx packets are 10 and Netdev (software statistics) displays
rx_bytes as "X", then ethtool (hardware statistics) will display rx_bytes as
"X+40" (4 bytes CRC x 10 packets).


Viewing Link Messages
---------------------
Link messages will not be displayed to the console if the distribution is
restricting system messages. In order to see network driver link messages on
your console, set dmesg to eight by entering the following::

  # dmesg -n 8

NOTE: This setting is not saved across reboots.


Dynamic Device Personalization
------------------------------
Dynamic Device Personalization (DDP) allows you to change the packet processing
pipeline of a device by applying a profile package to the device at runtime.
Profiles can be used to, for example, add support for new protocols, change
existing protocols, or change default settings. DDP profiles can also be rolled
back without rebooting the system.

The DDP package loads during device initialization. The driver looks for
``intel/ice/ddp/ice.pkg`` in your firmware root (typically ``/lib/firmware/``
or ``/lib/firmware/updates/``) and checks that it contains a valid DDP package
file.

NOTE: Your distribution should likely have provided the latest DDP file, but if
ice.pkg is missing, you can find it in the linux-firmware repository or from
intel.com.

If the driver is unable to load the DDP package, the device will enter Safe
Mode. Safe Mode disables advanced and performance features and supports only
basic traffic and minimal functionality, such as updating the NVM or
downloading a new driver or DDP package. Safe Mode only applies to the affected
physical function and does not impact any other PFs. See the "Intel(R) Ethernet
Adapters and Devices User Guide" for more details on DDP and Safe Mode.

NOTES:

- If you encounter issues with the DDP package file, you may need to download
  an updated driver or DDP package file. See the log messages for more
  information.

- The ice.pkg file is a symbolic link to the default DDP package file.

- You cannot update the DDP package if any PF drivers are already loaded. To
  overwrite a package, unload all PFs and then reload the driver with the new
  package.

- Only the first loaded PF per device can download a package for that device.

You can install specific DDP package files for different physical devices in
the same system. To install a specific DDP package file:

1. Download the DDP package file you want for your device.

2. Rename the file ice-xxxxxxxxxxxxxxxx.pkg, where 'xxxxxxxxxxxxxxxx' is the
   unique 64-bit PCI Express device serial number (in hex) of the device you
   want the package downloaded on. The filename must include the complete
   serial number (including leading zeros) and be all lowercase. For example,
   if the 64-bit serial number is b887a3ffffca0568, then the file name would be
   ice-b887a3ffffca0568.pkg.

   To find the serial number from the PCI bus address, you can use the
   following command::

     # lspci -vv -s af:00.0 | grep -i Serial
     Capabilities: [150 v1] Device Serial Number b8-87-a3-ff-ff-ca-05-68

   You can use the following command to format the serial number without the
   dashes::

     # lspci -vv -s af:00.0 | grep -i Serial | awk '{print $7}' | sed s/-//g
     b887a3ffffca0568

3. Copy the renamed DDP package file to
   ``/lib/firmware/updates/intel/ice/ddp/``. If the directory does not yet
   exist, create it before copying the file.

4. Unload all of the PFs on the device.

5. Reload the driver with the new package.

NOTE: The presence of a device-specific DDP package file overrides the loading
of the default DDP package file (ice.pkg).


Intel(R) Ethernet Flow Director
-------------------------------
The Intel Ethernet Flow Director performs the following tasks:

- Directs receive packets according to their flows to different queues
- Enables tight control on routing a flow in the platform
- Matches flows and CPU cores for flow affinity

NOTE: This driver supports the following flow types:

- IPv4
- TCPv4
- UDPv4
- SCTPv4
- IPv6
- TCPv6
- UDPv6
- SCTPv6

Each flow type supports valid combinations of IP addresses (source or
destination) and UDP/TCP/SCTP ports (source and destination). You can supply
only a source IP address, a source IP address and a destination port, or any
combination of one or more of these four parameters.

