summaryrefslogtreecommitdiffstats
path: root/src/collectors/charts.d.plugin/apcupsd/metadata.yaml
diff options
context:
space:
mode:
authorDaniel Baumann <daniel.baumann@progress-linux.org>2024-05-05 12:08:03 +0000
committerDaniel Baumann <daniel.baumann@progress-linux.org>2024-05-05 12:08:18 +0000
commit5da14042f70711ea5cf66e034699730335462f66 (patch)
tree0f6354ccac934ed87a2d555f45be4c831cf92f4a /src/collectors/charts.d.plugin/apcupsd/metadata.yaml
parentReleasing debian version 1.44.3-2. (diff)
downloadnetdata-5da14042f70711ea5cf66e034699730335462f66.tar.xz
netdata-5da14042f70711ea5cf66e034699730335462f66.zip
Merging upstream version 1.45.3+dfsg.
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'src/collectors/charts.d.plugin/apcupsd/metadata.yaml')
-rw-r--r--src/collectors/charts.d.plugin/apcupsd/metadata.yaml256
1 files changed, 256 insertions, 0 deletions
diff --git a/src/collectors/charts.d.plugin/apcupsd/metadata.yaml b/src/collectors/charts.d.plugin/apcupsd/metadata.yaml
new file mode 100644
index 000000000..0af9c98e6
--- /dev/null
+++ b/src/collectors/charts.d.plugin/apcupsd/metadata.yaml
@@ -0,0 +1,256 @@
+plugin_name: charts.d.plugin
+modules:
+ - meta:
+ plugin_name: charts.d.plugin
+ module_name: apcupsd
+ monitored_instance:
+ name: APC UPS
+ link: "https://www.apc.com"
+ categories:
+ - data-collection.ups
+ icon_filename: "apc.svg"
+ related_resources:
+ integrations:
+ list: []
+ info_provided_to_referring_integrations:
+ description: ""
+ keywords:
+ - ups
+ - apc
+ - power
+ - supply
+ - battery
+ - apcupsd
+ most_popular: false
+ overview:
+ data_collection:
+ metrics_description: "Monitor APC UPS performance with Netdata for optimal uninterruptible power supply operations. Enhance your power supply reliability with real-time APC UPS metrics."
+ method_description: "The collector uses the `apcaccess` tool to contact the `apcupsd` daemon and get the APC UPS statistics."
+ supported_platforms:
+ include: []
+ exclude: []
+ multi_instance: false
+ additional_permissions:
+ description: ""
+ default_behavior:
+ auto_detection:
+ description: "By default, with no configuration provided, the collector will try to contact 127.0.0.1:3551 with using the `apcaccess` utility."
+ limits:
+ description: ""
+ performance_impact:
+ description: ""
+ setup:
+ prerequisites:
+ list:
+ - title: "Install charts.d plugin"
+ description: |
+ If [using our official native DEB/RPM packages](https://github.com/netdata/netdata/blob/master/packaging/installer/UPDATE.md#determine-which-installation-method-you-used), make sure `netdata-plugin-chartsd` is installed.
+ - title: "Required software"
+ description: "Make sure the `apcaccess` and `apcupsd` are installed and running."
+ configuration:
+ file:
+ name: charts.d/apcupsd.conf
+ options:
+ description: |
+ The config file is sourced by the charts.d plugin. It's a standard bash file.
+
+ The following collapsed table contains all the options that can be configured for the apcupsd collector.
+ folding:
+ title: "Config options"
+ enabled: true
+ list:
+ - name: apcupsd_sources
+ description: This is an array of apcupsd sources. You can have multiple entries there. Please refer to the example below on how to set it.
+ default_value: "127.0.0.1:3551"
+ required: false
+ - name: apcupsd_timeout
+ description: How long to wait for apcupsd to respond.
+ default_value: 3
+ required: false
+ - name: apcupsd_update_every
+ description: The data collection frequency. If unset, will inherit the netdata update frequency.
+ default_value: 1
+ required: false
+ - name: apcupsd_priority
+ description: The charts priority on the dashboard.
+ default_value: 90000
+ required: false
+ - name: apcupsd_retries
+ description: The number of retries to do in case of failure before disabling the collector.
