summaryrefslogtreecommitdiffstats
path: root/src/collectors/freeipmi.plugin/metadata.yaml
blob: a0f4d2800cd467c60ac251c8acbfce5732edfef0 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
plugin_name: freeipmi.plugin
modules:
  - meta:
      plugin_name: freeipmi.plugin
      module_name: freeipmi
      monitored_instance:
        name: Intelligent Platform Management Interface (IPMI)
        link: "https://en.wikipedia.org/wiki/Intelligent_Platform_Management_Interface"
        categories:
          - data-collection.hardware-devices-and-sensors
        icon_filename: "netdata.png"
      related_resources:
        integrations:
          list: []
      info_provided_to_referring_integrations:
        description: ""
      keywords:
        - sensors
        - ipmi
        - freeipmi
        - ipmimonitoring
      most_popular: true
    overview:
      data_collection:
        metrics_description: |
          "Monitor enterprise server sensor readings, event log entries, and hardware statuses to ensure reliable server operations."
        method_description: |
          The plugin uses open source library IPMImonitoring to communicate with sensors.
      supported_platforms:
        include: []
        exclude: []
      multi_instance: true
      additional_permissions:
        description: "The plugin needs setuid."
      default_behavior:
        auto_detection:
          description: ""
        limits:
          description: ""
        performance_impact:
          description: "Linux kernel module for IPMI can create big overhead."
    setup:
      prerequisites:
        list:
          - title: Install freeipmi.plugin
            description: |
              When using our official DEB/RPM packages, the FreeIPMI plugin is included in a separate package named `netdata-plugin-freeipmi` which needs to be manually installed using your system package manager. It is not installed automatically due to the large number of dependencies it requires.

              When using a static build of Netdata, the FreeIPMI plugin will be included and installed automatically, though you will still need to have FreeIPMI installed on your system to be able to use the plugin.

              When using a local build of Netdata, you need to ensure that the FreeIPMI development packages (typically called `libipmimonitoring-dev`, `libipmimonitoring-devel`, or `freeipmi-devel`) are installed when building Netdata.
          - title: Preliminary actions
            description: |
              If you have not previously used IPMI on your system, you will probably need to run the `ipmimonitoring` command as root
              to initialize IPMI settings so that the Netdata plugin works correctly. It should return information about available sensors on the system.
      configuration:
        file:
          name: "netdata.conf"
          section_name: "[plugin:freeipmi]"
        options:
          description: |
            The configuration is set using command line options:

            ```
            # netdata.conf
            [plugin:freeipmi]
              command options = opt1 opt2 ... optN
            ```

            To display a help message listing the available command line options:

