-rw-r--r--collectors/charts.d.plugin/nut/metadata.yaml222
1 files changed, 0 insertions, 222 deletions
diff --git a/collectors/charts.d.plugin/nut/metadata.yaml b/collectors/charts.d.plugin/nut/metadata.yaml
deleted file mode 100644
index ed3ffebf7..000000000
--- a/collectors/charts.d.plugin/nut/metadata.yaml
+++ /dev/null
@@ -1,222 +0,0 @@
-plugin_name: charts.d.plugin
-modules:
- - meta:
- plugin_name: charts.d.plugin
- module_name: nut
- monitored_instance:
- name: Network UPS Tools (NUT)
- link: ''
- categories:
- - data-collection.ups
- icon_filename: 'plug-circle-bolt.svg'
- related_resources:
- integrations:
- list: []
- info_provided_to_referring_integrations:
- description: ''
- keywords:
- - nut
- - network ups tools
- - ups
- - pdu
- most_popular: false
- overview:
- data_collection:
- metrics_description: 'Examine UPS/PDU metrics with Netdata for insights into power device performance. Improve your power device performance with comprehensive dashboards and anomaly detection.'
- method_description: 'This collector uses the `nut` (Network UPS Tools) to query statistics for multiple UPS devices.'
- supported_platforms:
- include: []
- exclude: []
- multi_instance: true
- additional_permissions:
- description: ''
- default_behavior:
- auto_detection:
- description: ''
- limits:
- description: ''
- performance_impact:
- description: ''
- setup:
- prerequisites:
- list:
- - title: "Install charts.d plugin"
- description: |
- If [using our official native DEB/RPM packages](https://github.com/netdata/netdata/blob/master/packaging/installer/UPDATE.md#determine-which-installation-method-you-used), make sure `netdata-plugin-chartsd` is installed.
- - title: "Required software"
- description: "Make sure the Network UPS Tools (`nut`) is installed and can detect your UPS devices."
- configuration:
- file:
- name: charts.d/nut.conf
- options:
- description: |
- The config file is sourced by the charts.d plugin. It's a standard bash file.
-
- The following collapsed table contains all the options that can be configured for the nut collector.
- folding:
- title: "Config options"
- enabled: true
- list:
- - name: nut_ups
- description: A space separated list of UPS names. If empty, the list returned by `upsc -l` will be used.
- default_value: ""
- required: false
- - name: nut_names
- description: Each line represents an alias for one UPS. If empty, the FQDN will be used.
- default_value: ""
- required: false
- - name: nut_timeout
- description: How long to wait for nut to respond.
- default_value: 2
- required: false
- - name: nut_clients_chart
- description: Set this to 1 to enable another chart showing the number of UPS clients connected to `upsd`.
- default_value: 1
- required: false
- - name: nut_update_every
- description: The data collection frequency. If unset, will inherit the netdata update frequency.
- default_value: 2
- required: false
- - name: nut_priority
- description: The charts priority on the dashboard
- default_value: 90000
- required: false
- - name: nut_retries
- description: The number of retries to do in case of failure before disabling the collector.
- default_value: 10
- required: false
- examples:
- folding:
- enabled: true
- title: "Config"
- list:
- - name: Provide names to UPS devices
- description: Map aliases to UPS devices
- config: |
- # a space separated list of UPS names
- # if empty, the list returned by 'upsc -l' will be used
- #nut_ups=
-
- # each line represents an alias for one UPS
- # if empty, the FQDN will be used
- nut_names["XXXXXX"]="UPS-office"
- nut_names["YYYYYY"]="UPS-rack"
-
- # how much time in seconds, to wait for nut to respond
- #nut_timeout=2
-
- # set this to 1, to enable another chart showing the number
- # of UPS clients connected to upsd
- #nut_clients_chart=1
-
- # the data collection frequency
- # if unset, will inherit the netdata update frequency
- #nut_update_every=2
-
- # the charts priority on the dashboard
- #nut_priority=90000
-
- # the number of retries to do in case of failure
- # before disabling the module
- #nut_retries=10
- troubleshooting:
- problems:
- list: []
- alerts:
- - name: nut_ups_charge
- link: https://github.com/netdata/netdata/blob/master/health/health.d/nut.conf
- metric: nut.charge
- info: average UPS charge over the last minute
- os: "*"
- - name: nut_10min_ups_load
- link: https://github.com/netdata/netdata/blob/master/health/health.d/nut.conf
- metric: nut.load
- info: average UPS load over the last 10 minutes
- os: "*"
- - name: nut_last_collected_secs
- link: https://github.com/netdata/netdata/blob/master/health/health.d/nut.conf
- metric: nut.load
- info: number of seconds since the last successful data collection
- metrics:
- folding:
- title: Metrics
- enabled: false
- description: ""
- availability: []
- scopes:
- - name: ups
- description: "Metrics related to UPS. Each UPS provides its own set of the following metrics."
- labels: []
- metrics:
- - name: nut.charge
- description: UPS Charge
- unit: "percentage"
- chart_type: area
- dimensions:
- - name: charge
- - name: nut.runtime
- description: UPS Runtime
- unit: "seconds"
- chart_type: line
- dimensions:
- - name: runtime
- - name: nut.battery.voltage
- description: UPS Battery Voltage
- unit: "Volts"
- chart_type: line
- dimensions:
- - name: voltage
- - name: high
- - name: low
- - name: nominal
- - name: nut.input.voltage
- description: UPS Input Voltage
- unit: "Volts"
- chart_type: line
- dimensions:
- - name: voltage
- - name: fault
- - name: nominal
- - name: nut.input.current
- description: UPS Input Current
- unit: "Ampere"
- chart_type: line
- dimensions:
- - name: nominal
- - name: nut.input.frequency
- description: UPS Input Frequency
- unit: "Hz"
- chart_type: line
- dimensions:
- - name: frequency
- - name: nominal
- - name: nut.output.voltage
- description: UPS Output Voltage
- unit: "Volts"
- chart_type: line
- dimensions:
- - name: voltage
- - name: nut.load
- description: UPS Load
- unit: "percentage"
- chart_type: area
- dimensions:
- - name: load
- - name: nut.load_usage
- description: UPS Load Usage
- unit: "Watts"
- chart_type: area
- dimensions:
- - name: load_usage
- - name: nut.temperature
- description: UPS Temperature
- unit: "temperature"
- chart_type: line
- dimensions:
- - name: temp
- - name: nut.clients
- description: UPS Connected Clients
- unit: "clients"
- chart_type: area
- dimensions:
- - name: clients