diff options
Diffstat (limited to 'src/collectors/charts.d.plugin/apcupsd/metadata.yaml')
-rw-r--r-- | src/collectors/charts.d.plugin/apcupsd/metadata.yaml | 256 |
1 files changed, 0 insertions, 256 deletions
diff --git a/src/collectors/charts.d.plugin/apcupsd/metadata.yaml b/src/collectors/charts.d.plugin/apcupsd/metadata.yaml deleted file mode 100644 index 01d86e795..000000000 --- a/src/collectors/charts.d.plugin/apcupsd/metadata.yaml +++ /dev/null @@ -1,256 +0,0 @@ -plugin_name: charts.d.plugin -modules: - - meta: - plugin_name: charts.d.plugin - module_name: apcupsd - monitored_instance: - name: APC UPS - link: "https://www.apc.com" - categories: - - data-collection.ups - icon_filename: "apc.svg" - related_resources: - integrations: - list: [] - info_provided_to_referring_integrations: - description: "" - keywords: - - ups - - apc - - power - - supply - - battery - - apcupsd - most_popular: false - overview: - data_collection: - metrics_description: "Monitor APC UPS performance with Netdata for optimal uninterruptible power supply operations. Enhance your power supply reliability with real-time APC UPS metrics." - method_description: "The collector uses the `apcaccess` tool to contact the `apcupsd` daemon and get the APC UPS statistics." - supported_platforms: - include: [] - exclude: [] - multi_instance: false - additional_permissions: - description: "" - default_behavior: - auto_detection: - description: "By default, with no configuration provided, the collector will try to contact 127.0.0.1:3551 with using the `apcaccess` utility." - limits: - description: "" - performance_impact: - description: "" - setup: - prerequisites: - list: - - title: "Install charts.d plugin" - description: | - If [using our official native DEB/RPM packages](/packaging/installer/UPDATE.md#determine-which-installation-method-you-used), make sure `netdata-plugin-chartsd` is installed. - - title: "Required software" - description: "Make sure the `apcaccess` and `apcupsd` are installed and running." - configuration: - file: - name: charts.d/apcupsd.conf - options: - description: | - The config file is sourced by the charts.d plugin. It's a standard bash file. - - The following collapsed table contains all the options that can be configured for the apcupsd collector. - folding: - title: "Config options" - enabled: true - list: - - name: apcupsd_sources - description: This is an array of apcupsd sources. You can have multiple entries there. Please refer to the example below on how to set it. - default_value: "127.0.0.1:3551" - required: false - - name: apcupsd_timeout - description: How long to wait for apcupsd to respond. - default_value: 3 - required: false - - name: apcupsd_update_every - description: The data collection frequency. If unset, will inherit the netdata update frequency. - default_value: 1 - required: false - - name: apcupsd_priority - description: The charts priority on the dashboard. - default_value: 90000 - required: false - - name: apcupsd_retries - description: The number of retries to do in case of failure before disabling the collector. - default_value: 10 - required: false - examples: - folding: - enabled: false - title: "Config" - list: - - name: Multiple apcupsd sources - description: Specify a multiple apcupsd sources along with a custom update interval - config: | - # add all your APC UPSes in this array - uncomment it too - declare -A apcupsd_sources=( - ["local"]="127.0.0.1:3551", - ["remote"]="1.2.3.4:3551" - ) - - # how long to wait for apcupsd to respond - #apcupsd_timeout=3 - - # the data collection frequency - # if unset, will inherit the netdata update frequency - apcupsd_update_every=5 - - # the charts priority on the dashboard - #apcupsd_priority=90000 - - # the number of retries to do in case of failure - # before disabling the module - #apcupsd_retries=10 - troubleshooting: - problems: - list: [] - alerts: - - name: apcupsd_ups_charge - link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf - metric: apcupsd.charge - info: average UPS charge over the last minute - os: "*" - - name: apcupsd_10min_ups_load - link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf - metric: apcupsd.load - info: average UPS load over the last 10 minutes - os: "*" - - name: apcupsd_last_collected_secs - link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf - metric: apcupsd.load - info: number of seconds since the last successful data collection - - name: apcupsd_selftest_warning - link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf - metric: apcupsd.selftest - info: self-test failed due to insufficient battery capacity or due to overload. - - name: apcupsd_status_onbatt - link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf - metric: apcupsd.status - info: APC UPS has switched to battery power because the input power has failed - - name: apcupsd_status_overload - link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf - metric: apcupsd.status - info: APC UPS is overloaded and cannot supply enough power to the load - - name: apcupsd_status_lowbatt - link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf - metric: apcupsd.status - info: APC UPS battery is low and needs to be recharged - - name: apcupsd_status_replacebatt - link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf - metric: apcupsd.status - info: APC UPS battery has reached the end of its lifespan and needs to be replaced - - name: apcupsd_status_nobatt - link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf - metric: apcupsd.status - info: APC UPS has no battery - - name: apcupsd_status_commlost - link: https://github.com/netdata/netdata/blob/master/src/health/health.d/apcupsd.conf - metric: apcupsd.status - info: APC UPS communication link is lost - metrics: - folding: - title: Metrics - enabled: false - description: "" - availability: [] - scopes: - - name: ups - description: "Metrics related to UPS. Each UPS provides its own set of the following metrics." - labels: [] - metrics: - - name: apcupsd.charge - description: UPS Charge - unit: "percentage" - chart_type: area - dimensions: - - name: charge - - name: apcupsd.battery.voltage - description: UPS Battery Voltage - unit: "Volts" - chart_type: line - dimensions: - - name: voltage - - name: nominal - - name: apcupsd.input.voltage - description: UPS Input Voltage - unit: "Volts" - chart_type: line - dimensions: - - name: voltage - - name: min - - name: max - - name: apcupsd.output.voltage - description: UPS Output Voltage - unit: "Volts" - chart_type: line - dimensions: - - name: absolute - - name: nominal - - name: apcupsd.input.frequency - description: UPS Input Voltage - unit: "Hz" - chart_type: line - dimensions: - - name: frequency - - name: apcupsd.load - description: UPS Load - unit: "percentage" - chart_type: area - dimensions: - - name: load - - name: apcupsd.load_usage - description: UPS Load Usage - unit: "Watts" - chart_type: area - dimensions: - - name: load - - name: apcupsd.temperature - description: UPS Temperature - unit: "Celsius" - chart_type: line - dimensions: - - name: temp - - name: apcupsd.time - description: UPS Time Remaining - unit: "Minutes" - chart_type: area - dimensions: - - name: time - - name: apcupsd.online - description: UPS ONLINE flag - unit: "boolean" - chart_type: line - dimensions: - - name: online - - name: apcupsd.selftest - description: UPS Self-Test status - unit: status - chart_type: line - dimensions: - - name: OK - - name: NO - - name: BT - - name: NG - - name: apcupsd.status - description: UPS Status - unit: status - chart_type: line - dimensions: - - name: ONLINE - - name: ONBATT - - name: OVERLOAD - - name: LOWBATT - - name: REPLACEBATT - - name: NOBATT - - name: SLAVE - - name: SLAVEDOWN - - name: COMMLOST - - name: CAL - - name: TRIM - - name: BOOST - - name: SHUTTING_DOWN |