diff --git a/collectors/charts.d.plugin/apcupsd/integrations/apc_ups.md b/collectors/charts.d.plugin/apcupsd/integrations/apc_ups.md
deleted file mode 100644
index a5c1f9613..000000000
--- a/collectors/charts.d.plugin/apcupsd/integrations/apc_ups.md
+++ /dev/null
@@ -1,203 +0,0 @@
-<!--startmeta
-custom_edit_url: "https://github.com/netdata/netdata/edit/master/collectors/charts.d.plugin/apcupsd/README.md"
-meta_yaml: "https://github.com/netdata/netdata/edit/master/collectors/charts.d.plugin/apcupsd/metadata.yaml"
-sidebar_label: "APC UPS"
-learn_status: "Published"
-learn_rel_path: "Data Collection/UPS"
-most_popular: False
-message: "DO NOT EDIT THIS FILE DIRECTLY, IT IS GENERATED BY THE COLLECTOR'S metadata.yaml FILE"
-endmeta-->
-
-# APC UPS
-
-
-<img src="https://netdata.cloud/img/apc.svg" width="150"/>
-
-
-Plugin: charts.d.plugin
-Module: apcupsd
-
-<img src="https://img.shields.io/badge/maintained%20by-Netdata-%2300ab44" />
-
-## Overview
-
-Monitor APC UPS performance with Netdata for optimal uninterruptible power supply operations. Enhance your power supply reliability with real-time APC UPS metrics.
-
-The collector uses the `apcaccess` tool to contact the `apcupsd` daemon and get the APC UPS statistics.
-
-This collector is supported on all platforms.
-
-This collector only supports collecting metrics from a single instance of this integration.
-
-
-### Default Behavior
-
-#### Auto-Detection
-
-By default, with no configuration provided, the collector will try to contact 127.0.0.1:3551 with using the `apcaccess` utility.
-
-#### Limits
-
-The default configuration for this integration does not impose any limits on data collection.
-
-#### Performance Impact
-
-The default configuration for this integration is not expected to impose a significant performance impact on the system.
-
-
-## Metrics
-
-Metrics grouped by *scope*.
-
-The scope defines the instance that the metric belongs to. An instance is uniquely identified by a set of labels.
-
-
-
-### Per ups
-
-Metrics related to UPS. Each UPS provides its own set of the following metrics.
-
-This scope has no labels.
-
-Metrics:
-
-| Metric | Dimensions | Unit |
-|:------|:----------|:----|
-| apcupsd.charge | charge | percentage |
-| apcupsd.battery.voltage | voltage, nominal | Volts |
-| apcupsd.input.voltage | voltage, min, max | Volts |
-| apcupsd.output.voltage | absolute, nominal | Volts |
-| apcupsd.input.frequency | frequency | Hz |
-| apcupsd.load | load | percentage |
-| apcupsd.load_usage | load | Watts |
-| apcupsd.temperature | temp | Celsius |
-| apcupsd.time | time | Minutes |
-| apcupsd.online | online | boolean |
-| apcupsd.selftest | OK, NO, BT, NG | status |
-| apcupsd.status | ONLINE, ONBATT, OVERLOAD, LOWBATT, REPLACEBATT, NOBATT, SLAVE, SLAVEDOWN, COMMLOST, CAL, TRIM, BOOST, SHUTTING_DOWN | status |
-
-
-
-## Alerts
-
-
-The following alerts are available:
-
-| Alert name | On metric | Description |
-|:------------|:----------|:------------|
-| [ apcupsd_ups_charge ](https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf) | apcupsd.charge | average UPS charge over the last minute |
-| [ apcupsd_10min_ups_load ](https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf) | apcupsd.load | average UPS load over the last 10 minutes |
-| [ apcupsd_last_collected_secs ](https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf) | apcupsd.load | number of seconds since the last successful data collection |
-| [ apcupsd_selftest_warning ](https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf) | apcupsd.selftest | self-test failed due to insufficient battery capacity or due to overload. |
-| [ apcupsd_status_onbatt ](https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf) | apcupsd.status | APC UPS has switched to battery power because the input power has failed |
-| [ apcupsd_status_overload ](https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf) | apcupsd.status | APC UPS is overloaded and cannot supply enough power to the load |
-| [ apcupsd_status_lowbatt ](https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf) | apcupsd.status | APC UPS battery is low and needs to be recharged |
-| [ apcupsd_status_replacebatt ](https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf) | apcupsd.status | APC UPS battery has reached the end of its lifespan and needs to be replaced |
-| [ apcupsd_status_nobatt ](https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf) | apcupsd.status | APC UPS has no battery |
-| [ apcupsd_status_commlost ](https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf) | apcupsd.status | APC UPS communication link is lost |
-
-
-## Setup
-
-### Prerequisites
-
-#### Install charts.d plugin
-
-If [using our official native DEB/RPM packages](https://github.com/netdata/netdata/blob/master/packaging/installer/UPDATE.md#determine-which-installation-method-you-used), make sure `netdata-plugin-chartsd` is installed.