NOTE: This driver allows you to filter traffic based on a user-defined flexible
two-byte pattern and offset by using the ethtool user-def and mask fields. Only
L3 and L4 flow types are supported for user-defined flexible filters. For a
given flow type, you must clear all Intel Ethernet Flow Director filters before
changing the input set (for that flow type).


Flow Director Filters
---------------------
Flow Director filters are used to direct traffic that matches specified
characteristics. They are enabled through ethtool's ntuple interface. To enable
or disable the Intel Ethernet Flow Director and these filters::

  # ethtool -K <ethX> ntuple <off|on>

NOTE: When you disable ntuple filters, all the user programmed filters are
flushed from the driver cache and hardware. All needed filters must be re-added
when ntuple is re-enabled.

To display all of the active filters::

  # ethtool -u <ethX>

To add a new filter::

  # ethtool -U <ethX> flow-type <type> src-ip <ip> [m <ip_mask>] dst-ip <ip>
  [m <ip_mask>] src-port <port> [m <port_mask>] dst-port <port> [m <port_mask>]
  action <queue>

  Where:
    <ethX> - the Ethernet device to program
    <type> - can be ip4, tcp4, udp4, sctp4, ip6, tcp6, udp6, sctp6
    <ip> - the IP address to match on
    <ip_mask> - the IPv4 address to mask on
              NOTE: These filters use inverted masks.
    <port> - the port number to match on
    <port_mask> - the 16-bit integer for masking
              NOTE: These filters use inverted masks.
    <queue> - the queue to direct traffic toward (-1 discards the
              matched traffic)

To delete a filter::

  # ethtool -U <ethX> delete <N>

  Where <N> is the filter ID displayed when printing all the active filters,
  and may also have been specified using "loc <N>" when adding the filter.

EXAMPLES:

To add a filter that directs packet to queue 2::

  # ethtool -U <ethX> flow-type tcp4 src-ip 192.168.10.1 dst-ip \
  192.168.10.2 src-port 2000 dst-port 2001 action 2 [loc 1]

To set a filter using only the source and destination IP address::

  # ethtool -U <ethX> flow-type tcp4 src-ip 192.168.10.1 dst-ip \
  192.168.10.2 action 2 [loc 1]

To set a filter based on a user-defined pattern and offset::

  # ethtool -U <ethX> flow-type tcp4 src-ip 192.168.10.1 dst-ip \
  192.168.10.2 user-def 0x4FFFF action 2 [loc 1]

  where the value of the user-def field contains the offset (4 bytes) and
  the pattern (0xffff).

To match TCP traffic sent from 192.168.0.1, port 5300, directed to 192.168.0.5,
port 80, and then send it to queue 7::

  # ethtool -U enp130s0 flow-type tcp4 src-ip 192.168.0.1 dst-ip 192.168.0.5
  src-port 5300 dst-port 80 action 7

To add a TCPv4 filter with a partial mask for a source IP subnet::

  # ethtool -U <ethX> flow-type tcp4 src-ip 192.168.0.0 m 0.255.255.255 dst-ip
  192.168.5.12 src-port 12600 dst-port 31 action 12

NOTES:

For each flow-type, the programmed filters must all have the same matching
input set. For example, issuing the following two commands is acceptable::

  # ethtool -U enp130s0 flow-type ip4 src-ip 192.168.0.1 src-port 5300 action 7
  # ethtool -U enp130s0 flow-type ip4 src-ip 192.168.0.5 src-port 55 action 10

Issuing the next two commands, however, is not acceptable, since the first
specifies src-ip and the second specifies dst-ip::

  # ethtool -U enp130s0 flow-type ip4 src-ip 192.168.0.1 src-port 5300 action 7
  # ethtool -U enp130s0 flow-type ip4 dst-ip 192.168.0.5 src-port 55 action 10

The second command will fail with an error. You may program multiple filters
with the same fields, using different values, but, on one device, you may not
program two tcp4 filters with different matching fields.

The ice driver does not support matching on a subportion of a field, thus
partial mask fields are not supported.


