diff options
Diffstat (limited to 'collectors/charts.d.plugin/sensors/metadata.yaml')
-rw-r--r-- | collectors/charts.d.plugin/sensors/metadata.yaml | 182 |
1 files changed, 0 insertions, 182 deletions
diff --git a/collectors/charts.d.plugin/sensors/metadata.yaml b/collectors/charts.d.plugin/sensors/metadata.yaml deleted file mode 100644 index 47f6f404..00000000 --- a/collectors/charts.d.plugin/sensors/metadata.yaml +++ /dev/null @@ -1,182 +0,0 @@ -plugin_name: charts.d.plugin -modules: - - meta: - plugin_name: charts.d.plugin - module_name: sensors - monitored_instance: - name: Linux Sensors (sysfs) - link: "https://www.kernel.org/doc/Documentation/hwmon/sysfs-interface" - categories: - - data-collection.hardware-devices-and-sensors - icon_filename: "microchip.svg" - related_resources: - integrations: - list: [] - info_provided_to_referring_integrations: - description: "" - keywords: - - sensors - - sysfs - - hwmon - - rpi - - raspberry pi - most_popular: false - overview: - data_collection: - metrics_description: | - Use this collector when `lm-sensors` doesn't work on your device (e.g. for RPi temperatures). - For all other cases use the [Python collector](https://github.com/netdata/netdata/blob/master/collectors/python.d.plugin/sensors), which supports multiple jobs, is more efficient and performs calculations on top of the kernel provided values." - method_description: | - It will provide charts for all configured system sensors, by reading sensors directly from the kernel. - The values graphed are the raw hardware values of the sensors. - supported_platforms: - include: [Linux] - exclude: [] - multi_instance: true - additional_permissions: - description: "" - default_behavior: - auto_detection: - description: "By default, the collector will try to read entries under `/sys/devices`" - limits: - description: "" - performance_impact: - description: "" - setup: - prerequisites: - list: - - title: "Install charts.d plugin" - description: | - If [using our official native DEB/RPM packages](https://github.com/netdata/netdata/blob/master/packaging/installer/UPDATE.md#determine-which-installation-method-you-used), make sure `netdata-plugin-chartsd` is installed. - - title: "Enable the sensors collector" - description: | - The `sensors` collector is disabled by default. To enable it, use `edit-config` from the Netdata [config directory](https://github.com/netdata/netdata/blob/master/docs/configure/nodes.md), which is typically at `/etc/netdata`, to edit the `charts.d.conf` file. - - ```bash - cd /etc/netdata # Replace this path with your Netdata config directory, if different - sudo ./edit-config charts.d.conf - ``` - - Change the value of the `sensors` setting to `force` and uncomment the line. Save the file and restart the Netdata Agent with `sudo systemctl restart netdata`, or the [appropriate method](https://github.com/netdata/netdata/blob/master/docs/configure/start-stop-restart.md) for your system. - configuration: - file: - name: charts.d/sensors.conf - options: - description: | - The config file is sourced by the charts.d plugin. It's a standard bash file. - - The following collapsed table contains all the options that can be configured for the sensors collector. - folding: - title: "Config options" - enabled: true - list: - - name: sensors_sys_dir - description: The directory the kernel exposes sensor data. - default_value: "/sys/devices" - required: false - - name: sensors_sys_depth - description: How deep in the tree to check for sensor data. - default_value: 10 - required: false - - name: sensors_source_update - description: If set to 1, the script will overwrite internal script functions with code generated ones. - default_value: 1 - required: false - - name: sensors_update_every - description: The data collection frequency. If unset, will inherit the netdata update frequency. - default_value: 1 - required: false - - name: sensors_priority - description: The charts priority on the dashboard. - default_value: 90000 - required: false - - name: sensors_retries - description: The number of retries to do in case of failure before disabling the collector. - default_value: 10 - required: false - examples: - folding: - enabled: false - title: "Config" - list: - - name: Set sensors path depth - description: Set a different sensors path depth - config: | - # the directory the kernel keeps sensor data - #sensors_sys_dir="/sys/devices" - - # how deep in the tree to check for sensor data - sensors_sys_depth=5 - - # if set to 1, the script will overwrite internal - # script functions with code generated ones - # leave to 1, is faster - #sensors_source_update=1 - - # the data collection frequency - # if unset, will inherit the netdata update frequency - #sensors_update_every= - - # the charts priority on the dashboard - #sensors_priority=90000 - - # the number of retries to do in case of failure - # before disabling the module - #sensors_retries=10 - troubleshooting: - problems: - list: [] - alerts: [] - metrics: - folding: - title: Metrics - enabled: false - description: "" - availability: [] - scopes: - - name: sensor chip - description: "Metrics related to sensor chips. Each chip provides its own set of the following metrics." - labels: [] - metrics: - - name: sensors.temp - description: Temperature - unit: "Celsius" - chart_type: line - dimensions: - - name: "{filename}" - - name: sensors.volt - description: Voltage - unit: "Volts" - chart_type: line - dimensions: - - name: "{filename}" - - name: sensors.curr - description: Current - unit: "Ampere" - chart_type: line - dimensions: - - name: "{filename}" - - name: sensors.power - description: Power - unit: "Watt" - chart_type: line - dimensions: - - name: "{filename}" - - name: sensors.fans - description: Fans Speed - unit: "Rotations / Minute" - chart_type: line - dimensions: - - name: "{filename}" - - name: sensors.energy - description: Energy - unit: "Joule" - chart_type: area - dimensions: - - name: "{filename}" - - name: sensors.humidity - description: Humidity - unit: "Percent" - chart_type: line - dimensions: - - name: "{filename}" |