+ default_value: 10
+ required: false
+ examples:
+ folding:
+ enabled: false
+ title: "Config"
+ list:
+ - name: Multiple apcupsd sources
+ description: Specify a multiple apcupsd sources along with a custom update interval
+ config: |
+ # add all your APC UPSes in this array - uncomment it too
+ declare -A apcupsd_sources=(
+ ["local"]="127.0.0.1:3551",
+ ["remote"]="1.2.3.4:3551"
+ )
+
+ # how long to wait for apcupsd to respond
+ #apcupsd_timeout=3
+
+ # the data collection frequency
+ # if unset, will inherit the netdata update frequency
+ apcupsd_update_every=5
+
+ # the charts priority on the dashboard
+ #apcupsd_priority=90000
+
+ # the number of retries to do in case of failure
+ # before disabling the module
+ #apcupsd_retries=10
+ troubleshooting:
+ problems:
+ list: []
+ alerts:
+ - name: apcupsd_ups_charge
+ link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf
+ metric: apcupsd.charge
+ info: average UPS charge over the last minute
+ os: "*"
+ - name: apcupsd_10min_ups_load
+ link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf
+ metric: apcupsd.load
+ info: average UPS load over the last 10 minutes
+ os: "*"
+ - name: apcupsd_last_collected_secs
+ link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf
+ metric: apcupsd.load
+ info: number of seconds since the last successful data collection
+ - name: apcupsd_selftest_warning
+ link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf
+ metric: apcupsd.selftest
+ info: self-test failed due to insufficient battery capacity or due to overload.
+ - name: apcupsd_status_onbatt
+ link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf
+ metric: apcupsd.status
+ info: APC UPS has switched to battery power because the input power has failed
+ - name: apcupsd_status_overload
+ link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf
+ metric: apcupsd.status
+ info: APC UPS is overloaded and cannot supply enough power to the load
+ - name: apcupsd_status_lowbatt
+ link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf
+ metric: apcupsd.status
+ info: APC UPS battery is low and needs to be recharged
+ - name: apcupsd_status_replacebatt
+ link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf
+ metric: apcupsd.status
+ info: APC UPS battery has reached the end of its lifespan and needs to be replaced
+ - name: apcupsd_status_nobatt
+ link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf
+ metric: apcupsd.status
+ info: APC UPS has no battery
+ - name: apcupsd_status_commlost
+ link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf
+ metric: apcupsd.status
+ info: APC UPS communication link is lost
+ metrics:
+ folding:
+ title: Metrics
+ enabled: false
+ description: ""
+ availability: []
+ scopes:
+ - name: ups
+ description: "Metrics related to UPS. Each UPS provides its own set of the following metrics."
+ labels: []
+ metrics:
+ - name: apcupsd.charge
+ description: UPS Charge
+ unit: "percentage"
+ chart_type: area
+ dimensions:
+ - name: charge
+ - name: apcupsd.battery.voltage
+ description: UPS Battery Voltage
+ unit: "Volts"
+ chart_type: line
+ dimensions:
+ - name: voltage
+ - name: nominal
+ - name: apcupsd.input.voltage
+ description: UPS Input Voltage
+ unit: "Volts"
+ chart_type: line
+ dimensions:
+ - name: voltage
+ - name: min
+ - name: max
+ - name: apcupsd.output.voltage
+ description: UPS Output Voltage
+ unit: "Volts"
+ chart_type: line
+ dimensions:
+ - name: absolute
+ - name: nominal
+ - name: apcupsd.input.frequency
+ description: UPS Input Voltage
+ unit: "Hz"
+ chart_type: line
+ dimensions:
+ - name: frequency
+ - name: apcupsd.load
+ description: UPS Load
+ unit: "percentage"
+ chart_type: area
+ dimensions:
+ - name: load
+ - name: apcupsd.load_usage
+ description: UPS Load Usage
+ unit: "Watts"
+ chart_type: area
+ dimensions:
+ - name: load
+ - name: apcupsd.temperature
+ description: UPS Temperature
+ unit: "Celsius"
+ chart_type: line
+ dimensions:
+ - name: temp
+ - name: apcupsd.time
+ description: UPS Time Remaining
+ unit: "Minutes"
+ chart_type: area
+ dimensions:
+ - name: time
+ - name: apcupsd.online
+ description: UPS ONLINE flag
+ unit: "boolean"
+ chart_type: line
+ dimensions:
+ - name: online
+ - name: apcupsd.selftest
+ description: UPS Self-Test status
+ unit: status
+ chart_type: line
+ dimensions:
+ - name: OK
+ - name: NO
+ - name: BT
+ - name: NG
+ - name: apcupsd.status
+ description: UPS Status
+ unit: status
+ chart_type: line
+ dimensions:
+ - name: ONLINE
+ - name: ONBATT
+ - name: OVERLOAD
+ - name: LOWBATT
+ - name: REPLACEBATT
+ - name: NOBATT
+ - name: SLAVE
+ - name: SLAVEDOWN
+ - name: COMMLOST
+ - name: CAL
+ - name: TRIM
+ - name: BOOST
+ - name: SHUTTING_DOWN