@@ -1,28 +0,0 @@
-### Understand the alert
-
-The `megacli_bbu_cycle_count` alert is related to the battery backup unit (BBU) of your MegaCLI controller. This alert is triggered when the average number of full recharge cycles during the BBU's lifetime exceeds a predefined threshold. High numbers of charge cycles can affect the battery's relative capacity.
-
-A warning state is triggered when the number of charge cycles is greater than 100, and a critical state is triggered when the number of charge cycles is greater than 500.
-
-### Troubleshoot the alert
-
-**Caution:** Before performing any troubleshooting steps, ensure that you have taken the necessary backup measures to protect your data. Netdata is not liable for any data loss or corruption.
-
-1. Gather information about the battery units for all of your adapters:
-
- ```
- megacli -AdpBbuCmd -GetBbuStatus -aALL
- ```
-
-2. Perform a battery check on the BBU with a low relative charge. Before taking any action, consult the manual's[section 7.14](https://docs.broadcom.com/docs/12353236):
-
- ```
- megacli -AdpBbuCmd -BbuLearn -aX // X is the adapter's number
- ```
-
-3. If necessary, replace the battery in question.
-
-### Useful resources
-
-1. [MegaRAID SAS Software User Guide (PDF download)](https://docs.broadcom.com/docs/12353236)
-2. [MegaCLI commands cheatsheet](https://www.broadcom.com/support/knowledgebase/1211161496959/megacli-commands) \ No newline at end of file