Flex Byte Flow Director Filters
-------------------------------
The driver also supports matching user-defined data within the packet payload.
This flexible data is specified using the "user-def" field of the ethtool
command in the following way:

.. table::

    ============================== ============================
    ``31    28    24    20    16`` ``15    12    8    4    0``
    ``offset into packet payload`` ``2 bytes of flexible data``
    ============================== ============================

For example,

::

  ... user-def 0x4FFFF ...

tells the filter to look 4 bytes into the payload and match that value against
0xFFFF. The offset is based on the beginning of the payload, and not the
beginning of the packet. Thus

::

  flow-type tcp4 ... user-def 0x8BEAF ...

would match TCP/IPv4 packets which have the value 0xBEAF 8 bytes into the
TCP/IPv4 payload.

Note that ICMP headers are parsed as 4 bytes of header and 4 bytes of payload.
Thus to match the first byte of the payload, you must actually add 4 bytes to
the offset. Also note that ip4 filters match both ICMP frames as well as raw
(unknown) ip4 frames, where the payload will be the L3 payload of the IP4
frame.

The maximum offset is 64. The hardware will only read up to 64 bytes of data
from the payload. The offset must be even because the flexible data is 2 bytes
long and must be aligned to byte 0 of the packet payload.

The user-defined flexible offset is also considered part of the input set and
cannot be programmed separately for multiple filters of the same type. However,
the flexible data is not part of the input set and multiple filters may use the
same offset but match against different data.


RSS Hash Flow
-------------
Allows you to set the hash bytes per flow type and any combination of one or
more options for Receive Side Scaling (RSS) hash byte configuration.

::

  # ethtool -N <ethX> rx-flow-hash <type> <option>

  Where <type> is:
    tcp4  signifying TCP over IPv4
    udp4  signifying UDP over IPv4
    tcp6  signifying TCP over IPv6
    udp6  signifying UDP over IPv6
  And <option> is one or more of:
    s     Hash on the IP source address of the Rx packet.
    d     Hash on the IP destination address of the Rx packet.
    f     Hash on bytes 0 and 1 of the Layer 4 header of the Rx packet.
    n     Hash on bytes 2 and 3 of the Layer 4 header of the Rx packet.


Accelerated Receive Flow Steering (aRFS)
----------------------------------------
Devices based on the Intel(R) Ethernet Controller 800 Series support
Accelerated Receive Flow Steering (aRFS) on the PF. aRFS is a load-balancing
mechanism that allows you to direct packets to the same CPU where an
application is running or consuming the packets in that flow.

NOTES:

- aRFS requires that ntuple filtering is enabled via ethtool.
- aRFS support is limited to the following packet types:

    - TCP over IPv4 and IPv6
    - UDP over IPv4 and IPv6
    - Nonfragmented packets

- aRFS only supports Flow Director filters, which consist of the
  source/destination IP addresses and source/destination ports.
- aRFS and ethtool's ntuple interface both use the device's Flow Director. aRFS
  and ntuple features can coexist, but you may encounter unexpected results if
  there's a conflict between aRFS and ntuple requests. See "Intel(R) Ethernet
  Flow Director" for additional information.

To set up aRFS:

1. Enable the Intel Ethernet Flow Director and ntuple filters using ethtool.

::

   # ethtool -K <ethX> ntuple on

2. Set up the number of entries in the global flow table. For example:

::

   # NUM_RPS_ENTRIES=16384
   # echo $NUM_RPS_ENTRIES > /proc/sys/net/core/rps_sock_flow_entries

3. Set up the number of entries in the per-queue flow table. For example:

::

   # NUM_RX_QUEUES=64
   # for file in /sys/class/net/$IFACE/queues/rx-*/rps_flow_cnt; do
   # echo $(($NUM_RPS_ENTRIES/$NUM_RX_QUEUES)) > $file;
   # done

4. Disable the IRQ balance daemon (this is only a temporary stop of the service
   until the next reboot).

::

   # systemctl stop irqbalance

5. Configure the interrupt affinity.

   See ``/Documentation/core-api/irq/irq-affinity.rst``


To disable aRFS using ethtool::

  # ethtool -K <ethX> ntuple off

NOTE: This command will disable ntuple filters and clear any aRFS filters in
software and hardware.

