summaryrefslogtreecommitdiffstats
path: root/collectors/proc.plugin/integrations/power_supply.md
diff options
context:
space:
mode:
Diffstat (limited to 'collectors/proc.plugin/integrations/power_supply.md')
-rw-r--r--collectors/proc.plugin/integrations/power_supply.md107
1 files changed, 0 insertions, 107 deletions
diff --git a/collectors/proc.plugin/integrations/power_supply.md b/collectors/proc.plugin/integrations/power_supply.md
deleted file mode 100644
index 9a474e82a..000000000
--- a/collectors/proc.plugin/integrations/power_supply.md
+++ /dev/null
@@ -1,107 +0,0 @@
-<!--startmeta
-custom_edit_url: "https://github.com/netdata/netdata/edit/master/collectors/proc.plugin/integrations/power_supply.md"
-meta_yaml: "https://github.com/netdata/netdata/edit/master/collectors/proc.plugin/metadata.yaml"
-sidebar_label: "Power Supply"
-learn_status: "Published"
-learn_rel_path: "Data Collection/Linux Systems/Power Supply"
-most_popular: False
-message: "DO NOT EDIT THIS FILE DIRECTLY, IT IS GENERATED BY THE COLLECTOR'S metadata.yaml FILE"
-endmeta-->
-
-# Power Supply
-
-
-<img src="https://netdata.cloud/img/powersupply.svg" width="150"/>
-
-
-Plugin: proc.plugin
-Module: /sys/class/power_supply
-
-<img src="https://img.shields.io/badge/maintained%20by-Netdata-%2300ab44" />
-
-## Overview
-
-This integration monitors Power supply metrics, such as battery status, AC power status and more.
-
-
-
-This collector is supported on all platforms.
-
-This collector supports collecting metrics from multiple instances of this integration, including remote instances.
-
-
-### Default Behavior
-
-#### Auto-Detection
-
-This integration doesn't support auto-detection.
-
-#### Limits
-
-The default configuration for this integration does not impose any limits on data collection.
-
-#### Performance Impact
-
-The default configuration for this integration is not expected to impose a significant performance impact on the system.
-
-
-## Metrics
-
-Metrics grouped by *scope*.
-
-The scope defines the instance that the metric belongs to. An instance is uniquely identified by a set of labels.
-
-
-
-### Per power device
-
-
-
-Labels:
-
-| Label | Description |
-|:-----------|:----------------|
-| device | TBD |
-
-Metrics:
-
-| Metric | Dimensions | Unit |
-|:------|:----------|:----|
-| powersupply.capacity | capacity | percentage |
-| powersupply.charge | empty_design, empty, now, full, full_design | Ah |
-| powersupply.energy | empty_design, empty, now, full, full_design | Wh |
-| powersupply.voltage | min_design, min, now, max, max_design | V |
-
-
-
-## Alerts
-
-
-The following alerts are available:
-
-| Alert name | On metric | Description |
-|:------------|:----------|:------------|
-| [ linux_power_supply_capacity ](https://github.com/netdata/netdata/blob/master/health/health.d/linux_power_supply.conf) | powersupply.capacity | percentage of remaining power supply capacity |
-
-
-## Setup
-
-### Prerequisites
-
-No action required.
-
-### Configuration
-
-#### File
-
-There is no configuration file.
-#### Options
-
-
-
-There are no configuration options.
-
-#### Examples
-There are no configuration examples.
-
-