            ```bash
            ./usr/libexec/netdata/plugins.d/freeipmi.plugin --help
            ```
          folding:
            title: "Command options"
            enabled: true
          list:
            - name: SECONDS
              description: Data collection frequency.
              default_value: ""
              required: false
            - name: debug
              description: Enable verbose output.
              default_value: disabled
              required: false
            - name: no-sel
              description: Disable System Event Log (SEL) collection.
              default_value: disabled
              required: false
            - name: reread-sdr-cache
              description: Re-read SDR cache on every iteration.
              default_value: disabled
              required: false
            - name: interpret-oem-data
              description: Attempt to parse OEM data.
              default_value: disabled
              required: false
            - name: assume-system-event-record
              description: treat illegal SEL events records as normal.
              default_value: disabled
              required: false
            - name: ignore-non-interpretable-sensors
              description: Do not read sensors that cannot be interpreted.
              default_value: disabled
              required: false
            - name: bridge-sensors
              description: Bridge sensors not owned by the BMC.
              default_value: disabled
              required: false
            - name: shared-sensors
              description: Enable shared sensors if found.
              default_value: disabled
              required: false
            - name: no-discrete-reading
              description: Do not read sensors if their event/reading type code is invalid.
              default_value: enabled
              required: false
            - name: ignore-scanning-disabled
              description: Ignore the scanning bit and read sensors no matter what.
              default_value: disabled
              required: false
            - name: assume-bmc-owner
              description: Assume the BMC is the sensor owner no matter what (usually bridging is required too).
              default_value: disabled
              required: false
            - name: hostname HOST
              description: Remote IPMI hostname or IP address.
              default_value: local
              required: false
            - name: username USER
              description: Username that will be used when connecting to the remote host.
              default_value: ""
              required: false
            - name: password PASS
              description: Password that will be used when connecting to the remote host.
              default_value: ""
              required: false
            - name: noauthcodecheck / no-auth-code-check
              description: Don't check the authentication codes returned.
              default_value: ""
              required: false
            - name: driver-type IPMIDRIVER
              description: Specify the driver type to use instead of doing an auto selection. The currently available outofband drivers are LAN and LAN_2_0, which  perform  IPMI  1.5  and  IPMI  2.0 respectively. The currently available inband drivers are KCS, SSIF, OPENIPMI and SUNBMC.
              default_value: ""
              required: false
            - name: sdr-cache-dir PATH
              description: SDR cache files directory.
              default_value: /tmp
              required: false
            - name: sensor-config-file FILE
              description: Sensors configuration filename.
              default_value: system default
              required: false
            - name: sel-config-file FILE
              description: SEL configuration filename.
              default_value: system default
              required: false
            - name: ignore N1,N2,N3,...
              description: Sensor IDs to ignore.
              default_value: ""
              required: false
            - name: ignore-status N1,N2,N3,...
              description: Sensor IDs to ignore status (nominal/warning/critical).
              default_value: ""
              required: false
            - name: -v
              description: Print version and exit.
              default_value: ""
              required: false
            - name: --help
              description: Print usage message and exit.
              default_value: ""
              required: false
        examples:
          folding:
            enabled: true
            title: "Config"
          list:
            - name: Decrease data collection frequency
              description: Basic example decreasing data collection frequency. The minimum `update every` is 5 (enforced internally by the plugin). IPMI is slow and CPU hungry. So, once every 5 seconds is pretty acceptable.
              config: |
                [plugin:freeipmi]
                  update every = 10
              folding:
                enabled: false
            - name: Disable SEL collection
              description: Append to `command options =` the options you need.
              config: |
                [plugin:freeipmi]
                  command options = no-sel
            - name: Ignore specific sensors
              description: |
                Specific sensor IDs can be excluded from freeipmi tools by editing `/etc/freeipmi/freeipmi.conf` and setting the IDs to be ignored at `ipmi-sensors-exclude-record-ids`.

                **However this file is not used by `libipmimonitoring`** (the library used by Netdata's `freeipmi.plugin`).

                To find the IDs to ignore, run the command `ipmimonitoring`. The first column is the wanted ID:

                ID  | Name             | Type                     | State    | Reading    | Units | Event
                1   | Ambient Temp     | Temperature              | Nominal  | 26.00      | C     | 'OK'
                2   | Altitude         | Other Units Based Sensor | Nominal  | 480.00     | ft    | 'OK'
                3   | Avg Power        | Current                  | Nominal  | 100.00     | W     | 'OK'
                4   | Planar 3.3V      | Voltage                  | Nominal  | 3.29       | V     | 'OK'
                5   | Planar 5V        | Voltage                  | Nominal  | 4.90       | V     | 'OK'
                6   | Planar 12V       | Voltage                  | Nominal  | 11.99      | V     | 'OK'
                7   | Planar VBAT      | Voltage                  | Nominal  | 2.95       | V     | 'OK'
                8   | Fan 1A Tach      | Fan                      | Nominal  | 3132.00    | RPM   | 'OK'
                9   | Fan 1B Tach      | Fan                      | Nominal  | 2150.00    | RPM   | 'OK'
                10  | Fan 2A Tach      | Fan                      | Nominal  | 2494.00    | RPM   | 'OK'
                11  | Fan 2B Tach      | Fan                      | Nominal  | 1825.00    | RPM   | 'OK'
                12  | Fan 3A Tach      | Fan                      | Nominal  | 3538.00    | RPM   | 'OK'
                13  | Fan 3B Tach      | Fan                      | Nominal  | 2625.00    | RPM   | 'OK'
                14  | Fan 1            | Entity Presence          | Nominal  | N/A        | N/A   | 'Entity Present'
                15  | Fan 2            | Entity Presence          | Nominal  | N/A        | N/A   | 'Entity Present'
                ...