Example Use Case:

1. Set the server application on the desired CPU (e.g., CPU 4).

::

   # taskset -c 4 netserver

2. Use netperf to route traffic from the client to CPU 4 on the server with
   aRFS configured. This example uses TCP over IPv4.

::

   # netperf -H <Host IPv4 Address> -t TCP_STREAM


Enabling Virtual Functions (VFs)
--------------------------------
Use sysfs to enable virtual functions (VF).

For example, you can create 4 VFs as follows::

  # echo 4 > /sys/class/net/<ethX>/device/sriov_numvfs

To disable VFs, write 0 to the same file::

  # echo 0 > /sys/class/net/<ethX>/device/sriov_numvfs

The maximum number of VFs for the ice driver is 256 total (all ports). To check
how many VFs each PF supports, use the following command::

  # cat /sys/class/net/<ethX>/device/sriov_totalvfs

Note: You cannot use SR-IOV when link aggregation (LAG)/bonding is active, and
vice versa. To enforce this, the driver checks for this mutual exclusion.


Displaying VF Statistics on the PF
----------------------------------
Use the following command to display the statistics for the PF and its VFs::

  # ip -s link show dev <ethX>

NOTE: The output of this command can be very large due to the maximum number of
possible VFs.

The PF driver will display a subset of the statistics for the PF and for all
VFs that are configured. The PF will always print a statistics block for each
of the possible VFs, and it will show zero for all unconfigured VFs.


Configuring VLAN Tagging on SR-IOV Enabled Adapter Ports
--------------------------------------------------------
To configure VLAN tagging for the ports on an SR-IOV enabled adapter, use the
following command. The VLAN configuration should be done before the VF driver
is loaded or the VM is booted. The VF is not aware of the VLAN tag being
inserted on transmit and removed on received frames (sometimes called "port
VLAN" mode).

::

  # ip link set dev <ethX> vf <id> vlan <vlan id>

For example, the following will configure PF eth0 and the first VF on VLAN 10::

  # ip link set dev eth0 vf 0 vlan 10


Enabling a VF link if the port is disconnected
----------------------------------------------
If the physical function (PF) link is down, you can force link up (from the
host PF) on any virtual functions (VF) bound to the PF.

For example, to force link up on VF 0 bound to PF eth0::

  # ip link set eth0 vf 0 state enable

Note: If the command does not work, it may not be supported by your system.


Setting the MAC Address for a VF
--------------------------------
To change the MAC address for the specified VF::

  # ip link set <ethX> vf 0 mac <address>

For example::

  # ip link set <ethX> vf 0 mac 00:01:02:03:04:05

This setting lasts until the PF is reloaded.

NOTE: Assigning a MAC address for a VF from the host will disable any
subsequent requests to change the MAC address from within the VM. This is a
security feature. The VM is not aware of this restriction, so if this is
attempted in the VM, it will trigger MDD events.


Trusted VFs and VF Promiscuous Mode
-----------------------------------
This feature allows you to designate a particular VF as trusted and allows that
trusted VF to request selective promiscuous mode on the Physical Function (PF).

To set a VF as trusted or untrusted, enter the following command in the
Hypervisor::

  # ip link set dev <ethX> vf 1 trust [on|off]

NOTE: It's important to set the VF to trusted before setting promiscuous mode.
If the VM is not trusted, the PF will ignore promiscuous mode requests from the
VF. If the VM becomes trusted after the VF driver is loaded, you must make a
new request to set the VF to promiscuous.

Once the VF is designated as trusted, use the following commands in the VM to
set the VF to promiscuous mode.

