@@ -0,0 +1,186 @@
+<!--startmeta
+custom_edit_url: "https://github.com/netdata/netdata/edit/master/collectors/python.d.plugin/sensors/README.md"
+meta_yaml: "https://github.com/netdata/netdata/edit/master/collectors/python.d.plugin/sensors/metadata.yaml"
+sidebar_label: "Linux Sensors (lm-sensors)"
+learn_status: "Published"
+learn_rel_path: "Data Collection/Hardware Devices and Sensors"
+message: "DO NOT EDIT THIS FILE DIRECTLY, IT IS GENERATED BY THE COLLECTOR'S metadata.yaml FILE"
+endmeta-->
+
+# Linux Sensors (lm-sensors)
+
+
+<img src="https://netdata.cloud/img/microchip.svg" width="150"/>
+
+
+Plugin: python.d.plugin
+Module: sensors
+
+<img src="https://img.shields.io/badge/maintained%20by-Netdata-%2300ab44" />
+
+## Overview
+
+Examine Linux Sensors metrics with Netdata for insights into hardware health and performance.
+
+Enhance your system's reliability with real-time hardware health insights.
+
+
+Reads system sensors information (temperature, voltage, electric current, power, etc.) via [lm-sensors](https://hwmon.wiki.kernel.org/lm_sensors).
+
+
+This collector is supported on all platforms.
+
+This collector supports collecting metrics from multiple instances of this integration, including remote instances.
+
+
+### Default Behavior
+
+#### Auto-Detection
+
+The following type of sensors are auto-detected:
+- temperature - fan - voltage - current - power - energy - humidity
+
+
+#### Limits
+
+The default configuration for this integration does not impose any limits on data collection.
+
+#### Performance Impact
+
+The default configuration for this integration is not expected to impose a significant performance impact on the system.
+
+
+## Metrics
+
+Metrics grouped by *scope*.
+
+The scope defines the instance that the metric belongs to. An instance is uniquely identified by a set of labels.
+
+
+
+### Per chip
+
+Metrics related to chips. Each chip provides a set of the following metrics, each having the chip name in the metric name as reported by `sensors -u`.
+
+
+This scope has no labels.
+
+Metrics:
+
+| Metric | Dimensions | Unit |
+|:------|:----------|:----|
+| sensors.temperature | a dimension per sensor | Celsius |
+| sensors.voltage | a dimension per sensor | Volts |
+| sensors.current | a dimension per sensor | Ampere |
+| sensors.power | a dimension per sensor | Watt |
+| sensors.fan | a dimension per sensor | Rotations/min |
+| sensors.energy | a dimension per sensor | Joule |
+| sensors.humidity | a dimension per sensor | Percent |
+
+
+
+## Alerts
+
+There are no alerts configured by default for this integration.
+
+
+## Setup
+
+### Prerequisites
+
+No action required.
+
+### Configuration
+
+#### File
+
+The configuration file name for this integration is `python.d/sensors.conf`.
+
+
+You can edit the configuration file using the `edit-config` script from the
+Netdata [config directory](https://github.com/netdata/netdata/blob/master/docs/configure/nodes.md#the-netdata-config-directory).
+
+```bash
+cd /etc/netdata 2>/dev/null || cd /opt/netdata/etc/netdata
+sudo ./edit-config python.d/sensors.conf
+```
+#### Options
+
+There are 2 sections:
+
+* Global variables
+* One or more JOBS that can define multiple different instances to monitor.
+
+The following options can be defined globally: priority, penalty, autodetection_retry, update_every, but can also be defined per JOB to override the global values.
+
+Additionally, the following collapsed table contains all the options that can be configured inside a JOB definition.
+
+Every configuration JOB starts with a `job_name` value which will appear in the dashboard, unless a `name` parameter is specified.
+
+
+<details><summary>Config options</summary>
+
+| Name | Description | Default | Required |
+|:----|:-----------|:-------|:--------:|
+| types | The types of sensors to collect. | temperature, fan, voltage, current, power, energy, humidity | True |
+| update_every | Sets the default data collection frequency. | 1 | False |
+| priority | Controls the order of charts at the netdata dashboard. | 60000 | False |
+| autodetection_retry | Sets the job re-check interval in seconds. | 0 | False |
+| penalty | Indicates whether to apply penalty to update_every in case of failures. | yes | False |
+
+</details>
+
+#### Examples
+
+##### Default
+
+Default configuration.
+
+```yaml
+types:
+ - temperature
+ - fan
+ - voltage
+ - current
+ - power
+ - energy
+ - humidity
+
+```
+
+
+## Troubleshooting
+
+### Debug Mode
+
+To troubleshoot issues with the `sensors` collector, run the `python.d.plugin` with the debug option enabled. The output
+should give you clues as to why the collector isn't working.
+
+- Navigate to the `plugins.d` directory, usually at `/usr/libexec/netdata/plugins.d/`. If that's not the case on
+ your system, open `netdata.conf` and look for the `plugins` setting under `[directories]`.
+
+ ```bash
+ cd /usr/libexec/netdata/plugins.d/
+ ```
+
+- Switch to the `netdata` user.
+
+ ```bash
+ sudo -u netdata -s
+ ```
+
+- Run the `python.d.plugin` to debug the collector:
+
+ ```bash
+ ./python.d.plugin sensors debug trace
+ ```
+
+### lm-sensors doesn't work on your device
+
+
+
+### ACPI ring buffer errors are printed
+
+
+
+