blob: 7b0768237184bf728b2b4d00d7896ff2c133637c (
plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
|
plugin_name: python.d.plugin
modules:
- meta:
plugin_name: python.d.plugin
module_name: w1sensor
monitored_instance:
name: 1-Wire Sensors
link: "https://www.analog.com/en/product-category/1wire-temperature-sensors.html"
categories:
- data-collection.hardware-devices-and-sensors
icon_filename: "1-wire.png"
related_resources:
integrations:
list: []
info_provided_to_referring_integrations:
description: ""
keywords:
- temperature
- sensor
- 1-wire
most_popular: false
overview:
data_collection:
metrics_description: "Monitor 1-Wire Sensors metrics with Netdata for optimal environmental conditions monitoring. Enhance your environmental monitoring with real-time insights and alerts."
method_description: "The collector uses the wire, w1_gpio, and w1_therm kernel modules. Currently temperature sensors are supported and automatically detected."
supported_platforms:
include:
- Linux
exclude: []
multi_instance: true
additional_permissions:
description: ""
default_behavior:
auto_detection:
description: "The collector will try to auto detect available 1-Wire devices."
limits:
description: ""
performance_impact:
description: ""
setup:
prerequisites:
list:
- title: "Required Linux kernel modules"
description: "Make sure `wire`, `w1_gpio`, and `w1_therm` kernel modules are loaded."
configuration:
file:
name: python.d/w1sensor.conf
options:
description: |
There are 2 sections:
* Global variables
* One or more JOBS that can define multiple different instances to monitor.
The following options can be defined globally: priority, penalty, autodetection_retry, update_every, but can also be defined per JOB to override the global values.
Additionally, the following collapsed table contains all the options that can be configured inside a JOB definition.
Every configuration JOB starts with a `job_name` value which will appear in the dashboard, unless a `name` parameter is specified.
folding:
title: "Config options"
enabled: true
list:
- name: update_every
description: Sets the default data collection frequency.
default_value: 5
required: false
- name: priority
description: Controls the order of charts at the netdata dashboard.
default_value: 60000
required: false
- name: autodetection_retry
description: Sets the job re-check interval in seconds.
default_value: 0
required: false
- name: penalty
description: Indicates whether to apply penalty to update_every in case of failures.
default_value: yes
required: false
- name: name
description: Job name. This value will overwrite the `job_name` value. JOBS with the same name are mutually exclusive. Only one of them will be allowed running at any time. This allows autodetection to try several alternatives and pick the one that works.
default_value: ""
required: false
- name: name_<1-Wire id>
description: This allows associating a human readable name with a sensor's 1-Wire identifier.
default_value: ""
required: false
examples:
folding:
enabled: false
title: "Config"
list:
- name: Provide human readable names
description: Associate two 1-Wire identifiers with human readable names.
config: |
sensors:
name_00000022276e: 'Machine room'
name_00000022298f: 'Rack 12'
troubleshooting:
problems:
list: []
alerts: []
metrics:
folding:
title: Metrics
enabled: false
description: ""
availability: []
scopes:
- name: global
description: "These metrics refer to the entire monitored application."
labels: []
metrics:
- name: w1sensor.temp
description: 1-Wire Temperature Sensor
unit: "Celsius"
chart_type: line
dimensions:
- name: a dimension per sensor
|