                `freeipmi.plugin` supports the option `ignore` that accepts a comma separated list of sensor IDs to ignore. To configure it set on `netdata.conf`:
              config: |
                [plugin:freeipmi]
                      command options = ignore 1,2,3,4,...
    troubleshooting:
      problems:
        list:
          - name: Debug Mode
            description: |
              You can run `freeipmi.plugin` with the debug option enabled, to troubleshoot issues with it. The output should give you clues as to why the collector isn't working.

              - Navigate to the `plugins.d` directory, usually at `/usr/libexec/netdata/plugins.d/`. If that's not the case on your system, open `netdata.conf` and look for the `plugins` setting under `[directories]`.

                ```bash
                cd /usr/libexec/netdata/plugins.d/
                ```

              - Switch to the `netdata` user.

                ```bash
                sudo -u netdata -s
                ```

              - Run the `freeipmi.plugin` in debug mode:

                ```bash
                ./freeipmi.plugin 5 debug
                ```
          - name: kimpi0 CPU usage
            description: |
              There have been reports that kipmi is showing increased CPU when the IPMI is queried. To lower the CPU consumption of the system you can issue this command:

              ```sh
              echo 10 > /sys/module/ipmi_si/parameters/kipmid_max_busy_us
              ```

              You can also permanently set the above setting by creating the file `/etc/modprobe.d/ipmi.conf` with this content:

              ```sh
              # prevent kipmi from consuming 100% CPU
              options ipmi_si kipmid_max_busy_us=10
              ```

              This instructs the kernel IPMI module to pause for a tick between checking IPMI. Querying IPMI will be a lot slower now (e.g. several seconds for IPMI to respond), but `kipmi` will not use any noticeable CPU.

              You can also use a higher number (this is the number of microseconds to poll IPMI for a response, before waiting for a tick).
    alerts:
      - name: ipmi_sensor_state
        link: https://github.com/netdata/netdata/blob/master/src/health/health.d/ipmi.conf
        metric: ipmi.sensor_state
        info: IPMI sensor ${label:sensor} (${label:component}) state
    metrics:
      folding:
        title: Metrics
        enabled: false
      description: |
        The plugin does a speed test when it starts, to find out the duration needed by the IPMI processor to respond. Depending on the speed of your IPMI processor, charts may need several seconds to show up on the dashboard.
      availability: []
      scopes:
        - name: global
          description: These metrics refer to the entire monitored application.
          labels: []
          metrics:
            - name: ipmi.sel
              description: IPMI Events
              unit: "events"
              chart_type: area
              dimensions:
                - name: events
        - name: sensor
          description: ""
          labels:
            - name: sensor
              description: The sensor name
            - name: type
              description: One of 45 recognized sensor types (Battery, Voltage...)
            - name: component
              description: One of 25 recognized components (Processor, Peripheral).
          metrics:
            - name: ipmi.sensor_state
              description: IPMI Sensors State
              unit: "state"
              chart_type: line
              dimensions:
                - name: nominal
                - name: critical
                - name: warning
                - name: unknown
            - name: ipmi.sensor_temperature_c
              description: IPMI Sensor Temperature Celsius
              unit: "Celsius"
              chart_type: line
              dimensions:
                - name: temperature
            - name: ipmi.sensor_temperature_f
              description: IPMI Sensor Temperature Fahrenheit
              unit: "Fahrenheit"
              chart_type: line
              dimensions:
                - name: temperature
            - name: ipmi.sensor_voltage
              description: IPMI Sensor Voltage
              unit: "Volts"
              chart_type: line
              dimensions:
                - name: voltage
            - name: ipmi.sensor_ampere
              description: IPMI Sensor Current
              unit: "Amps"
              chart_type: line
              dimensions:
                - name: ampere
            - name: ipmi.sensor_fan_speed
              description: IPMI Sensor Fans Speed
              unit: "RPM"
              chart_type: line
              dimensions:
                - name: rotations
            - name: ipmi.sensor_power
              description: IPMI Sensor Power
              unit: "Watts"
              chart_type: line
              dimensions:
                - name: power
            - name: ipmi.sensor_reading_percent
              description: IPMI Sensor Reading Percentage
              unit: "%"
              chart_type: line
              dimensions:
                - name: percentage