For promiscuous all::

  # ip link set <ethX> promisc on
  Where <ethX> is a VF interface in the VM

For promiscuous Multicast::

  # ip link set <ethX> allmulticast on
  Where <ethX> is a VF interface in the VM

NOTE: By default, the ethtool private flag vf-true-promisc-support is set to
"off," meaning that promiscuous mode for the VF will be limited. To set the
promiscuous mode for the VF to true promiscuous and allow the VF to see all
ingress traffic, use the following command::

  # ethtool --set-priv-flags <ethX> vf-true-promisc-support on

The vf-true-promisc-support private flag does not enable promiscuous mode;
rather, it designates which type of promiscuous mode (limited or true) you will
get when you enable promiscuous mode using the ip link commands above. Note
that this is a global setting that affects the entire device. However, the
vf-true-promisc-support private flag is only exposed to the first PF of the
device. The PF remains in limited promiscuous mode regardless of the
vf-true-promisc-support setting.

Next, add a VLAN interface on the VF interface. For example::

  # ip link add link eth2 name eth2.100 type vlan id 100

Note that the order in which you set the VF to promiscuous mode and add the
VLAN interface does not matter (you can do either first). The result in this
example is that the VF will get all traffic that is tagged with VLAN 100.


Malicious Driver Detection (MDD) for VFs
----------------------------------------
Some Intel Ethernet devices use Malicious Driver Detection (MDD) to detect
malicious traffic from the VF and disable Tx/Rx queues or drop the offending
packet until a VF driver reset occurs. You can view MDD messages in the PF's
system log using the dmesg command.

- If the PF driver logs MDD events from the VF, confirm that the correct VF
  driver is installed.
- To restore functionality, you can manually reload the VF or VM or enable
  automatic VF resets.
- When automatic VF resets are enabled, the PF driver will immediately reset
  the VF and reenable queues when it detects MDD events on the receive path.
- If automatic VF resets are disabled, the PF will not automatically reset the
  VF when it detects MDD events.

To enable or disable automatic VF resets, use the following command::

  # ethtool --set-priv-flags <ethX> mdd-auto-reset-vf on|off


MAC and VLAN Anti-Spoofing Feature for VFs
------------------------------------------
When a malicious driver on a Virtual Function (VF) interface attempts to send a
spoofed packet, it is dropped by the hardware and not transmitted.

NOTE: This feature can be disabled for a specific VF::

  # ip link set <ethX> vf <vf id> spoofchk {off|on}


Jumbo Frames
------------
Jumbo Frames support is enabled by changing the Maximum Transmission Unit (MTU)
to a value larger than the default value of 1500.

Use the ifconfig command to increase the MTU size. For example, enter the
following where <ethX> is the interface number::

  # ifconfig <ethX> mtu 9000 up

Alternatively, you can use the ip command as follows::

  # ip link set mtu 9000 dev <ethX>
  # ip link set up dev <ethX>

This setting is not saved across reboots.


NOTE: The maximum MTU setting for jumbo frames is 9702. This corresponds to the
maximum jumbo frame size of 9728 bytes.

NOTE: This driver will attempt to use multiple page sized buffers to receive
each jumbo packet. This should help to avoid buffer starvation issues when
allocating receive packets.

NOTE: Packet loss may have a greater impact on throughput when you use jumbo
frames. If you observe a drop in performance after enabling jumbo frames,
enabling flow control may mitigate the issue.


Speed and Duplex Configuration
------------------------------
In addressing speed and duplex configuration issues, you need to distinguish
between copper-based adapters and fiber-based adapters.

In the default mode, an Intel(R) Ethernet Network Adapter using copper
connections will attempt to auto-negotiate with its link partner to determine
the best setting. If the adapter cannot establish link with the link partner
using auto-negotiation, you may need to manually configure the adapter and link
partner to identical settings to establish link and pass packets. This should
only be needed when attempting to link with an older switch that does not
support auto-negotiation or one that has been forced to a specific speed or
duplex mode. Your link partner must match the setting you choose. 1 Gbps speeds
and higher cannot be forced. Use the autonegotiation advertising setting to
manually set devices for 1 Gbps and higher.

Speed, duplex, and autonegotiation advertising are configured through the
ethtool utility. For the latest version, download and install ethtool from the
following website:

   https://kernel.org/pub/software/network/ethtool/

To see the speed configurations your device supports, run the following::

  # ethtool <ethX>

Caution: Only experienced network administrators should force speed and duplex
or change autonegotiation advertising manually. The settings at the switch must
always match the adapter settings. Adapter performance may suffer or your
adapter may not operate if you configure the adapter differently from your
switch.


