1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
|
nvme-compare(1)
===============
NAME
----
nvme-compare - Send an NVMe Compare command, provide results
SYNOPSIS
--------
[verse]
'nvme-compare' <device> [--start-block=<slba> | -s <slba>]
[--block-count=<nlb> | -c <nlb>]
[--data-size=<size> | -z <size>]
[--metadata-size=<metasize> | -y <metasize>]
[--ref-tag=<reftag> | -r <reftag>]
[--data=<data-file> | -d <data-file>]
[--metadata=<meta> | -M <meta>]
[--prinfo=<prinfo> | -p <prinfo>]
[--app-tag-mask=<appmask> | -m <appmask>]
[--app-tag=<apptag> | -a <apptag>]
[--limited-retry | -l]
[--force-unit-access | -f]
[--dir-type=<type> | -T <type>]
[--dir-spec=<spec> | -S <spec>]
[--dsm=<dsm> | -D <dsm>]
[--show-command | -v]
[--dry-run | -w]
[--latency | -t]
[--storage-tag<storage-tag> | -g <storage-tag>]
[--storage-tag-check<storage-tag-check> | -C <storage-tag-check>]
[--force]
DESCRIPTION
-----------
The Compare command reads the logical blocks specified by the command
from the medium and compares the data read to a comparison data buffer
transferred as part of the command. If the data read from the controller
and the comparison data buffer are equivalent with no miscompares,
then the command completes successfully. If there is any miscompare,
the command completes with an error of Compare Failure. If metadata is
provided, then a comparison is also performed for the metadata.
OPTIONS
-------
-s <slba>::
--start-block=<slba>::
64-bit address of the first block to access.
-c <nlb>::
--block-count=<nlb>::
Number of blocks to be accessed (zero-based).
-z <size>::
--data-size=<size>::
Size of data to be compared in bytes.
-y <metasize>::
--metadata-size=<metasize>::
Size of metadata to be transferred in bytes.
-r <reftag>::
--ref-tag=<reftag>::
Reference Tag for Protection Information
-d <data-file>::
--data=<data-file>::
Data file.
-M <meta>::
--metadata=<meta>::
Metadata file.
-p <prinfo>::
--prinfo=<prinfo>::
Protection Information and check field.
+
[]
|=================
|Bit|Description
|3|PRACT: Protection Information Action. When set to 1, PI is stripped/inserted
on read/write when the block format's metadata size is 8. When set to 0,
metadata is passes.
|2:0|PRCHK: Protection Information Check:
|2|Set to 1 enables checking the guard tag
|1|Set to 1 enables checking the application tag
|0|Set to 1 enables checking the reference tag
|=================
-m <appmask>::
--app-tag-mask=<appmask>::
App Tag Mask for Protection Information
-a <apptag>::
--app-tag=<apptag>::
App Tag for Protection Information
-l::
--limited-retry::
Number of limited attempts to media.
-f::
--force-unit-access::
FUA option to guarantee that data is stored to media.
-T <type>::
--dir-type=<type>::
Optional directive type. The nvme-cli only enforces the value
be in the defined range for the directive type, though the NVMe
specification (1.3a) defines only one directive, 01h, for write
stream identifiers.
-S <spec>::
--dir-spec=<spec>::
Optional field for directive specifics. When used with
write streams, this value is defined to be the write stream
identifier. The nvme-cli will not validate the stream requested
is within the controller's capabilities.
-D <dsm>::
--dsm=<dsm>::
The optional data set management attributes for this command. The argument
for this is the least significant 8 bits of the DSM field in a write
command; the most significant 16 bits of the field come from the directive
specific field, if used. This may be used to set attributes for
the LBAs being written, like access frequency, type, latency,
among other things, as well as yet to be defined types. Please
consult the NVMe specification for detailed breakdown of how to
use this field.
-v::
--show-cmd::
Print out the command to be sent.
-w::
--dry-run::
Do not actually send the command. If want to use --dry-run option,
--show-cmd option _must_ be set. Otherwise --dry-run option will be
_ignored_.
-t::
--latency::
Print out the latency the IOCTL took (in us).
--storage-tag=<storage-tag>::
-g <storage-tag>::
Variable Sized Expected Logical Block Storage Tag(ELBST).
--storage-tag-check=<storage-tag-check>::
-C <storage-tag-check>::
This bit specifies the Storage Tag field shall be checked as part of end-to-end
data protection processing.
--force::
Ignore namespace is currently busy and performed the operation
even though.
EXAMPLES
--------
No examples yet.
NVME
----
Part of the nvme-user suite
|