+<varlistentry>
+ <term><option>-h</option></term>
+ <term><option>--help</option></term>
+ <listitem>
+ <simpara>Print a short help message describing command line
+ options to standard output and exit</simpara>
+ </listitem>
+</varlistentry>
+
+<varlistentry>
+ <term><option>--version</option></term>
+ <listitem>
+ <simpara>Print program version information to standard output and
+ exit</simpara>
+ </listitem>
+</varlistentry>
+
+<varlistentry>
+ <term><option>-v</option></term>
+ <term><option>--verbose<optional>=<replaceable
+ class="parameter">n</replaceable></optional></option></term>
+ <listitem>
+ <simpara>Increase debug output level. Multiple
+ <option>-v</option> options create more spew. Alternatively
+ specify <replaceable class="parameter">n</replaceable> to
+ set the debug level directly
+ </simpara>
+ </listitem>
+</varlistentry>
+
+<varlistentry>
+ <term><option>-S<optional><replaceable
+ class="parameter">symbology</replaceable>.</optional><replaceable
+ class="parameter">config</replaceable><optional>=<replaceable
+ class="parameter">value</replaceable></optional></option></term>
+ <term><option>--set <optional><replaceable
+ class="parameter">symbology</replaceable>.</optional><replaceable
+ class="parameter">config</replaceable><optional>=<replaceable
+ class="parameter">value</replaceable></optional></option></term>
+ <listitem>
+ <simpara>Set decoder configuration option <replaceable
+ class="parameter">config</replaceable> for <replaceable
+ class="parameter">symbology</replaceable> to <replaceable
+ class="parameter">value</replaceable>. <replaceable
+ class="parameter">value</replaceable> defaults to 1 if omitted.
+ <replaceable class="parameter">symbology</replaceable> is one of
+ <option>ean13</option>, <option>ean8</option>,
+ <option>upca</option>, <option>upce</option>,
+ <option>isbn13</option>, <option>isbn10</option>,
+ <option>i25</option>, <option>codabar</option>, <option>code39</option>,
+ <option>code93</option>, <option>code128</option>,
+ <option>qrcode</option> or the special value <option>*</option>.
+ If <replaceable class="parameter">symbology</replaceable> is
+ omitted or <option>*</option>, the <replaceable
+ class="parameter">config</replaceable> will be set for all
+ applicable symbologies. These are the currently recognized
+ <replaceable class="parameter">config</replaceable>s. Prefix a
+ config with "no-" to negate it. Not all configs are appropriate
+ for every symbology.</simpara>
+
+ <variablelist>
+ <varlistentry>
+ <term><option>enable</option></term>
+ <listitem>
+ <simpara>Control decoding/reporting of a symbology. For
+ symbologies which are just subsets of <option>ean13</option>
+ (<option>upca</option>, <option>upce</option>,
+ <option>isbn13</option>, <option>isbn10</option>), this
+ config controls whether the subsets are detected and
+ reported as such. These special cases are disabled by
+ default, all other symbologies default to enabled</simpara>
+ </listitem>
+ </varlistentry>
+
+ <varlistentry>
+ <term><option>disable</option></term>
+ <listitem>
+ <simpara>Antonym for <option>enable</option></simpara>
+ </listitem>
+ </varlistentry>
+
+ <varlistentry>
+ <term><option>emit-check</option></term>
+ <listitem>
+ <simpara>Control whether check digits are included in the
+ decoded output. Enabled by default. This config does not
+ apply for <option>code128</option>, which never returns the
+ check digit. It also not apply for cases where the check
+ digit is disabled (see <option>add-check</option>). Check
+ digits are currently not implemented for
+ <option>i25</option> or <option>code39</option></simpara>
+ </listitem>
+ </varlistentry>
+
+ <varlistentry>
+ <term><option>add-check</option></term>
+ <listitem>
+ <simpara>Enable decode and verification of a check digit for
+ symbologies where it is optional: this will include
+ <option>code39</option> and <option>i25</option>, neither of
+ which implements the check digit yet</simpara>
+ </listitem>
+ </varlistentry>
+
+ <varlistentry>
+ <term><option>ascii</option></term>
+ <listitem>
+ <simpara>Enable escape sequences that encode the full ASCII
+ character set. This would apply to <option>code39</option>,
+ except that it's not implemented either...</simpara>
+ </listitem>
+ </varlistentry>
+
+ <varlistentry>
+ <term><option>position</option></term>
+ <listitem>
+ <simpara>Enable collection of symbol position information.
+ Enabled by default. Currently, the position information is
+ unusable, so you can save a few cycles by disabling
+ this.</simpara>
+ </listitem>
+ </varlistentry>
+
+ <varlistentry>
+ <term><option>test-inverted</option></term>
+ <listitem>
+ <simpara>Specially for QR code images, sometimes the image
+ is inverted, e. g. lines are written in white instead of black.
+ This option makes ZBar to invert the image and parse again, in
+ case it fails using the normal order. Enabling it affects all
+ decoders.</simpara>
+ </listitem>
+ </varlistentry>
+
+ <varlistentry>
+ <term><option>min-length=<replaceable class="parameter">n</replaceable></option></term>
+ <term><option>max-length=<replaceable class="parameter">n</replaceable></option></term>
+ <listitem>
+ <simpara>Bound the number of decoded characters in a valid symbol.
+ If a decode result is outside the configured min/max range
+ (inclusive), it will not be reported. Set to 0 to disable the
+ corresponding check. This setting applies to variable-length
+ symbologies: <option>i25</option>, <option>codabar</option>,
+ <option>code39</option>, <option>code128</option> and
+ <option>pdf417</option>. <option>min-length</option> defaults to 6
+ for <option>i25</option> and 1 for <option>code39</option> (per Code
+ 39 autodiscrimination recommendation); all others default to
+ 0</simpara>
+ </listitem>
+ </varlistentry>
+
+ <varlistentry>
+ <term><option>x-density=<replaceable class="parameter">n</replaceable></option></term>
+ <term><option>y-density=<replaceable class="parameter">n</replaceable></option></term>
+ <listitem>
+ <simpara>Adjust the density of the scanner passes. Lower values
+ scan more of the image at the cost of decreased performance.
+ Setting to 0 disables scanning along that axis. Defaults are both
+ 1.</simpara>
+ </listitem>
+ </varlistentry>
+ </variablelist>
+
+ </listitem>
+</varlistentry>