Data Center Bridging (DCB)
--------------------------
NOTE: The kernel assumes that TC0 is available, and will disable Priority Flow
Control (PFC) on the device if TC0 is not available. To fix this, ensure TC0 is
enabled when setting up DCB on your switch.

DCB is a configuration Quality of Service implementation in hardware. It uses
the VLAN priority tag (802.1p) to filter traffic. That means that there are 8
different priorities that traffic can be filtered into. It also enables
priority flow control (802.1Qbb) which can limit or eliminate the number of
dropped packets during network stress. Bandwidth can be allocated to each of
these priorities, which is enforced at the hardware level (802.1Qaz).

DCB is normally configured on the network using the DCBX protocol (802.1Qaz), a
specialization of LLDP (802.1AB). The ice driver supports the following
mutually exclusive variants of DCBX support:

1) Firmware-based LLDP Agent
2) Software-based LLDP Agent

In firmware-based mode, firmware intercepts all LLDP traffic and handles DCBX
negotiation transparently for the user. In this mode, the adapter operates in
"willing" DCBX mode, receiving DCB settings from the link partner (typically a
switch). The local user can only query the negotiated DCB configuration. For
information on configuring DCBX parameters on a switch, please consult the
switch manufacturer's documentation.

In software-based mode, LLDP traffic is forwarded to the network stack and user
space, where a software agent can handle it. In this mode, the adapter can
operate in either "willing" or "nonwilling" DCBX mode and DCB configuration can
be both queried and set locally. This mode requires the FW-based LLDP Agent to
be disabled.

NOTE:

- You can enable and disable the firmware-based LLDP Agent using an ethtool
  private flag. Refer to the "FW-LLDP (Firmware Link Layer Discovery Protocol)"
  section in this README for more information.
- In software-based DCBX mode, you can configure DCB parameters using software
  LLDP/DCBX agents that interface with the Linux kernel's DCB Netlink API. We
  recommend using OpenLLDP as the DCBX agent when running in software mode. For
  more information, see the OpenLLDP man pages and
  https://github.com/intel/openlldp.
- The driver implements the DCB netlink interface layer to allow the user space
  to communicate with the driver and query DCB configuration for the port.
- iSCSI with DCB is not supported.


FW-LLDP (Firmware Link Layer Discovery Protocol)
------------------------------------------------
Use ethtool to change FW-LLDP settings. The FW-LLDP setting is per port and
persists across boots.

To enable LLDP::

  # ethtool --set-priv-flags <ethX> fw-lldp-agent on

To disable LLDP::

  # ethtool --set-priv-flags <ethX> fw-lldp-agent off

To check the current LLDP setting::

  # ethtool --show-priv-flags <ethX>

NOTE: You must enable the UEFI HII "LLDP Agent" attribute for this setting to
take effect. If "LLDP AGENT" is set to disabled, you cannot enable it from the
OS.


Flow Control
------------
Ethernet Flow Control (IEEE 802.3x) can be configured with ethtool to enable
receiving and transmitting pause frames for ice. When transmit is enabled,
pause frames are generated when the receive packet buffer crosses a predefined
threshold. When receive is enabled, the transmit unit will halt for the time
delay specified when a pause frame is received.

NOTE: You must have a flow control capable link partner.

Flow Control is disabled by default.

Use ethtool to change the flow control settings.

To enable or disable Rx or Tx Flow Control::

  # ethtool -A <ethX> rx <on|off> tx <on|off>

Note: This command only enables or disables Flow Control if auto-negotiation is
disabled. If auto-negotiation is enabled, this command changes the parameters
used for auto-negotiation with the link partner.

Note: Flow Control auto-negotiation is part of link auto-negotiation. Depending
on your device, you may not be able to change the auto-negotiation setting.