-
-
-#### Required software
-
-Make sure the `apcaccess` and `apcupsd` are installed and running.
-
-
-### Configuration
-
-#### File
-
-The configuration file name for this integration is `charts.d/apcupsd.conf`.
-
-
-You can edit the configuration file using the `edit-config` script from the
-Netdata [config directory](https://github.com/netdata/netdata/blob/master/docs/configure/nodes.md#the-netdata-config-directory).
-
-```bash
-cd /etc/netdata 2>/dev/null || cd /opt/netdata/etc/netdata
-sudo ./edit-config charts.d/apcupsd.conf
-```
-#### Options
-
-The config file is sourced by the charts.d plugin. It's a standard bash file.
-
-The following collapsed table contains all the options that can be configured for the apcupsd collector.
-
-
-<details><summary>Config options</summary>
-
-| Name | Description | Default | Required |
-|:----|:-----------|:-------|:--------:|
-| apcupsd_sources | This is an array of apcupsd sources. You can have multiple entries there. Please refer to the example below on how to set it. | 127.0.0.1:3551 | no |
-| apcupsd_timeout | How long to wait for apcupsd to respond. | 3 | no |
-| apcupsd_update_every | The data collection frequency. If unset, will inherit the netdata update frequency. | 1 | no |
-| apcupsd_priority | The charts priority on the dashboard. | 90000 | no |
-| apcupsd_retries | The number of retries to do in case of failure before disabling the collector. | 10 | no |
-
-</details>
-
-#### Examples
-
-##### Multiple apcupsd sources
-
-Specify a multiple apcupsd sources along with a custom update interval
-
-```yaml
-# add all your APC UPSes in this array - uncomment it too
-declare -A apcupsd_sources=(
- ["local"]="127.0.0.1:3551",
- ["remote"]="1.2.3.4:3551"
-)
-
-# how long to wait for apcupsd to respond
-#apcupsd_timeout=3
-
-# the data collection frequency
-# if unset, will inherit the netdata update frequency
-apcupsd_update_every=5
-
-# the charts priority on the dashboard
-#apcupsd_priority=90000
-
-# the number of retries to do in case of failure
-# before disabling the module
-#apcupsd_retries=10
-
-```
-
-
-## Troubleshooting
-
-### Debug Mode
-
-To troubleshoot issues with the `apcupsd` collector, run the `charts.d.plugin` with the debug option enabled. The output
-should give you clues as to why the collector isn't working.
-
-- Navigate to the `plugins.d` directory, usually at `/usr/libexec/netdata/plugins.d/`. If that's not the case on
- your system, open `netdata.conf` and look for the `plugins` setting under `[directories]`.
-
- ```bash
- cd /usr/libexec/netdata/plugins.d/
- ```
-
-- Switch to the `netdata` user.
-
- ```bash
- sudo -u netdata -s
- ```
-
-- Run the `charts.d.plugin` to debug the collector:
-
- ```bash
- ./charts.d.plugin debug 1 apcupsd
- ```
-
-