summaryrefslogtreecommitdiffstats
path: root/collectors/charts.d.plugin/sensors/integrations/linux_sensors_sysfs.md
diff options
context:
space:
mode:
Diffstat (limited to 'collectors/charts.d.plugin/sensors/integrations/linux_sensors_sysfs.md')
-rw-r--r--collectors/charts.d.plugin/sensors/integrations/linux_sensors_sysfs.md201
1 files changed, 0 insertions, 201 deletions
diff --git a/collectors/charts.d.plugin/sensors/integrations/linux_sensors_sysfs.md b/collectors/charts.d.plugin/sensors/integrations/linux_sensors_sysfs.md
deleted file mode 100644
index 130352f61..000000000
--- a/collectors/charts.d.plugin/sensors/integrations/linux_sensors_sysfs.md
+++ /dev/null
@@ -1,201 +0,0 @@
-<!--startmeta
-custom_edit_url: "https://github.com/netdata/netdata/edit/master/collectors/charts.d.plugin/sensors/README.md"
-meta_yaml: "https://github.com/netdata/netdata/edit/master/collectors/charts.d.plugin/sensors/metadata.yaml"
-sidebar_label: "Linux Sensors (sysfs)"
-learn_status: "Published"
-learn_rel_path: "Data Collection/Hardware Devices and Sensors"
-most_popular: False
-message: "DO NOT EDIT THIS FILE DIRECTLY, IT IS GENERATED BY THE COLLECTOR'S metadata.yaml FILE"
-endmeta-->
-
-# Linux Sensors (sysfs)
-
-
-<img src="https://netdata.cloud/img/microchip.svg" width="150"/>
-
-
-Plugin: charts.d.plugin
-Module: sensors
-
-<img src="https://img.shields.io/badge/maintained%20by-Netdata-%2300ab44" />
-
-## Overview
-
-Use this collector when `lm-sensors` doesn't work on your device (e.g. for RPi temperatures).
-For all other cases use the [Python collector](https://github.com/netdata/netdata/blob/master/collectors/python.d.plugin/sensors), which supports multiple jobs, is more efficient and performs calculations on top of the kernel provided values."
-
-
-It will provide charts for all configured system sensors, by reading sensors directly from the kernel.
-The values graphed are the raw hardware values of the sensors.
-
-
-This collector is only supported on the following platforms:
-
-- Linux
-
-This collector supports collecting metrics from multiple instances of this integration, including remote instances.
-
-
-### Default Behavior
-
-#### Auto-Detection
-
-By default, the collector will try to read entries under `/sys/devices`
-
-#### Limits
-
-The default configuration for this integration does not impose any limits on data collection.
-
-#### Performance Impact
-
-The default configuration for this integration is not expected to impose a significant performance impact on the system.
-
-
-## Metrics
-
-Metrics grouped by *scope*.
-
-The scope defines the instance that the metric belongs to. An instance is uniquely identified by a set of labels.
-
-
-
-### Per sensor chip
-
-Metrics related to sensor chips. Each chip provides its own set of the following metrics.
-
-This scope has no labels.
-
-Metrics:
-
-| Metric | Dimensions | Unit |
-|:------|:----------|:----|
-| sensors.temp | {filename} | Celsius |
-| sensors.volt | {filename} | Volts |
-| sensors.curr | {filename} | Ampere |
-| sensors.power | {filename} | Watt |
-| sensors.fans | {filename} | Rotations / Minute |
-| sensors.energy | {filename} | Joule |
-| sensors.humidity | {filename} | Percent |
-
-
-
-## Alerts
-
-There are no alerts configured by default for this integration.
-
-
-## Setup
-
-### Prerequisites
-
-#### Install charts.d plugin
-
-If [using our official native DEB/RPM packages](https://github.com/netdata/netdata/blob/master/packaging/installer/UPDATE.md#determine-which-installation-method-you-used), make sure `netdata-plugin-chartsd` is installed.
-
-
-#### Enable the sensors collector
-
-The `sensors` collector is disabled by default. To enable it, use `edit-config` from the Netdata [config directory](https://github.com/netdata/netdata/blob/master/docs/configure/nodes.md), which is typically at `/etc/netdata`, to edit the `charts.d.conf` file.
-
-```bash
-cd /etc/netdata # Replace this path with your Netdata config directory, if different
-sudo ./edit-config charts.d.conf
-```
-
-Change the value of the `sensors` setting to `force` and uncomment the line. Save the file and restart the Netdata Agent with `sudo systemctl restart netdata`, or the [appropriate method](https://github.com/netdata/netdata/blob/master/docs/configure/start-stop-restart.md) for your system.
-
-
-
-### Configuration
-
-#### File
-
-The configuration file name for this integration is `charts.d/sensors.conf`.
-
-
-You can edit the configuration file using the `edit-config` script from the
-Netdata [config directory](https://github.com/netdata/netdata/blob/master/docs/configure/nodes.md#the-netdata-config-directory).
-
-```bash
-cd /etc/netdata 2>/dev/null || cd /opt/netdata/etc/netdata
-sudo ./edit-config charts.d/sensors.conf
-```
-#### Options
-
-The config file is sourced by the charts.d plugin. It's a standard bash file.
-
-The following collapsed table contains all the options that can be configured for the sensors collector.
-
-
-<details><summary>Config options</summary>
-
-| Name | Description | Default | Required |
-|:----|:-----------|:-------|:--------:|
-| sensors_sys_dir | The directory the kernel exposes sensor data. | /sys/devices | no |
-| sensors_sys_depth | How deep in the tree to check for sensor data. | 10 | no |
-| sensors_source_update | If set to 1, the script will overwrite internal script functions with code generated ones. | 1 | no |
-| sensors_update_every | The data collection frequency. If unset, will inherit the netdata update frequency. | 1 | no |
-| sensors_priority | The charts priority on the dashboard. | 90000 | no |
-| sensors_retries | The number of retries to do in case of failure before disabling the collector. | 10 | no |
-
-</details>
-
-#### Examples
-
-##### Set sensors path depth
-
-Set a different sensors path depth
-
-```yaml
-# the directory the kernel keeps sensor data
-#sensors_sys_dir="/sys/devices"
-
-# how deep in the tree to check for sensor data
-sensors_sys_depth=5
-
-# if set to 1, the script will overwrite internal
-# script functions with code generated ones
-# leave to 1, is faster
-#sensors_source_update=1
-
-# the data collection frequency
-# if unset, will inherit the netdata update frequency
-#sensors_update_every=
-
-# the charts priority on the dashboard
-#sensors_priority=90000
-
-# the number of retries to do in case of failure
-# before disabling the module
-#sensors_retries=10
-
-```
-
-
-## Troubleshooting
-
-### Debug Mode
-
-To troubleshoot issues with the `sensors` collector, run the `charts.d.plugin` with the debug option enabled. The output
-should give you clues as to why the collector isn't working.
-
-- Navigate to the `plugins.d` directory, usually at `/usr/libexec/netdata/plugins.d/`. If that's not the case on
- your system, open `netdata.conf` and look for the `plugins` setting under `[directories]`.
-
- ```bash
- cd /usr/libexec/netdata/plugins.d/
- ```
-
-- Switch to the `netdata` user.
-
- ```bash
- sudo -u netdata -s
- ```
-
-- Run the `charts.d.plugin` to debug the collector:
-
- ```bash
- ./charts.d.plugin debug 1 sensors
- ```
-
-