NOTE:

- The ice driver requires flow control on both the port and link partner. If
  flow control is disabled on one of the sides, the port may appear to hang on
  heavy traffic.
- You may encounter issues with link-level flow control (LFC) after disabling
  DCB. The LFC status may show as enabled but traffic is not paused. To resolve
  this issue, disable and reenable LFC using ethtool::

   # ethtool -A <ethX> rx off tx off
   # ethtool -A <ethX> rx on tx on


NAPI
----
This driver supports NAPI (Rx polling mode).
For more information on NAPI, see
https://www.linuxfoundation.org/collaborate/workgroups/networking/napi


MACVLAN
-------
This driver supports MACVLAN. Kernel support for MACVLAN can be tested by
checking if the MACVLAN driver is loaded. You can run 'lsmod | grep macvlan' to
see if the MACVLAN driver is loaded or run 'modprobe macvlan' to try to load
the MACVLAN driver.

NOTE:

- In passthru mode, you can only set up one MACVLAN device. It will inherit the
  MAC address of the underlying PF (Physical Function) device.


IEEE 802.1ad (QinQ) Support
---------------------------
The IEEE 802.1ad standard, informally known as QinQ, allows for multiple VLAN
IDs within a single Ethernet frame. VLAN IDs are sometimes referred to as
"tags," and multiple VLAN IDs are thus referred to as a "tag stack." Tag stacks
allow L2 tunneling and the ability to segregate traffic within a particular
VLAN ID, among other uses.

NOTES:

- Receive checksum offloads and VLAN acceleration are not supported for 802.1ad
  (QinQ) packets.

- 0x88A8 traffic will not be received unless VLAN stripping is disabled with
  the following command::

    # ethtool -K <ethX> rxvlan off

- 0x88A8/0x8100 double VLANs cannot be used with 0x8100 or 0x8100/0x8100 VLANS
  configured on the same port. 0x88a8/0x8100 traffic will not be received if
  0x8100 VLANs are configured.

- The VF can only transmit 0x88A8/0x8100 (i.e., 802.1ad/802.1Q) traffic if:

    1) The VF is not assigned a port VLAN.
    2) spoofchk is disabled from the PF. If you enable spoofchk, the VF will
       not transmit 0x88A8/0x8100 traffic.

- The VF may not receive all network traffic based on the Inner VLAN header
  when VF true promiscuous mode (vf-true-promisc-support) and double VLANs are
  enabled in SR-IOV mode.

The following are examples of how to configure 802.1ad (QinQ)::

  # ip link add link eth0 eth0.24 type vlan proto 802.1ad id 24
  # ip link add link eth0.24 eth0.24.371 type vlan proto 802.1Q id 371

  Where "24" and "371" are example VLAN IDs.


Tunnel/Overlay Stateless Offloads
---------------------------------
Supported tunnels and overlays include VXLAN, GENEVE, and others depending on
hardware and software configuration. Stateless offloads are enabled by default.

To view the current state of all offloads::

  # ethtool -k <ethX>


UDP Segmentation Offload
------------------------
Allows the adapter to offload transmit segmentation of UDP packets with
payloads up to 64K into valid Ethernet frames. Because the adapter hardware is
able to complete data segmentation much faster than operating system software,
this feature may improve transmission performance.
In addition, the adapter may use fewer CPU resources.

NOTE:

- The application sending UDP packets must support UDP segmentation offload.

To enable/disable UDP Segmentation Offload, issue the following command::

  # ethtool -K <ethX> tx-udp-segmentation [off|on]

GNSS module
-----------
Allows user to read messages from the GNSS module and write supported commands.
If the module is physically present, driver creates 2 TTYs for each supported
device in /dev, ttyGNSS_<device>:<function>_0 and _1. First one (_0) is RW and
the second one is RO.
The protocol of write commands is dependent on the GNSS module as the driver
writes raw bytes from the TTY to the GNSS i2c. Please refer to the module
documentation for details.

Performance Optimization
========================
Driver defaults are meant to fit a wide variety of workloads, but if further
optimization is required, we recommend experimenting with the following
settings.


Rx Descriptor Ring Size
-----------------------
To reduce the number of Rx packet discards, increase the number of Rx
descriptors for each Rx ring using ethtool.

