blob: 9b41a8fd67ba9752a84d3a8d8b3df59368d9c184 (
plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
|
<!--startmeta
custom_edit_url: "https://github.com/netdata/netdata/edit/master/collectors/python.d.plugin/am2320/README.md"
meta_yaml: "https://github.com/netdata/netdata/edit/master/collectors/python.d.plugin/am2320/metadata.yaml"
sidebar_label: "AM2320"
learn_status: "Published"
learn_rel_path: "Data Collection/Hardware Devices and Sensors"
message: "DO NOT EDIT THIS FILE DIRECTLY, IT IS GENERATED BY THE COLLECTOR'S metadata.yaml FILE"
endmeta-->
# AM2320
<img src="https://netdata.cloud/img/microchip.svg" width="150"/>
Plugin: python.d.plugin
Module: am2320
<img src="https://img.shields.io/badge/maintained%20by-Netdata-%2300ab44" />
## Overview
This collector monitors AM2320 sensor metrics about temperature and humidity.
It retrieves temperature and humidity values by contacting an AM2320 sensor over i2c.
This collector is supported on all platforms.
This collector only supports collecting metrics from a single instance of this integration.
### Default Behavior
#### Auto-Detection
Assuming prerequisites are met, the collector will try to connect to the sensor via i2c
#### Limits
The default configuration for this integration does not impose any limits on data collection.
#### Performance Impact
The default configuration for this integration is not expected to impose a significant performance impact on the system.
## Metrics
Metrics grouped by *scope*.
The scope defines the instance that the metric belongs to. An instance is uniquely identified by a set of labels.
### Per AM2320 instance
These metrics refer to the entire monitored application.
This scope has no labels.
Metrics:
| Metric | Dimensions | Unit |
|:------|:----------|:----|
| am2320.temperature | temperature | celsius |
| am2320.humidity | humidity | percentage |
## Alerts
There are no alerts configured by default for this integration.
## Setup
### Prerequisites
#### Sensor connection to a Raspberry Pi
Connect the am2320 to the Raspberry Pi I2C pins
Raspberry Pi 3B/4 Pins:
- Board 3.3V (pin 1) to sensor VIN (pin 1)
- Board SDA (pin 3) to sensor SDA (pin 2)
- Board GND (pin 6) to sensor GND (pin 3)
- Board SCL (pin 5) to sensor SCL (pin 4)
You may also need to add two I2C pullup resistors if your board does not already have them. The Raspberry Pi does have internal pullup resistors but it doesn't hurt to add them anyway. You can use 2.2K - 10K but we will just use 10K. The resistors go from VDD to SCL and SDA each.
#### Software requirements
Install the Adafruit Circuit Python AM2320 library:
`sudo pip3 install adafruit-circuitpython-am2320`
### Configuration
#### File
The configuration file name for this integration is `python.d/am2320.conf`.
You can edit the configuration file using the `edit-config` script from the
Netdata [config directory](https://github.com/netdata/netdata/blob/master/docs/configure/nodes.md#the-netdata-config-directory).
```bash
cd /etc/netdata 2>/dev/null || cd /opt/netdata/etc/netdata
sudo ./edit-config python.d/am2320.conf
```
#### Options
There are 2 sections:
* Global variables
* One or more JOBS that can define multiple different instances to monitor.
The following options can be defined globally: priority, penalty, autodetection_retry, update_every, but can also be defined per JOB to override the global values.
Additionally, the following collapsed table contains all the options that can be configured inside a JOB definition.
Every configuration JOB starts with a `job_name` value which will appear in the dashboard, unless a `name` parameter is specified.
<details><summary>Config options</summary>
| Name | Description | Default | Required |
|:----|:-----------|:-------|:--------:|
| update_every | Sets the default data collection frequency. | 5 | False |
| priority | Controls the order of charts at the netdata dashboard. | 60000 | False |
| autodetection_retry | Sets the job re-check interval in seconds. | 0 | False |
| penalty | Indicates whether to apply penalty to update_every in case of failures. | yes | False |
| name | Job name. This value will overwrite the `job_name` value. JOBS with the same name are mutually exclusive. Only one of them will be allowed running at any time. This allows autodetection to try several alternatives and pick the one that works. | | False |
</details>
#### Examples
##### Local sensor
A basic JOB configuration
```yaml
local_sensor:
name: 'Local AM2320'
```
## Troubleshooting
### Debug Mode
To troubleshoot issues with the `am2320` collector, run the `python.d.plugin` with the debug option enabled. The output
should give you clues as to why the collector isn't working.
- Navigate to the `plugins.d` directory, usually at `/usr/libexec/netdata/plugins.d/`. If that's not the case on
your system, open `netdata.conf` and look for the `plugins` setting under `[directories]`.
```bash
cd /usr/libexec/netdata/plugins.d/
```
- Switch to the `netdata` user.
```bash
sudo -u netdata -s
```
- Run the `python.d.plugin` to debug the collector:
```bash
./python.d.plugin am2320 debug trace
```
|