diff options
Diffstat (limited to 'src/collectors/python.d.plugin/alarms/alarms.conf')
-rw-r--r-- | src/collectors/python.d.plugin/alarms/alarms.conf | 60 |
1 files changed, 0 insertions, 60 deletions
diff --git a/src/collectors/python.d.plugin/alarms/alarms.conf b/src/collectors/python.d.plugin/alarms/alarms.conf deleted file mode 100644 index 06d76c3b3..000000000 --- a/src/collectors/python.d.plugin/alarms/alarms.conf +++ /dev/null @@ -1,60 +0,0 @@ -# netdata python.d.plugin configuration for example -# -# This file is in YaML format. Generally the format is: -# -# name: value -# -# There are 2 sections: -# - global variables -# - one or more JOBS -# -# JOBS allow you to collect values from multiple sources. -# Each source will have its own set of charts. -# -# JOB parameters have to be indented (using spaces only, example below). - -# ---------------------------------------------------------------------- -# Global Variables -# These variables set the defaults for all JOBs, however each JOB -# may define its own, overriding the defaults. - -# update_every sets the default data collection frequency. -# If unset, the python.d.plugin default is used. -# update_every: 10 - -# priority controls the order of charts at the netdata dashboard. -# Lower numbers move the charts towards the top of the page. -# If unset, the default for python.d.plugin is used. -# priority: 60000 - -# penalty indicates whether to apply penalty to update_every in case of failures. -# Penalty will increase every 5 failed updates in a row. Maximum penalty is 10 minutes. -# penalty: yes - -# autodetection_retry sets the job re-check interval in seconds. -# The job is not deleted if check fails. -# Attempts to start the job are made once every autodetection_retry. -# This feature is disabled by default. -# autodetection_retry: 0 - -# ---------------------------------------------------------------------- -# JOBS (data collection sources) - -# what url to pull data from -local: - url: 'http://127.0.0.1:19999/api/v1/alarms?all' - # define how to map alarm status to numbers for the chart - status_map: - CLEAR: 0 - WARNING: 1 - CRITICAL: 2 - # set to true to include a chart with calculated alarm values over time - collect_alarm_values: false - # define the type of chart for plotting status over time e.g. 'line' or 'stacked' - alarm_status_chart_type: 'line' - # a "," separated list of words you want to filter alarm names for. For example 'cpu,load' would filter for only - # alarms with "cpu" or "load" in alarm name. Default includes all. - alarm_contains_words: '' - # a "," separated list of words you want to exclude based on alarm name. For example 'cpu,load' would exclude - # all alarms with "cpu" or "load" in alarm name. Default excludes None. - alarm_excludes_words: '' |