  Check if the interface is dropping Rx packets due to buffers being full
  (rx_dropped.nic can mean that there is no PCIe bandwidth)::

    # ethtool -S <ethX> | grep "rx_dropped"

  If the previous command shows drops on queues, it may help to increase
  the number of descriptors using 'ethtool -G'::

    # ethtool -G <ethX> rx <N>
    Where <N> is the desired number of ring entries/descriptors

  This can provide temporary buffering for issues that create latency while
  the CPUs process descriptors.


Interrupt Rate Limiting
-----------------------
This driver supports an adaptive interrupt throttle rate (ITR) mechanism that
is tuned for general workloads. The user can customize the interrupt rate
control for specific workloads, via ethtool, adjusting the number of
microseconds between interrupts.

To set the interrupt rate manually, you must disable adaptive mode::

  # ethtool -C <ethX> adaptive-rx off adaptive-tx off

For lower CPU utilization:

  Disable adaptive ITR and lower Rx and Tx interrupts. The examples below
  affect every queue of the specified interface.

  Setting rx-usecs and tx-usecs to 80 will limit interrupts to about
  12,500 interrupts per second per queue::

    # ethtool -C <ethX> adaptive-rx off adaptive-tx off rx-usecs 80 tx-usecs 80

For reduced latency:

  Disable adaptive ITR and ITR by setting rx-usecs and tx-usecs to 0
  using ethtool::

    # ethtool -C <ethX> adaptive-rx off adaptive-tx off rx-usecs 0 tx-usecs 0

Per-queue interrupt rate settings:

  The following examples are for queues 1 and 3, but you can adjust other
  queues.

  To disable Rx adaptive ITR and set static Rx ITR to 10 microseconds or
  about 100,000 interrupts/second, for queues 1 and 3::

    # ethtool --per-queue <ethX> queue_mask 0xa --coalesce adaptive-rx off
    rx-usecs 10

  To show the current coalesce settings for queues 1 and 3::

    # ethtool --per-queue <ethX> queue_mask 0xa --show-coalesce

Bounding interrupt rates using rx-usecs-high:

  :Valid Range: 0-236 (0=no limit)

   The range of 0-236 microseconds provides an effective range of 4,237 to
   250,000 interrupts per second. The value of rx-usecs-high can be set
   independently of rx-usecs and tx-usecs in the same ethtool command, and is
   also independent of the adaptive interrupt moderation algorithm. The
   underlying hardware supports granularity in 4-microsecond intervals, so
   adjacent values may result in the same interrupt rate.

  The following command would disable adaptive interrupt moderation, and allow
  a maximum of 5 microseconds before indicating a receive or transmit was
  complete. However, instead of resulting in as many as 200,000 interrupts per
  second, it limits total interrupts per second to 50,000 via the rx-usecs-high
  parameter.

  ::

    # ethtool -C <ethX> adaptive-rx off adaptive-tx off rx-usecs-high 20
    rx-usecs 5 tx-usecs 5


Virtualized Environments
------------------------
In addition to the other suggestions in this section, the following may be
helpful to optimize performance in VMs.

  Using the appropriate mechanism (vcpupin) in the VM, pin the CPUs to
  individual LCPUs, making sure to use a set of CPUs included in the
  device's local_cpulist: ``/sys/class/net/<ethX>/device/local_cpulist``.

  Configure as many Rx/Tx queues in the VM as available. (See the iavf driver
  documentation for the number of queues supported.) For example::

    # ethtool -L <virt_interface> rx <max> tx <max>


Support
=======
For general information, go to the Intel support website at:
https://www.intel.com/support/

or the Intel Wired Networking project hosted by Sourceforge at:
https://sourceforge.net/projects/e1000

If an issue is identified with the released source code on a supported kernel
with a supported adapter, email the specific information related to the issue
to e1000-devel@lists.sf.net.


Trademarks
==========
Intel is a trademark or registered trademark of Intel Corporation or its
subsidiaries in the United States and/or other countries.

* Other names and brands may be claimed as the property of others.